Optical readout of superheated emulsions

Abstract Prompted by earlier studies on position-sensitive measurements of bubble distributions in three-dimensional (3D) dosimetry applications, optical read-out systems for superheated emulsions have been investigated and developed for bubble imaging and counting. The approach relies on light scattering by the bubbles in the emulsions either to determine attenuation profiles for optical tomography or to determine the integral number of bubbles for personal dosimetry applications. Optical tomography is clearly suitable for the development of bench-top systems for the analysis of the 3D dose distributions from brachytherapy sources. However, the approach requires optimization in terms of scanning and image reconstruction parameters. This study also suggests that compact devices based on scattered light measurements may be a viable option for personal dosimetry applications. Once fully developed, they should permit a real-time read-out of bubble vaporizations, independent of radiation dose rate and vibration or noise levels.

[1]  Francesco D'Errico,et al.  Radiation dosimetry and spectrometry with superheated emulsions , 2001 .

[2]  S. Holland,et al.  A position-sensitive neutron spectrometer/dosimeter based on pressurized superheated drop (bubble) detectors , 2002 .

[3]  J. Gore,et al.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner. , 1996, Physics in medicine and biology.

[4]  V. Schmithorst,et al.  Fast high‐resolution 3D segmented echo planar imaging for dose mapping using a superheated emulsion chamber , 2003, Magnetic resonance in medicine.

[5]  David Flynn,et al.  An acoustical bubble counter for superheated drop detectors. , 2006, Radiation protection dosimetry.

[6]  J. Gore,et al.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel. , 1996, Physics in medicine and biology.

[7]  M. Oldham 3D dosimetry by optical-CT scanning. , 2006, Journal of physics. Conference series.

[8]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[9]  S K Holland,et al.  A position-sensitive superheated emulsion chamber for three-dimensional photon dosimetry. , 1998, Physics in medicine and biology.

[10]  V. Schmithorst,et al.  System for automated magnetic resonance imaging of a superheated emulsion chamber for brachytherapy dosimetry , 2002 .

[11]  S. Roy,et al.  Instrument to detect vapor nucleation of superheated drops , 1983 .

[12]  S. Holland,et al.  Magnetic resonance imaging of microbubbles in a superheated emulsion chamber for brachytherapy dosimetry. , 1998, Medical physics.