Assessment of fatigability of older women during sit-to-stand performance

BackgroundFatigability of older adults is relevant with regard to physical performance, falls and physical activity. Objective and inexpensive assessment tools for testing fatigability in the persons’ home environment are not available.AimsThe aim of this study was to develop a protocol to objectively measure fatigability during repeated sit-to-stand performance in older persons.MethodsDecrease of maximum velocity of performance during repeated sit-to-stand transfers and the number of repetition when achieving a 10, 15, and 20 % fatigue threshold were measured in 49 community-dwelling older women using a linear encoder.ResultsMean maximum velocity of the sit-to-stand performance was 1.12 m/s (SD 0.17 m/s) with an estimated change of velocity per repetition of −0.0037 m/s (95 % CI −0.0039 to −0.0035) during the test. The mean number of repetitions representing 10, 15, and 20 % fatigue threshold was 8.1, 13.8, and 21, respectively.DiscussionThis simple test protocol provides objective information about the decrease of performance of a daily task in older adults.ConclusionFatigability of the sit-to-stand performance can be measured objectively by measuring the decrease of maximum velocity of consecutive repetitions and the repetition number achieving a 20 % fatigue threshold.

[1]  M. Gray,et al.  Developing a measure of muscular power during a functional task for older adults , 2014, BMC Geriatrics.

[2]  L Chiari,et al.  Automated approach for quantifying the repeated sit-to-stand using one body fixed sensor in young and older adults. , 2013, Gait & posture.

[3]  W. Evans,et al.  Physiological Basis of Fatigue , 2007, American journal of physical medicine & rehabilitation.

[4]  Ulrich Lindemann,et al.  Effect of bed height and use of hands on trunk angular velocity during the sit-to-stand transfer , 2014, Ergonomics.

[5]  M. Mancini,et al.  Sit-stand and stand-sit transitions in older adults and patients with Parkinson’s disease: event detection based on motion sensors versus force plates , 2012, Journal of NeuroEngineering and Rehabilitation.

[6]  C. Becker,et al.  Validity of linear encoder measurement of sit-to-stand performance power in older people. , 2015, Physiotherapy.

[7]  M. Tinetti,et al.  Risk factors for falls among elderly persons living in the community. , 1988, The New England journal of medicine.

[8]  Christianna S. Williams,et al.  Restricted Activity among Community-Living Older Persons: Incidence, Precipitants, and Health Care Utilization , 2001, Annals of Internal Medicine.

[9]  A. Newman,et al.  The Pittsburgh Fatigability Scale for Older Adults: Development and Validation , 2015, Journal of the American Geriatrics Society.

[10]  W. Beam,et al.  A 30-s chair-stand test as a measure of lower body strength in community-residing older adults. , 1999, Research quarterly for exercise and sport.

[11]  Mirjam Pijnappels,et al.  Consequences of lower extremity and trunk muscle fatigue on balance and functional tasks in older people: A systematic literature review , 2010, BMC geriatrics.

[12]  R. Moe-Nilssen,et al.  Physical fatigue affects gait characteristics in older persons. , 2007, The journals of gerontology. Series A, Biological sciences and medical sciences.

[13]  John B Cronin,et al.  Reliability and Validity of a Linear Position Transducer for Measuring Jump Performance , 2004, Journal of strength and conditioning research.

[14]  Roger M Enoka,et al.  Fatigue and fatigability in neurologic illnesses , 2013, Neurology.

[15]  Maury A Nussbaum,et al.  Effects of localized muscle fatigue on recovery from a postural perturbation without stepping. , 2009, Gait & posture.

[16]  L. Ferrucci,et al.  Assessing Fatigability in Mobility‐Intact Older Adults , 2014, Journal of the American Geriatrics Society.