Noise reduction in multi‐slice arterial spin tagging imaging

Attenuating the static signal in arterial spin tagging (ASSIST) was initially developed for 3D imaging of cerebral blood flow. To enable the simultaneous collection of cerebral blood flow and BOLD data, a multi‐slice version of ASSIST is proposed. As with the 3D version, this sequence uses multiple inversion pulses during the tagging period to suppress the static signal. To maintain background suppression in all slices, the multi‐slice sequence applies additional inversion pulses between slice acquisitions. The utility of the sequence was demonstrated by simultaneously acquiring ASSIST and BOLD data during a functional task and by collecting resting‐state ASSIST data over a large number of slices. In addition, the temporal stability of the perfusion signal was found to be 60% greater at 3 T compared to 1.5 T, which was attributed to the insensitivity of ASSIST to physiologic noise. Magn Reson Med 53:735–738, 2005. Published 2005 Wiley‐Liss, Inc.

[1]  Urs E. Ruttimann,et al.  Quantitation of Regional Cerebral Blood Flow Increases in Prefrontal Cortex during a Working Memory Task: A Steady-State Arterial Spin-Tagging Study , 1998, NeuroImage.

[2]  Egill Rostrup,et al.  Determination of relative CMRO2 from CBF and BOLD changes: Significant increase of oxygen consumption rate during visual stimulation , 1999, Magnetic resonance in medicine.

[3]  Peter van Gelderen,et al.  Fast 3D functional magnetic resonance imaging at 1.5 T with spiral acquisition , 1996, Magnetic resonance in medicine.

[4]  D. Weinberger,et al.  Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST) , 2000, Magnetic resonance in medicine.

[5]  G. Glover,et al.  Physiological noise in oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[6]  G. Crelier,et al.  Linear coupling between cerebral blood flow and oxygen consumption in activated human cortex. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[7]  J. Duyn,et al.  Pulsed arterial spin labeling: comparison of multisection baseline and functional MR imaging perfusion signal at 1.5 and 3.0 T: initial results in six subjects. , 2002, Radiology.

[8]  G. Crelier,et al.  Investigation of BOLD signal dependence on cerebral blood flow and oxygen consumption: The deoxyhemoglobin dilution model , 1999, Magnetic resonance in medicine.

[9]  M. Schnall,et al.  Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla , 2002, Magnetic resonance in medicine.

[10]  Daniel R Weinberger,et al.  Effects of indomethacin on cerebral blood flow at rest and during hypercapnia: An arterial spin tagging study in humans , 2002, Journal of magnetic resonance imaging : JMRI.

[11]  J A Frank,et al.  Measuring the effects of indomethacin on changes in cerebral oxidative metabolism and cerebral blood flow during sensorimotor activation , 2003, Magnetic resonance in medicine.

[12]  R. Buxton,et al.  Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II) , 1998 .

[13]  T. L. Davis,et al.  Calibrated functional MRI: mapping the dynamics of oxidative metabolism. , 1998, Proceedings of the National Academy of Sciences of the United States of America.