Rotor Damping Effects in Dynamic Modeling of Three-Phase Synchronous Machines Under the Stator Interturn Faults—Winding Function Approach

Condition monitoring is used for early detection of incipient faults in electrical machines. Accurate modeling and simulation of the faulty machines can help to design effective condition monitoring systems. Three-phase synchronous machines (TSMs) are widely used for electrical power generation at power plants. Winding function theory offers effective, quick, and rather simple method for modeling and simulation of faulty electrical machines; however, this method only includes real windings of the machine. Rotor damping effects have important role in dynamic performance of the TSMs. Fictitious short-circuited windings (damper windings) on the rotor direct and quadrature axes are used to model these effects in the Park's vector model. This paper offers an approach to include similar damper windings in the winding function approach for modeling TSMs with interturn fault in the stator winding. Simulation results show creation or amplification of some frequency components in the stator line current as well as the rotor field current due to the interturn fault whose frequencies are equal to the rotor speed and its integer multiples. The frequency components are also present in the circulating fault current within the shorted turns. Experimental results approve the simulation results.

[1]  Lihua Xie,et al.  Modified winding function approach to stator fault modelling of synchronous generator , 2016, 2016 12th IEEE International Conference on Control and Automation (ICCA).

[2]  V. A. Kinitsky Calculation of Internal Fault Currents in Synchronous Machines , 1965 .

[3]  A.J. Marques Cardoso,et al.  Stator winding fault diagnosis in three-phase synchronous and asynchronous motors, by the extended Park's vector approach , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[4]  Louis-A. Dessaint,et al.  A New Model of Synchronous Machine Internal Faults Based on Winding Distribution , 2006, IEEE Transactions on Industrial Electronics.

[5]  J. Nazarzadeh,et al.  A Detailed Analytical Model of a Salient-Pole Synchronous Generator Under Dynamic Eccentricity Fault , 2011, IEEE Transactions on Magnetics.

[6]  S. Nandi,et al.  Stator Interturn Fault Detection of Synchronous Machines Using Field Current and Rotor Search-Coil Voltage Signature Analysis , 2009, IEEE Transactions on Industry Applications.

[7]  Thomas G. Habetler,et al.  Transient model for induction machines with stator winding turn faults , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[8]  Z.Q. Zhu,et al.  Improved transient simulation of salient-pole synchronous generators with internal and ground faults in the stator winding , 2005, IEEE Transactions on Energy Conversion.

[9]  S. K. Panda,et al.  Hybrid Model for Wound-Rotor Synchronous Generator to Detect and Diagnose Turn-to-Turn Short-Circuit Fault in Stator Windings , 2015, IEEE Transactions on Industrial Electronics.

[10]  Jawad Faiz,et al.  Diagnosis and performance analysis of threephase permanent magnet synchronous motors with static, dynamic and mixed eccentricity , 2010 .

[11]  S E Dallas,et al.  Investigation of transient phenomena of a salient pole synchronous machine during field short-circuit using FEM , 2010, SPEEDAM 2010.

[12]  Hamid A. Toliyat,et al.  A novel method for modeling dynamic air-gap eccentricity in synchronous machines based on modified winding function theory , 1998 .

[13]  Jawad Faiz,et al.  Magnetic equivalent circuit modelling of doubly-fed induction generator with assessment of rotor inter-turn short-circuit fault indices , 2016 .

[14]  B Mahdi Ebrahimi,et al.  Feature Extraction for Short-Circuit Fault Detection in Permanent-Magnet Synchronous Motors Using Stator-Current Monitoring , 2010, IEEE Transactions on Power Electronics.

[15]  Jawad Faiz,et al.  Diagnosis methods for stator winding faults in three‐phase squirrel‐cage induction motors , 2014 .

[16]  S. E. Dallas,et al.  Interturn Stator Faults Analysis of a 200-MVA Hydrogenerator During Transient Operation Using FEM , 2011, IEEE Transactions on Energy Conversion.

[17]  Louis-A. Dessaint,et al.  Modeling and experimental validation of internal faults in salient pole synchronous machines including space harmonics , 2006, Math. Comput. Simul..

[18]  Luis Romeral,et al.  Modeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults , 2011, IEEE Transactions on Industrial Electronics.