DISTq: An Iterative Analysis of Glucose Data for Low-Cost, Real-Time and Accurate Estimation of Insulin Sensitivity

Insulin sensitivity (SI) estimation has numerous uses in medical and clinical situations. However, highresolution tests that are useful for clinical diagnosis and monitoring are often too intensive, long and costly for regular use. Simpler tests that mitigate these issues are not accurate enough for many clinical diagnostic or monitoring scenarios. The gap between these tests presents an opportunity for new approaches. The quick dynamic insulin sensitivity test (DISTq) utilises the model-based DIST test protocol and a series of population estimates to eliminate the need for insulin or C-peptide assays to enable a high resolution, low-intensity, real-time evaluation of SI. The method predicts patient specific insulin responses to the DIST test protocol with enough accuracy to yield a useful clinical insulin sensitivity metric for monitoring of diabetes therapy. The DISTq method replicated the findings of the fully sampled DIST test without the use of insulin or C-peptide assays. Correlations of the resulting SI values was R=0.91. The method was also compared to the euglycaemic hyperinsulinaemic clamp (EIC) in an in-silico Monte-Carlo analysis and showed a good ability to re-evaluate SIEIC (R=0.89), compared to the fully sampled DIST (R=0.98) Population-derived parameter estimates using a-posteriori population-based functions derived from DIST test data enables the simulation of insulin profiles that are sufficiently accurate to estimate SI to a relatively high precision. Thus, costly insulin and C-peptide assays are not necessary to obtain an accurate, but inexpensive, real-time estimate of insulin sensitivity. This estimate has enough resolution for SI prediction and monitoring of response to therapy. In borderline cases, re-evaluation of stored (frozen) blood samples for insulin and C-peptide would enable greater accuracy where necessary, enabling a hierarchy of tests in an economical fashion.

[1]  C Cobelli,et al.  The kinetics of insulin in man. II. Role of the liver. , 1987, Diabetes/metabolism reviews.

[2]  N J Wareham,et al.  The effect of varying the screening interval on false positives and duration of undiagnosed disease in a screening programme for type 2 diabetes , 2000, Journal of medical screening.

[3]  J. Chan,et al.  The Reproducibility and Usefulness of the Oral Glucose Tolerance Test in Screening for Diabetes and other Cardiovascular Risk Factors , 1998, Annals of clinical biochemistry.

[4]  Claudio Cobelli,et al.  A minimal model of insulin secretion and kinetics to assess hepatic insulin extraction. , 2006, American journal of physiology. Endocrinology and metabolism.

[5]  E. Bonora,et al.  Homeostasis model assessment closely mirrors the glucose clamp technique in the assessment of insulin sensitivity: studies in subjects with various degrees of glucose tolerance and insulin sensitivity. , 2000, Diabetes care.

[6]  J. Mann,et al.  Intensive lifestyle changes are necessary to improve insulin sensitivity: a randomized controlled trial. , 2002, Diabetes care.

[7]  C Cobelli,et al.  The kinetics of insulin in man. I. General aspects. , 1987, Diabetes/metabolism reviews.

[8]  S. Haffner,et al.  Liver markers and development of the metabolic syndrome: the insulin resistance atherosclerosis study. , 2005, Diabetes.

[9]  A. Vaag,et al.  A Simple Method for Quantitation of Insulin Sensitivity and Insulin Release from an Intravenous Glucose Tolerance Test , 1992, Diabetic medicine : a journal of the British Diabetic Association.

[10]  R N Bergman,et al.  Equivalence of the insulin sensitivity index in man derived by the minimal model method and the euglycemic glucose clamp. , 1987, The Journal of clinical investigation.

[11]  Johannes D Veldhuis,et al.  Pulsatile insulin secretion dictates systemic insulin delivery by regulating hepatic insulin extraction in humans. , 2005, Diabetes.

[12]  Christopher E. Hann,et al.  Integral-based parameter identification for long-term dynamic verification of a glucose-insulin system model , 2005, Comput. Methods Programs Biomed..

[13]  R. Turner,et al.  Homeostasis model assessment: insulin resistance and β-cell function from fasting plasma glucose and insulin concentrations in man , 1985, Diabetologia.

[14]  Christopher E. Hann,et al.  Monte Carlo analysis of a new model-based method for insulin sensitivity testing , 2008, Comput. Methods Programs Biomed..

[15]  Masafumi Matsuda,et al.  beta-Cell function in subjects spanning the range from normal glucose tolerance to overt diabetes: a new analysis. , 2005, The Journal of clinical endocrinology and metabolism.

[16]  Ismail K. Youssef,et al.  Picard iteration algorithm combined with Gauss-Seidel technique for initial value problems , 2007, Appl. Math. Comput..

[17]  M. Stojanovic,et al.  Effect of insulin sensitivity on pulsatile insulin secretion. , 1999, European journal of endocrinology.

[18]  Osama Hamdy,et al.  Evaluation of insulin sensitivity in clinical practice and in research settings. , 2003, Nutrition reviews.

[19]  M. Matsuda,et al.  Insulin sensitivity indices obtained from oral glucose tolerance testing: comparison with the euglycemic insulin clamp. , 1999, Diabetes care.

[20]  R. Morris,et al.  Discrimination, adjusted correlation, and equivalence of imprecise tests: application to glucose tolerance. , 1999, The American journal of physiology.

[21]  N. Ray,et al.  Economic Consequences of Diabetes Mellitus in the U.S. in 1997 , 1998, Diabetes Care.

[22]  Andrea Mari,et al.  Methods for clinical assessment of insulin sensitivity and β-cell function , 2003 .

[23]  M. Kim,et al.  Modeling Contaminant Transport in a Three-Phase Groundwater System with the Freundlich-Type Retardation Factor , 2007, Environmental technology.

[24]  R. N. Bergman,et al.  Role of glucose and insulin resistance in development of type 2 diabetes mellitus: results of a 25-year follow-up study , 1992, The Lancet.

[25]  Estimates of in vivo insulin action in humans: comparison of the insulin clamp and the minimal model techniques. , 1985, Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme.

[26]  R. DeFronzo,et al.  Glucose clamp technique: a method for quantifying insulin secretion and resistance. , 1979, The American journal of physiology.

[27]  M. Stumvoll,et al.  Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity. , 2000, Diabetes care.

[28]  T. Lotz,et al.  High Resolution Clinical Model-Based Assessment of Insulin Sensitivity , 2007 .

[29]  P. Zimmet,et al.  Etiology of the Metabolic Syndrome: Potential Role of Insulin Resistance, Leptin Resistance, and Other Players , 1999, Annals of the New York Academy of Sciences.

[30]  Jeppe Sturis,et al.  Estimation of Insulin Secretion Rates from C-Peptide Levels: Comparison of Individual and Standard Kinetic Parameters for C-Peptide Clearance , 1992, Diabetes.

[31]  Andrea Mari,et al.  Methods for clinical assessment of insulin sensitivity and beta-cell function. , 2003, Best practice & research. Clinical endocrinology & metabolism.

[32]  A Mari,et al.  How to measure insulin sensitivity , 1998, Journal of hypertension.

[33]  G Dailey,et al.  Metabolic effects of metformin in non-insulin-dependent diabetes mellitus. , 1995, The New England journal of medicine.

[34]  Christopher E. Hann,et al.  Model-Based Insulin Sensitivity as a Sepsis Diagnostic in Critical Care , 2008, Journal of diabetes science and technology.