Nonlinear joint angle control for artificially stimulated muscle

Designs of both open- and closed-loop controllers of electrically stimulated muscle that explicitly depend on a nonlinear mathematical model of muscle input-output properties are presented and evaluated. The muscle model consists of three factors: a muscle activation dynamics factor, an angle-torque relationship factor, and an angular velocity torque relationship factor. These factors are multiplied to relate output torque to input simulation and joint angle. An experimental method for the determination of the parameters of this model was designed, implemented, and evaluated. An open-loop nonlinear compensator, based upon this model, was tested in an animal model. Its performance in the control of joint angle in the presence of a known load was compared with a PID (proportional-integral-derivative) controller, and with a combination of the PID controller and the nonlinear compensator. The results are presented.<<ETX>>

[1]  A. Hill The heat of shortening and the dynamic constants of muscle , 1938 .

[2]  D. Wilkie The relation between force and velocity in human muscle , 1949, The Journal of physiology.

[3]  A. Huxley Muscle structure and theories of contraction. , 1957, Progress in biophysics and biophysical chemistry.

[4]  P. Rack,et al.  The effects of length and stimulus rate on tension in the isometric cat soleus muscle , 1969, The Journal of physiology.

[5]  G. C. Joyce,et al.  The mechanical properties of cat soleus muscle during controlled lengthening and shortening movements , 1969, The Journal of physiology.

[6]  G. C. Joyce,et al.  Isotonic lengthening and shortening movements of cat soleus muscle , 1969, The Journal of physiology.

[7]  J. Houk,et al.  An evaluation of length and force feedback to soleus muscles of decerebrate cats. , 1970, Journal of neurophysiology.

[8]  J. Houk,et al.  Improvement in linearity and regulation of stiffness that results from actions of stretch reflex. , 1976, Journal of neurophysiology.

[9]  J. van den Berg,et al.  EMG to force processing I: An electrical analogue of the Hill muscle model. , 1981, Journal of biomechanics.

[10]  J. van den Berg,et al.  EMG to force processing II: Estimation of parameters of the Hill muscle model for the human triceps surae by means of a calfergometer. , 1981, Journal of biomechanics.

[11]  J. Mortimer,et al.  The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation , 1983, IEEE Transactions on Biomedical Engineering.

[12]  N. Hogan Adaptive control of mechanical impedance by coactivation of antagonist muscles , 1984 .

[13]  P. Rack,et al.  Elastic properties of the cat soleus tendon and their functional importance. , 1984, The Journal of physiology.

[14]  Jack M. Winters,et al.  Analysis of Fundamental Human Movement Patterns Through the Use of In-Depth Antagonistic Muscle Models , 1985, IEEE Transactions on Biomedical Engineering.

[15]  L. A. Bernotas,et al.  A Discrete-Time Model of Electrcally Stimulated Muscle , 1986, IEEE Transactions on Biomedical Engineering.

[16]  G. Inbar,et al.  FNS Parameter Selection and Upper Limb Characterzation , 1986, IEEE Transactions on Biomedical Engineering.

[17]  Gideon F. Inbar,et al.  FNS Control Schemes for the Upper Limb , 1986, IEEE Transactions on Biomedical Engineering.

[18]  G. Zahalak A comparison of the mechanical behavior of the cat soleus muscle with a distribution-moment model. , 1986, Journal of biomechanical engineering.

[19]  Howard J. Chizeck,et al.  Linear Quadratic Control of a Loaded Agonist-Antagonist Muscle Pair , 1987, IEEE Transactions on Biomedical Engineering.

[20]  Moshe Solomonow,et al.  Manipulation of Muscle Force with Various Firing Rate and Recruitment Control Strategies , 1987, IEEE Transactions on Biomedical Engineering.

[21]  L. A. Bernotas,et al.  Adaptive Control of Electrically Stimulated Muscle , 1987, IEEE Transactions on Biomedical Engineering.

[22]  Lennart Ljung,et al.  System Identification: Theory for the User , 1987 .

[23]  E. B. Marsolais,et al.  Control of functional neuromuscular stimulation systems for standing and locomotion in paraplegics , 1988, Proc. IEEE.

[24]  H.J. Chizeck,et al.  Robust closed-loop control of isometric muscle force using pulsewidth modulation , 1988, IEEE Transactions on Biomedical Engineering.

[25]  J. Mortimer,et al.  A spiral nerve cuff electrode for peripheral nerve stimulation , 1988, IEEE Transactions on Biomedical Engineering.

[26]  F. Zajac Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. , 1989, Critical reviews in biomedical engineering.

[27]  W. Durfee,et al.  Methods for estimating isometric recruitment curves of electrically stimulated muscle , 1989, IEEE Transactions on Biomedical Engineering.

[28]  F.E. Zajac,et al.  Restoring unassisted natural gait to paraplegics via functional neuromuscular stimulation: a computer simulation study , 1990, IEEE Transactions on Biomedical Engineering.

[29]  H.J. Chizeck,et al.  Feedback regulation of hand grasp opening and contact force during stimulation of paralyzed muscle , 1991, IEEE Transactions on Biomedical Engineering.

[30]  J. Abbas,et al.  Feedback control of coronal plane hip angle in paraplegic subjects using functional neuromuscular stimulation , 1991, IEEE Transactions on Biomedical Engineering.