Hepatic lesions: improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique--evaluation of SPIO-enhanced T2-weighted MR images.

PURPOSE To evaluate the effectiveness of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique for superparamagnetic iron oxide (SPIO)-enhanced T2-weighted magnetic resonance (MR) imaging with respiratory compensation with the prospective acquisition correction (PACE) technique in the detection of hepatic lesions. MATERIALS AND METHODS The institutional human research committee approved this prospective study, and all patients provided written informed consent. Eighty-one patients (mean age, 58 years) underwent hepatic 1.5-T MR imaging. Fat-saturated T2-weighted turbo spin-echo images were acquired with the PACE technique and with and without the PROPELLER method after administration of SPIO. Images were qualitatively evaluated for image artifacts, depiction of liver edge and intrahepatic vessels, overall image quality, and presence of lesions. Three radiologists independently assessed these characteristics with a five-point confidence scale. Diagnostic performance was assessed with receiver operating characteristic (ROC) curve analysis. Quantitative analysis was conducted by measuring the liver signal-to-noise ratio (SNR) and the lesion-to-liver contrast-to-noise ratio (CNR). The Wilcoxon signed rank test and two-tailed Student t test were used, and P < .05 indicated a significant difference. RESULTS MR imaging with the PROPELLER and PACE techniques resulted in significantly improved image quality, higher sensitivity, and greater area under the ROC curve for hepatic lesion detection than did MR imaging with the PACE technique alone (P < .001). The mean liver SNR and the lesion-to-liver CNR were higher with the PROPELLER technique than without it (P < .001). CONCLUSION T2-weighted MR imaging with the PROPELLER and PACE technique and SPIO enhancement is a promising method with which to improve the detection of hepatic lesions. (c) RSNA, 2009.

[1]  S. Aoki,et al.  Evaluation of Super Paramagnetic Iron Oxide-Enhanced Diffusion-Weighted PROPELLER T2-Fast Spin Echo Magnetic Resonance Imaging: Preliminary Experience , 2006, Journal of computer assisted tomography.

[2]  P. Kim,et al.  Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences , 2011, Abdominal Imaging.

[3]  Seong Ho Park,et al.  Image quality and focal lesion detection on T2‐weighted MR imaging of the liver: Comparison of two high‐resolution free‐breathing imaging techniques with two breath‐hold imaging techniques , 2007, Journal of magnetic resonance imaging : JMRI.

[4]  R R Edelman,et al.  Liver masses: replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging. , 1996, Radiology.

[5]  B. Hamm,et al.  Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction. , 2005, Magnetic resonance imaging.

[6]  A. Shimakawa,et al.  Motion suppression in MR imaging of the liver: comparison of respiratory-triggered and nontriggered fast spin-echo sequences. , 1997, AJR. American journal of roentgenology.

[7]  D. Mitchell,et al.  Abdominal MR imaging: evaluation of a fast spin-echo sequence. , 1994, Radiology.

[8]  E M Haacke,et al.  Improving MR image quality in the presence of motion by using rephasing gradients. , 1987, AJR. American journal of roentgenology.

[9]  Bernd Hamm,et al.  Magnetic resonance imaging of the upper abdomen using a free‐breathing T2‐weighted turbo spin echo sequence with navigator triggered prospective acquisition correction , 2005, Journal of magnetic resonance imaging : JMRI.

[10]  J. Reinig Breath-hold fast spin-echo MR imaging of the liver: a technique for high-quality T2-weighted images. , 1995, Radiology.

[11]  R. S. Hinks,et al.  Gradient moment nulling in fast spin echo , 1994, Magnetic resonance in medicine.

[12]  Kaori Togashi,et al.  Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen , 2008, Journal of magnetic resonance imaging : JMRI.

[13]  Andrew C Larson,et al.  Multishot Diffusion-Weighted PROPELLER Magnetic Resonance Imaging of the Abdomen , 2006, Investigative radiology.

[14]  T. Ichikawa,et al.  Fast magnetic resonance imaging of liver. , 1999, European journal of radiology.

