Pyroshock can cause failure to the objective of an aerospace structure by damaging its sensitive electronic equipment, which is responsible for performing decisive operations. A pyroshock is the high intensity shock wave that is generated when a pyrotechnic device is explosively triggered to separate, release, or activate structural subsystems of an aerospace architecture. Pyroshock measurement plays an important role in experimental simulations to understand the characteristics of pyroshock on the host structure. This paper presents a technology to measure a pyroshock wave at multiple points using laser Doppler vibrometers (LDVs). These LDVs detect the pyroshock wave generated due to an explosive-based pyrotechnical event. Field programmable gate array (FPGA) based data acquisition is used in the study to acquire pyroshock signals simultaneously from multiple channels. This paper describes the complete system design for multipoint pyroshock measurement. The firmware architecture for the implementation of multichannel data acquisition on an FPGA-based development board is also discussed. An experiment using explosive bolts was configured to test the reliability of the system. Pyroshock was generated using explosive excitation on a 22-mm-thick steel plate. Three LDVs were deployed to capture the pyroshock wave at different points. The pyroshocks captured were displayed as acceleration plots. The results showed that our system effectively captured the pyroshock wave with a peak-to-peak magnitude of 303 741 g. The contribution of this paper is a specialized architecture of firmware design programmed in FPGA for data acquisition of large amount of multichannel pyroshock data. The advantages of the developed system are the near-field, multipoint, non-contact, and remote measurement of a pyroshock wave, which is dangerous and expensive to produce in aerospace pyrotechnic tests.
[1]
Kevin James Fleming,et al.
Shock analysis using the multi point velocimeter (VISAR).
,
2003
.
[2]
Charles R. Farrar,et al.
Comparative Study of Laser Doppler Vibrometer and Capacitive Air‐coupled Transducer for Ultrasonic Propagation Imager and the New Development of an Efficient Ultrasonic Wavenumber Imaging Algorithm
,
2015
.
[3]
V. I. Bateman,et al.
Pyroshock simulation for satellite components using a tunable resonant fixture - phase 2
,
1992
.
[4]
Romualdo Ruotolo,et al.
Application of wave propagation to pyroshock analysis
,
2003
.
[5]
Theocharis Theocharides,et al.
Towards hardware stereoscopic 3D reconstruction a real-time FPGA computation of the disparity map
,
2010,
2010 Design, Automation & Test in Europe Conference & Exhibition (DATE 2010).
[6]
Roberto Ullio,et al.
Utilization of Prediction Methods in the Shock Environment Evaluation
,
2001
.
[7]
Jung-Ryul Lee,et al.
Review of pyroshock wave measurement and simulation for space systems
,
2012
.
[8]
Joao M. C. Sousa,et al.
Parallel processing method for high-speed real time digital pulse processing for gamma-ray spectroscopy
,
2010
.
[9]
Yong Jian Mao,et al.
Numerical Techniques for Predicting Pyroshock Responses of Aerospace Structures
,
2010
.
[10]
Renato Barboni,et al.
On the damping effect due to bolted junctions in space structures subjected to pyro-shock
,
2007
.