Comment and discussion on digital processing of PD pulses

Some of the more salient aspects of the digital processing technology of PD signals are examined. Most of the efforts in this field are concentrated on the application of digital analyzers for pulse height analysis, pattern recognition and identification of the physical phenomena. It is demonstrated that errors in the signal processing unit can lead to dominant mistakes in the interpretation of the test results. >

[1]  Li Jianming,et al.  Intelligent partial discharge measurement device , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[2]  R. Bartnikas,et al.  Use of a Multichannel Analyzer for Corona Pulse-Height Distribution Measurements on Cables and Other Electrical Apparatus , 1973 .

[3]  R. Bartnikas,et al.  A Simple Pulse-Height Analyzer for Partial-Discharge-Rate Measurements , 1969 .

[4]  J. Bendat,et al.  Random Data: Analysis and Measurement Procedures , 1987 .

[5]  R. Bartnikas,et al.  Digital techniques for partial discharge measurements. Discussion , 1992 .

[6]  R. Bartnikas Effect of Pulse Rise Time on the Response of Corona Detectors , 1972, IEEE Transactions on Electrical Insulation.

[7]  R. Bartnikas,et al.  On the character of different forms of partial discharge and their related terminologies , 1993 .

[8]  R. J. Brunt Physics and chemistry of partial discharge and corona. Recent advances and future challenges , 1994 .

[9]  R. Bartnikas,et al.  Spark-to-glow discharge transition due to increased surface conductivity on epoxy resin specimens , 1993 .

[10]  R. J. Brunt,et al.  Stochastic properties of partial-discharge phenomena , 1991 .

[11]  R. J. Van Brunt,et al.  Importance of unraveling memory propagation effects in interpreting data on partial discharge statistics , 1993 .

[12]  D. W. Gross,et al.  Combination of frequency spectrum analysis and partial discharge pattern recording , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[13]  R. Bartnikas,et al.  Improved Pulsed Discharge Rate Measuring Apparatus for Ionization Discharge Studies at Low Frequencies , 1966 .

[14]  A. Contin,et al.  PD analysis of rotating AC machines , 1993 .

[15]  P. von Glahn,et al.  Behavior of surface partial discharge on aluminum oxide dielectrics , 1995, Proceedings of 1995 Conference on Electrical Insulation and Dielectric Phenomena.

[16]  P. von Glahn,et al.  Partial discharged-induced aging of cast epoxies and related nonstationary behavior of the discharge statistics , 1993, Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93).

[17]  R. Bartnikas,et al.  Corona Pulse Charge Transfer at Elevated Frequencies , 1983, IEEE Transactions on Electrical Insulation.

[18]  Richard J. Van Brunt,et al.  Characterization of point‐plane corona pulses in SF6 , 1981 .

[19]  A. Gandelli,et al.  A contribution on the traceability of partial discharge measurements , 1992 .

[20]  E. Gulski Digital analysis of partial discharges , 1995 .

[21]  H. Borsi,et al.  Problems and new solutions for partial discharge measurement on high voltage cables under noisy conditions , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[22]  M. S. Mashikian,et al.  Self-learning digital filter for the field location of partial discharge in cables , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[23]  G. Stone,et al.  Fundamental Limitations in the Measurement of Corona and Partial Discharge , 1982, IEEE Transactions on Electrical Insulation.

[24]  P. von Glahn,et al.  Continuous recording and stochastic analysis of PD , 1995 .

[25]  Magdy M. A. Salama,et al.  Neural network system using the multi-layer perceptron technique for the recognition of PD pulse shapes due to cavities and electrical trees , 1995 .

[26]  R. Bartnikas Corona pulse probability density function measurements on primary distribution power cables , 1975, IEEE Transactions on Power Apparatus and Systems.

[27]  R. J. Brunt,et al.  Nonstationary behavior of partial discharge during insulation aging , 1993 .

[28]  R. Bartnikas,et al.  Effect of overvoltage on the risetime and amplitude of PD pulses , 1995 .

[29]  E. W. Cernyar,et al.  System for Measuring Conditional Amplitude, Phase, or Time Distributions of Pulsating Phenomena , 1992, Journal of research of the National Institute of Standards and Technology.

[30]  M. Hoof,et al.  Analyzing partial discharge pulse sequences-a new approach to investigate degradation phenomena , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[31]  R. Bartnikas,et al.  Discharge rate and energy loss in helium at low frequencies , 1969 .

[32]  P. von Glahn,et al.  Nonstationary behaviour of partial discharge during discharge induced ageing of dielectrics , 1995 .

[33]  P. von Glahn,et al.  Performance evaluation of a new digital partial discharge recording and analysis system , 1994 .