[15]  B. V. Van Beers,et al.  Detection and segmental location of malignant hepatic tumors: comparison of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging. , 1997, AJR. American journal of roentgenology.

[16]  E M Haacke,et al.  Reducing motion artifacts in two-dimensional Fourier transform imaging. , 1986, Magnetic resonance imaging.

[17]  J G Pipe,et al.  PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motion , 2001, Journal of magnetic resonance imaging : JMRI.

[18]  E. Jeong,et al.  Comparison of multishot turbo spin echo and HASTE sequences for T2‐weighted MRI of liver lesions , 1998, Journal of magnetic resonance imaging : JMRI.

[19]  H. Schild,et al.  Improving the detectability of focal liver lesions on T2‐weighted MR images: Ultrafast breath‐hold or respiratory‐triggered thin‐section MRI? , 2001, Journal of magnetic resonance imaging : JMRI.

[20]  M. L. Wood,et al.  MR image artifacts from periodic motion. , 1985, Medical physics.

[21]  J. Pipe,et al.  Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging. , 2002, Radiology.

[22]  L. Braitman,et al.  Magnetization transfer of hepatic lesions: evaluation of a novel contrast technique in the abdomen. , 1992, Radiology.

[23]  D. Khayat,et al.  Liver metastases: safety and efficacy of detection with superparamagnetic iron oxide in MR imaging. , 1994, Radiology.

[24]  J. Watarai,et al.  Tumor‐liver contrast and subjective tumor conspicuity of respiratory‐triggered T2‐weighted fast spin‐echo sequence compared with T2*‐weighted gradient recalled‐echo sequence for ferucarbotran‐enhanced magnetic resonance imaging of hepatic malignant tumors , 2008, Journal of magnetic resonance imaging : JMRI.

[25]  H. Hricak,et al.  Magnetic resonance imaging with respiratory gating: techniques and advantages. , 1984, AJR. American journal of roentgenology.

[26]  Kaori Togashi,et al.  MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique. , 2008, AJR. American journal of roentgenology.

[27]  M. McConnell,et al.  Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. , 1997, AJR. American journal of roentgenology.

[28]  Bong Soo Kim,et al.  Comparison of three free-breathing T2-weighted MRI sequences in the evaluation of focal liver lesions. , 2008, AJR. American journal of roentgenology.

[29]  Janice Ward,et al.  Colorectal hepatic metastases: detection with SPIO-enhanced breath-hold MR imaging--comparison of optimized sequences. , 2003, Radiology.

[30]  C. Tempany,et al.  Superparamagnetic Iron Oxide Hepatic MR Imaging: Efficacy and Safety Using Conventional and Fast Spin‐Echo Pulse Sequences , 1995, Journal of magnetic resonance imaging : JMRI.

[31]  James G Pipe,et al.  Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. , 2003, AJNR. American journal of neuroradiology.

[32]  S. Schoenberg,et al.  High‐resolution MR‐imaging of the liver with T2‐weighted sequences using integrated parallel imaging: Comparison of prospective motion correction and respiratory triggering , 2004, Journal of magnetic resonance imaging : JMRI.

[33]  R. Murakami,et al.  Hepatocellular carcinoma in cirrhotic livers: detection with unenhanced and iron oxide-enhanced MR imaging. , 1995, Radiology.

[34]  T. Winter,et al.  MR imaging with i.v. superparamagnetic iron oxide: efficacy in the detection of focal hepatic lesions. , 1993, AJR. American journal of roentgenology.

[35]  T. Murakami,et al.  Focal hepatic lesion detection: comparison of four fat-suppressed T2-weighted MR imaging pulse sequences. , 1999, Radiology.

[36]  A. G. Collins,et al.  Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. , 1985, Journal of computer assisted tomography.

[37]  Val M. Runge,et al.  Brain Magnetic Resonance Imaging at 3 Tesla Using BLADE Compared With Standard Rectilinear Data Sampling , 2006, Investigative radiology.

[38]  Weifang Yang,et al.  Using an MRI distortion transfer function to characterize the ghosts in motion-corrupted images , 2000, IEEE Transactions on Medical Imaging.

[39]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.