Validation of the CALUX bioassay for the screening of PCDD/Fs and dioxin-like PCBs in retail fish.

The chemical-activated luciferase expression (CALUX) assay is a reporter gene assay that detects dioxin-like compounds based on their ability to activate the aryl hydrocarbon receptor (AhR) and thus expression of the reporter gene. In this paper, the CALUX assay was examined for its application in the screening of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dioxin-like PCBs) in retail fish. The sample extracts were cleaned up on a sulfuric acid-silica gel column followed by an activated carbon column, and the AhR activity of the separated PCDD/F and dioxin-like PCB fractions was determined using the assay. The quantitative limit for 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) was 0.98 pg ml(-1) (0.19 pg assay(-1) in the standard curve, corresponding to 0.16 pg g(-1) of CALUX-based toxic equivalency (2,3,7,8-TCDD equivalents) in the tested sample. Recovery tests in which dioxins were added to fish samples resulted in acceptable recoveries (77-117%). The CALUX assay performed well in the analysis of dioxins in fish samples and a comparative study revealed a strong correlation between the CALUX assay and high-resolution gas chromatography-high-resolution mass spectrometry analysis for the determination of PCDD/Fs (r = 0.89) and dioxin-like PCBs (r = 0.91) in retail fish (n = 22). These data revealed that the CALUX assay would be a useful screening method for PCDD/Fs and dioxin-like PCBs in retail fish.

[1]  Paul D. Jones,et al.  2,3,7,8‐tetrachlorodibenzo‐p‐dioxin equivalents in tissue samples from three species in the Denver, Colorado, USA, metropolitan area , 2001, Environmental toxicology and chemistry.

[2]  P. Leonards,et al.  The calux (chemical‐activated luciferase expression) assay adapted and validated for measuring TCDD equivalents in blood plasma , 1997 .

[3]  H. Kuiper,et al.  Validation and use of the CALUX-bioassay for the determination of dioxins and PCBs in bovine milk. , 1998, Food additives and contaminants.

[4]  Safe,et al.  Toxic equivalency factors (TEFs) for PCBs, PCDDs, PCDFs for humans and wildlife. , 1998, Environmental health perspectives.

[5]  J. Giesy,et al.  Species-specific recombinant cell lines as bioassay systems for the detection of 2,3,7,8-tetrachlorodibenzo-p-dioxin-like chemicals. , 1996, Fundamental and applied toxicology : official journal of the Society of Toxicology.

[6]  T Hori,et al.  Update of daily intake of PCDDs, PCDFs, and dioxin-like PCBs from food in Japan. , 2001, Chemosphere.

[7]  V. Nelen,et al.  Comparison of CALUX-TEQ values with PCB and PCDD/F measurements in human serum of the Flanders Environmental and Health Study (FLEHS). , 2001, Toxicology letters.

[8]  P. Furst,et al.  Exposure of populations to dioxins and related compounds , 2000, Food additives and contaminants.

[9]  P. Schepens,et al.  Comparison of chemical-activated luciferase gene expression bioassay and gas chromatography for PCB determination in human serum and follicular fluid. , 2000, Environmental health perspectives.

[10]  S Sakai,et al.  Bioanalytical screening methods for dioxins and dioxin-like compounds a review of bioassay/biomarker technology. , 2001, Environment international.

[11]  K. Sasaki,et al.  Evaluation of an aqueous KOH digestion followed by hexane extraction for analysis of PCDD/Fs and dioxin-like PCBs in retailed fish , 2003, Analytical and bioanalytical chemistry.

[12]  A. Kozubík,et al.  Monitoring river sediments contaminated predominantly with polyaromatic hydrocarbons by chemical and in vitro bioassay techniques , 2001, Environmental toxicology and chemistry.