Bioimpedance of soft tissue under compression

In this paper compression-dependent bioimpedance measurements of porcine spleen tissue are presented. Using a Cole-Cole model, nonlinear compositional changes in extracellular and intracellular makeup; related to a loss of fluid from the tissue, are identified during compression. Bioimpedance measurements were made using a custom tetrapolar probe and bioimpedance circuitry. As the tissue is increasingly compressed up to 50%, both intracellular and extracellular resistances increase while bulk membrane capacitance decreases. Increasing compression to 80% results in an increase in intracellular resistance and bulk membrane capacitance while extracellular resistance decreases. Tissues compressed incrementally to 80% show a decreased extracellular resistance of 32%, an increased intracellular resistance of 107%, and an increased bulk membrane capacitance of 64% compared to their uncompressed values. Intracellular resistance exhibits double asymptotic curves when plotted against the peak tissue pressure during compression, possibly indicating two distinct phases of mechanical change in the tissue during compression. Based on these findings, differing theories as to what is happening at a cellular level during high tissue compression are discussed, including the possibility of cell rupture and mass exudation of cellular material.

[1]  Clifford D. Ferris,et al.  Four‐Electrode Null Techniques for Impedance Measurement with High Resolution , 1968 .

[2]  D. Ingber,et al.  Cellular mechanotransduction: putting all the pieces together again , 2006, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[3]  John A Pearce,et al.  Electric field penetration depth of myocardial surface catheters and the measurement of myocardial resistivity. , 2004, Biomedical sciences instrumentation.

[4]  Sverre Grimnes,et al.  Bioimpedance and Bioelectricity Basics , 2000 .

[5]  V. Mow,et al.  Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments. , 1980, Journal of biomechanical engineering.

[6]  Brian H. Brown,et al.  Bipolar and tetrapolar transfer impedance measurements from volume conductor , 2000 .

[7]  Fernando Seoane,et al.  A novel approach for removing the hook effect artefact from Electrical Bioimpedance spectroscopy measurements , 2010 .

[8]  Eung Je Woo,et al.  Dependence of apparent resistance of four-electrode probes on insertion depth , 2000, IEEE Transactions on Biomedical Engineering.

[9]  Charles F. Wojslaw,et al.  Operational Amplifiers: The Devices and Their Applications , 1987 .

[10]  Savio L Woo,et al.  An improved method to analyze the stress relaxation of ligaments following a finite ramp time based on the quasi-linear viscoelastic theory. , 2004, Journal of biomechanical engineering.

[11]  P. Steendijk,et al.  The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivo , 1993, IEEE Transactions on Biomedical Engineering.

[12]  Fernando Seoane,et al.  Cole equation and parameter estimation from electrical bioimpedance spectroscopy measurements - A comparative study , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  James J. Ackmann,et al.  Complex bioelectric impedance measurement system for the frequency range from 5 Hz to 1 MHz , 1993, Annals of Biomedical Engineering.

[14]  R. King Exploration geophysics , 1977, Nature.

[15]  Jeffrey C Bamber,et al.  Coupling between elastic strain and interstitial fluid flow: ramifications for poroelastic imaging , 2006, Physics in medicine and biology.

[16]  K. Cole,et al.  Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics , 1941 .

[17]  R H Smallwood,et al.  Electrical bioimpedance readings increase with higher pressure applied to the measuring probe , 2005, Physiological measurement.

[18]  A. Bowdler The complete spleen : structure, function, and clinical disorders , 2002 .

[19]  Y. Fung,et al.  Biomechanics: Mechanical Properties of Living Tissues , 1981 .

[20]  Albert J. Shih,et al.  Thermal-Electric Finite Element Analysis and Experimental Validation of Bipolar Electrosurgical Cautery , 2008 .

[21]  D S Holder,et al.  A review of errors in multi-frequency EIT instrumentation , 2007, Physiological measurement.

[22]  M. P. Bolton,et al.  Sources of error in bioimpedance spectroscopy , 1998, Physiological measurement.

[23]  K. Ishibashi,et al.  Aquaporin water channels in mammals , 1997, Clinical and Experimental Nephrology.

[24]  H Scharfetter,et al.  A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy. , 1998, Physiological measurement.

[25]  J. Lotz,et al.  Pressure and Distortion Regulate Human Mesenchymal Stem Cell Gene Expression , 2009, Annals of Biomedical Engineering.

[26]  Sverre Grimnes,et al.  Sources of error in tetrapolar impedance measurements on biomaterials and other ionic conductors , 2007 .

[27]  Dispersion and Absorption in Dielectrics 1 , 2022 .

[28]  L. Geddes,et al.  Cell constant of the tetrapolar conductivity cell , 1990, Medical and Biological Engineering and Computing.

[29]  K. Foster,et al.  RF-field interactions with biological systems: Electrical properties and biophysical mechanisms , 1980, Proceedings of the IEEE.

[30]  Christopher G. Rylander,et al.  Dehydration mechanism of optical clearing in tissue. , 2006, Journal of biomedical optics.

[31]  H P Schwan,et al.  ELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS * , 1968, Annals of the New York Academy of Sciences.

[32]  Blake Hannaford,et al.  Biomechanical properties of abdominal organs in vivo and postmortem under compression loads. , 2008, Journal of biomechanical engineering.

[33]  A. Keshtkar,et al.  The effect of applied pressure on the electrical impedance of the bladder tissue using small and large probes , 2008, Journal of medical engineering & technology.

[34]  Jeffrey C Bamber,et al.  The spatio-temporal strain response of oedematous and nonoedematous tissue to sustained compression in vivo. , 2008, Ultrasound in medicine & biology.

[35]  King H. Yang,et al.  Mechanical characterization of porcine abdominal organs. , 2002, Stapp car crash journal.

[36]  Z. N. Demou Gene Expression Profiles in 3D Tumor Analogs Indicate Compressive Strain Differentially Enhances Metastatic Potential , 2010, Annals of Biomedical Engineering.