Quality Management in Blood Salvage: Implementation of Quality Assurance and Variables Affecting Product Quality

Implementation of quality management in intraoperative blood salvage with controls of product and process quality supports early recognition and repair of dysfunction if respective actions are laid down in the quality management handbook. In order to avoid insufficient quality and to improve process quality, a broad understanding of the processes and of the variables affecting quality is needed, which is based on experimental tests. For this purpose the use of fresh whole blood as test blood and of protein as parameter for determination of the plasma elimination rate is favorable over outdated banked blood and free hemoglobin. Tested this way, the process of blood collection by suction is by far not as harmful to RBCs as expected. Partially filled bowls, lower wash volumes, or a fastened filling or washing should be avoided. Plasma washout can be improved by higher wash volumes or by slower filling and washing, which avoids increased loss of RBCs. Quality management which is based on a better understanding of the procedure as well as quality controls can help to supply high-quality blood for optimal hemotherapy by blood salvage.

[1]  G. Shulman Impact of reservoir hematocrit and processing parameters on the quality of processed blood product. , 2002, AINS. Anasthesiologie, Intensivmedizin, Notfallmedizin, Schmertztherapie.

[2]  E. Hansen,et al.  Proposal for Internal Quality Management in Intra- and Postoperative Blood Salvage , 2002, Transfusion Medicine and Hemotherapy.

[3]  V. Bechmann,et al.  Intraoperative Blood Salvage in Oncologic Surgery – Answers to Current Questions , 2002, Transfusion Medicine and Hemotherapy.

[4]  P. Innerhofer,et al.  Leukocyte Activation by means of Intraoperative Blood Salvage , 2002, Transfusion Medicine and Hemotherapy.

[5]  J. Radvan,et al.  Physical Principles of Autotransfusion Systems , 2002, Transfusion Medicine and Hemotherapy.

[6]  A. Stammers,et al.  Effect of partial-filling autotransfusion bowls on the quality of reinfused product. , 2001, The journal of extra-corporeal technology.

[7]  D. Szpisjak,et al.  Debris Elimination from Partially-Filled Cell Salvage Bowls , 2001, Anesthesia and analgesia.

[8]  M. Booke,et al.  Intraoperative Autotransfusion – Influence of Technique, Speed, and Hematocrit on Quality , 2000, Transfusion Medicine and Hemotherapy.

[9]  R. Tawes,et al.  Is the "salvaged-cell syndrome" myth or reality? , 1996, American journal of surgery.

[10]  S. Gregoretti Suction‐induced hemolysis at various vacuum pressures: implications for intraoperative blood salvage , 1996, Transfusion.