Safety and Efficacy of Bipolar Radiofrequency Ablation Device in Hemostasis during Thyroidectomy in Comparison with Ultrasonic Scalpel: A Comparative Study

Aim: Ultrasonic scalpel is one of the recent advances in surgical technology. The main limitation of their use is the cost. However, radiofrequency ablation device is a refined type of electrosurgical cautery that can be used with conventional reusable bipolar cautery forceps. This study aims to compare the efficacy of bipolar radiofrequency ablation device that can be used with conventional reusable bipolar cautery forceps for hemostasis and dissection during thyroidectomy with that of ultrasonic scalpel. Materials and Methods: Sixty patients underwent total thyroidectomy were recruited at Alshiffa General Hospital, Basrah, Iraq from March 2016 to June 2017. The participants were divided into two equal groups: in the first group thyroid dissection was done with ultrasonic scalpel, and in the second group thyroid dissection was done with bipolar radiofrequency ablation device. Outcome and complications of both procedures were analyzed statistically and compared. Results: The bipolar radiofrequency ablation device significantly reduced the mean operative time by (−15.35 min) in comparison to ultrasonic scalpel. The Bipolar Radiofrequency Ablation Device (BRFA) group reported a mean operative time of 50.13 ± 14.16 compared to 65.49 ± 7.78 in the US group with, P value = 0.001. There was no statistically significant difference in the other outcome parameters and the rate of complications reported between the two devices during this study. Conclusion: The bipolar radiofrequency ablation device that can be used with conventional reusable bipolar cautery forceps is a simple, safe, and time-saving adjunct for thyroid surgeries and equally effective as compared to costly instruments like ultrasonic scalpel. Clinical Significance: The bipolar radiofrequency device can be used in thyroid surgery to secure hemostasis, save time, and cost.

[1]  Xiaoqiao Tang,et al.  Therapeutic Effects of Bipolar Coagulation Forceps on Open Thyroid Surgery. , 2016, Revista de investigacion clinica; organo del Hospital de Enfermedades de la Nutricion.

[2]  E. Govindaraj,et al.  A Study of use of bipolar cautery in thyroidectomy for coagulating vascular pedicles instead of conventional ligation , 2015 .

[3]  Ali Bijani,et al.  Influence of thyroidectomy on postoperative serum calcium level regarding serum vitamin D status. A prospective study , 2015, Caspian journal of internal medicine.

[4]  I. Abdurrahman,et al.  Total versus bilateral subtotal thyroidectomy for benign multi-nodular goiter. , 2015, International journal of clinical and experimental medicine.

[5]  J. Ładny,et al.  The assessment of the influence of the method for obtaining hemostasis on the occurrence of postoperative complications after thyroid surgery. , 2015, Advances in clinical and experimental medicine : official organ Wroclaw Medical University.

[6]  K. Baldwin,et al.  Initial experience using a bipolar radiofrequency ablation device for hemostasis during thyroidectomy , 2013, Head & neck.

[7]  G. Spinato,et al.  Focus Harmonic Scalpel Compared to Conventional Haemostasis in Open Total Thyroidectomy: A Prospective Randomized Trial , 2011, International journal of otolaryngology.

[8]  M. Dedecjus,et al.  Comparison of lateral thermal spread using monopolar and bipolar diathermy, and the bipolar vessel sealing system ThermoStapler™ during thyroidectomy. , 2011, Polski przeglad chirurgiczny.

[9]  A. Carvalho,et al.  Hemostasis in thyroid surgery: Harmonic scalpel versus other techniques—a meta-analysis , 2010, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[10]  D. Watters,et al.  Monitoring performance in thyroidectomy: cumulative sum analysis of outcomes. , 2010, Thyroid : official journal of the American Thyroid Association.

[11]  A. Samad,et al.  Post thyroidectomy complications: the Hyderabad experience. , 2010, Journal of Ayub Medical College, Abbottabad : JAMC.

[12]  S. Agle,et al.  A Comparison of Two Methods of Hemostasis in Thyroidectomy , 2009, The American surgeon.

[13]  S. Janjanin,et al.  A prospective observational study of 363 cases operated with three different harmonic scalpels , 2009, European Archives of Oto-Rhino-Laryngology.

[14]  J. Tysome,et al.  Standard bipolar diathermy forceps vessel ligation is safe in thyroidectomy , 2009, European Archives of Oto-Rhino-Laryngology.

[15]  E. Patsouris,et al.  Comparison of Safety and Efficacy of Ultrasonic and Bipolar Thermal Energy: An Experimental Study , 2008, Surgical laparoscopy, endoscopy & percutaneous techniques.

[16]  F. Mora,et al.  New trends in head and neck surgery: a prospective evaluation of the Harmonic Scalpel. , 2008, Medical science monitor : international medical journal of experimental and clinical research.

[17]  S. Nakada,et al.  Comparison of blade temperature dynamics after activation of Harmonic Ace scalpel and the Ultracision Harmonic Scalpel LCS-K5. , 2008, Journal of endourology.

[18]  C. Huins,et al.  A new classification system for retrosternal goitre based on a systematic review of its complications and management. , 2008, International journal of surgery.

[19]  James E. Coad,et al.  Comparison of four energy-based vascular sealing and cutting instruments: A porcine model , 2008, Surgical Endoscopy.

[20]  K. Psarras,et al.  Efficacy and safety of ultrasonically activated shears in thyroid surgery , 2006, Head & neck.

[21]  Q. Duh,et al.  Use of the electrothermal vessel sealing system versus standard vessel ligation in thyroidectomy. , 2005, Asian journal of surgery.

[22]  J. Luketich,et al.  Radiofrequency ablation: identification of the ideal patient. , 2004, Clinical lung cancer.

[23]  R. Plant,et al.  Radiofrequency Treatment of Tonsillar Hypertrophy , 2002, The Laryngoscope.

[24]  J. Wedman,et al.  Treatment of Simple Snoring Using Radio Waves for Ablation of Uvula and Soft Palate: A Day‐Case Surgery Procedure , 2002, The Laryngoscope.

[25]  C. Ferrándiz,et al.  Surgical Management of Rhinophyma: Report of Eight Patients Treated with Electrosection , 2002, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[26]  M. Fried,et al.  Assessment of the morbidity and complications of total thyroidectomy. , 2002, Archives of otolaryngology--head & neck surgery.

[27]  K. Koutsoumanis,et al.  Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation. , 2008, American journal of surgery.

[28]  M. Raffaelli,et al.  [Complications in thyroid surgery]. , 1994, Chirurgia italiana.

[29]  P. Bendick,et al.  The use of thermal knives in surgery: electrosurgery, lasers, plasma scalpel. , 1978, Current problems in surgery.