Patients' Attitudes Toward Implanted Defibrillator Shocks

In addition to its beneficial effect on patient survival, the implanted cardioverter defibriliator (ICD) changes a patient's life physically, socially, and psychologically. For improved patient management, it is important to understand the quality‐of‐life changes that accompany this mode of treatment. To this end, 119 patients were surveyed retrospectively and interviewed concurrently regarding their emotional, physical, and behavioral responses to ICD shocks and to the device itself. Most (55%) correctly estimated the total number of shocks they had received within a 10% margin. They found the shocks severe, 79% assigning a score between 3 and 5 on a scale of 1–5. Common descriptions of the shock sensation were a blow to the body or a spasm causing the entire body to jump. Most patients tolerated the shocks as life saving, but 23% dreaded shocks and 5% even said they would rather be without the ICD and take their chances. After a shock, 50% of patients called their physician and 42% continued their daily routine. Thirty percent went to a hospital emergency room or called a rescue service. Sixty‐five percent had no preshock prodromes. Fifty‐four percent were interested in the programmable option of a warning signal prior to a shock, while 31 % preferred no warning. Of the 74% who were advised not to drive after implantation, 29% drove anyway. Five patients were shocked while driving with no resulting accidents. We conclude that most patients find ICD shocks moderately uncomfortable, but they tolerate them because of the lifesaving protection provided by the device.

[1]  C. Herrmann,et al.  Standardized Assessment of Psychological Well‐Being and Quality‐of‐Life in Patients with Implanted Defibrillators , 1997, Pacing and clinical electrophysiology : PACE.

[2]  B. Lüderitz,et al.  Quality of life and driving in recipients of the implantable cardioverter-defibrillator. , 1996, The American journal of cardiology.

[3]  P. Touboul,et al.  Improved appraisal of the quality of life in patients with automatic implantable cardioverter defibrillator: a psychometric study. , 1996, Psychotherapy and psychosomatics.

[4]  A B Curtis,et al.  Motor vehicle accidents in patients with an implantable cardioverter-defibrillator. , 1995, Journal of the American College of Cardiology.

[5]  J. Fernsler,et al.  Perceived quality of life before and after implantation of an internal cardioverter defibrillator. , 1995, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[6]  B. Lüderitz,et al.  Patient acceptance of implantable cardioverter defibrillator devices: changing attitudes. , 1994, American heart journal.

[7]  R. Goldberg,et al.  Psychiatric morbidity following implantation of the automatic implantable cardioverter defibrillator. , 1991, Psychosomatics.

[8]  J. Calabrese,et al.  Patient and spouse acceptance and adaptation to implantable cardioverter defibrillators. , 1990, Cleveland Clinic journal of medicine.

[9]  K. Dracup,et al.  Psychosocial adjustment of patients with ventricular dysrhythmias. , 1990, The Journal of cardiovascular nursing.

[10]  R. Myerburg,et al.  The impact of the automatic implantable cardioverter defibrillator on quality of life , 1986 .