Principle and Performance of Magnetically Induced Magnetoacoustic Tomography for Tissues with Cone Shaped Transducer

The theory on the principle of the Magnetically Induced Magnetoacoustic Tomography (MI-MAT) with a cone shaped transducer in cylindrical measure configuration is proposed in this paper. The principle of MI-MAT generation and magnetoacoustic detection are theoretically deduced in formula. It is proved that the acoustic waveforms are mainly generated at the conductivity boundaries and only the configuration of the scanned layer can be reconstructed without the inner conductivity distribution using the waveforms detected around the object with the cone shaped transducer. The performance of MI-MAT, including the improved resolution at high frequency excitation and the favorable SNR dependence, provides a non- invasive means for conductivity differentiation in diagnostic imaging. The numerical simulations of the proposed theory for a cylindrical sample phantom have good agreements with the former published results and suggest the potential applications for bioimpedance imaging.

[1]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction for imaging electrical impedance of biological tissue , 2006 .

[2]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction (MAT-MI) , 2005, Physics in medicine and biology.

[3]  Qingyu Ma,et al.  Magnetoacoustic Tomography With Magnetic Induction: A Rigorous Theory , 2008, IEEE Transactions on Biomedical Engineering.

[4]  Ohin Kwon,et al.  Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm , 2002, IEEE Transactions on Biomedical Engineering.

[5]  M. Oelze,et al.  Examination of cancer in mouse models using high-frequency quantitative ultrasound. , 2006, Ultrasound in medicine & biology.

[6]  X. Gong,et al.  Study of acoustic nonlinearity parameter imaging methods in reflection mode for biological tissues. , 2004, The Journal of the Acoustical Society of America.

[7]  X. Gong,et al.  Phase-coded multi-pulse technique for ultrasonic high-order harmonic imaging of biological tissues in vitro , 2007, Physics in medicine and biology.

[8]  H. Wen,et al.  Volumetric Hall Effect Tomography — A Feasibility Study , 1999, Ultrasonic imaging.

[9]  Lihong V. Wang,et al.  Time reversal and its application to tomography with diffracting sources. , 2004, Physical review letters.

[10]  Xu Li,et al.  Imaging Electrical Impedance From Acoustic Measurements by Means of Magnetoacoustic Tomography With Magnetic Induction (MAT-MI) , 2007, IEEE Transactions on Biomedical Engineering.

[11]  Peter Basser,et al.  A theoretical model for magneto-acoustic imaging of bioelectric currents , 1994, IEEE Transactions on Biomedical Engineering.

[12]  D. Isaacson,et al.  A reconstruction algorithm for electrical impedance tomography data collected on rectangular electrode arrays , 1999, IEEE Transactions on Biomedical Engineering.

[13]  Bin He,et al.  Investigation on magnetoacoustic signal generation with magnetic induction and its application to electrical conductivity reconstruction , 2007, Physics in medicine and biology.