Unity-Power-Factor Control Based on Precise Ripple Cancellation for Fast-Response PFC Preregulator

Power-factor preregulators are commonly used in electronic equipments for minimizing the injection of current harmonics into the mains power line. However, the bandwidth of conventional preregulators are usually configured to be very small in order to achieve near-unity power factor, and this inevitably gives rise to poor dynamic response. Ripple estimation/cancellation method is used to eliminate the double-line frequency component from the sampled output voltage before it propagates into the voltage control loop, hence, the requirement of small bandwidth is not mandatory. The existing ripple estimation circuits, however, are only accurate under specific conditions, beyond which power factor will be degraded. In view of this, a new ripple estimation/cancellation network consisting of an amplitude tuner and a phase shifter based on switched-resistor circuits is proposed and verified experimentally on a 200-W boost power-factor preregulator. It is shown that the proposed ripple estimation network not only provides accurate ripple estimation over a wide range of operating conditions, it also gives a way to decouple the power factor of a preregulator from its controller bandwidth. With the aid of the proposed ripple estimation network, the desired features of fast dynamic response and unity power factor are both achieved.

[1]  J. B. Williams,et al.  Design of feedback loop in unity power factor AC to DC converter , 1989, 20th Annual IEEE Power Electronics Specialists Conference.

[2]  Anup Kumar Panda,et al.  Analysis of a single-phase AC-DC PFC boost converter with fast dynamic response , 2012, 2012 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES).

[3]  Pedro José Villegas,et al.  Dynamic limits of a power-factor preregulator , 2005, IEEE Transactions on Industrial Electronics.

[4]  Ned Mohan,et al.  Dual voltage controller based Power Factor Correction circuit for faster dynamics and zero steady state error , 2003, IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468).

[5]  Zaohong Yang,et al.  A novel technique to achieve unity power factor and fact transient response in AC-to-DC converters , 2001 .

[6]  Ying-Yu Tzou,et al.  Fast response control of a boost PFC converter , 2003, The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003..

[7]  Aleksandar Prodic,et al.  Digitally controlled low-harmonic rectifier having fast dynamic responses , 2002, APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335).

[8]  G. Garcera,et al.  A Control Circuit With Load-Current Injection for Single-Phase Power-Factor-Correction Rectifiers , 2007, IEEE Transactions on Industrial Electronics.

[9]  M.M. Hernando,et al.  Steady-State Analysis and Modeling of Power Factor Correctors With Appreciable Voltage Ripple in the Output-Voltage Feedback Loop to Achieve Fast Transient Response , 2009, IEEE Transactions on Power Electronics.

[10]  G. Narayanan,et al.  A Simple Method to Improve the Dynamic Response of Single-Phase PWM Rectifiers , 2008, IEEE Transactions on Industrial Electronics.

[11]  Paolo Tenti,et al.  Fast-response high-quality rectifier with sliding-mode control , 1993, Proceedings Eighth Annual Applied Power Electronics Conference and Exposition,.

[12]  Javier Sebastián,et al.  On the Maximum Bandwidth Attainable by Power Factor Correctors With a Standard Compensator , 2010, IEEE Transactions on Industry Applications.

[13]  Ali Davoudi,et al.  Dynamic Model Development and Variable Switching-Frequency Control for DCVM Cúk Converters in PFC Applications , 2013, IEEE Transactions on Industry Applications.

[14]  Martin Ordonez,et al.  Improving the dynamic response of power factor correctors using simple digital filters: Moving average filter comparative evaluation , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[15]  R. Ridley,et al.  Average small-signal analysis of boost power factor correction circuit , 1989 .

[16]  Siew-Chong Tan,et al.  A Unified Approach for the Derivation of Robust Control for Boost PFC Converters , 2009, IEEE Transactions on Power Electronics.

[17]  Fei Zhang,et al.  A Novel PCCM Boost PFC Converter With Fast Dynamic Response , 2011, IEEE Transactions on Industrial Electronics.

[18]  Simon Wall,et al.  Fast controller design for single-phase power-factor correction systems , 1997, IEEE Trans. Ind. Electron..

[19]  A.M. Stankovic,et al.  A fast analog controller for a unity-power factor AC/DC converter , 1994, Proceedings of 1994 IEEE Applied Power Electronics Conference and Exposition - ASPEC'94.

[20]  P. Mattavelli,et al.  METHODS TO IMPROVE DYNAMIC RESPONSE OF POWER FACTOR PREREGULATORS: AN OVERVIEW , .

[21]  Paolo Mattavelli,et al.  Power factor preregulators with improved dynamic response , 1995 .

[22]  Robert W. Erickson,et al.  Self-tuning digitally controlled low-harmonic rectifier having fast dynamic response , 2003 .