Influence of Cooling Water Flow Rate on Start and Heat Transfer Performance of Pulsating Heat Pipe at Different Inclination Angles

Pulsating heat pipe (PHP) is an efficient heat transfer technology applied in the fields of heat dissipation and energy utilization. There are many factors affecting the heat transfer of PHP, including working fluid, filling ratio, inclination angle, etc. The cooling capacity of the cooling water system at the condensing section to the working fluid is also an important factor affecting the starting and operating of PHP. The research on PHP at different cooling water flow rates is of great significance for enhancing the operating performance. An experimental investigation of starting and running performance is carried out on a closed loop PHP with ultrapure water under different inclination angles of 90°, 60° and 30°. The starting and heat transfer performance of PHP with a filling ratio of 50% is obtained by adjusting the heat input in the range of 30–210 W at different cooling water flow rates of 6.7 g/s, 9.7 g/s and 13.9 g/s. The temperature and heat transfer resistance are used for analyzing the heat transfer performance. The results show that the starting mode, initial pulsating temperature and different heat transfer effects are brought about by different cooling water flow rates. It is observed that the cooling water flow rate has no obvious influence on the starting mode of PHP and that the starting mode of PHP is temperature progressive, starting with the increase in cooling water flow rates at a heating input of about 30 W. The influence of cooling water flow rates on the heat transfer performance of PHP is affected in a different way by inclination angles. The heat transfer performance of PHP with an inclination angle of 90° is similar at 6.7 g/s, 9.7 g/s and 13.9 g/s but, under the condition of 60° and 30°, the heat transfer resistance drops within a certain range effectively with an increasing cooling water flow rate from 6.7 g/s to 9.7 g/s and the heat transfer performance does not change significantly with the cooling water flow rate increasing to 13.9 g/s. Thus, there is an optimal value for the cooling water flow rate during the operating of PHP. The inclination angle also has an important effect on the temperature pulsating, and the temperature of PHP affected by gravity is stable with an inclination angle of 90°. However, the reduced influence of gravity on the backflow of the working fluid drops when the inclination angle decreases from 90° to 30°, and the wall temperature increases due to local overheating when the high heat input occurs.

[1]  Qianqian Wang,et al.  Starting and running performance of a pulsating heat pipe with micro encapsulated phase change material , 2022, Applied Thermal Engineering.

[2]  S. Jung,et al.  Effect of active and passive cooling on the thermo-hydrodynamic behaviors of the closed-loop pulsating heat pipes , 2020 .

[3]  R. Das,et al.  Experimental Analysis of a Novel Solar Pond Driven Thermoelectric Energy System , 2020, Journal of Energy Resources Technology.

[4]  R. Das,et al.  Waste heat recovery from a biomass heat engine for thermoelectric power generation using two-phase thermosyphons , 2020 .

[5]  M. Alhuyi Nazari,et al.  Experimental investigation of paraffin nano-encapsulated phase change material on heat transfer enhancement of pulsating heat pipe , 2019, Journal of Thermal Analysis and Calorimetry.

[6]  Honghai Yang,et al.  Experimental study on a pulsating heat pipe heat exchanger for energy saving in air-conditioning system in summer , 2019, Energy and Buildings.

[7]  W. Cai,et al.  An experimental investigation of thermal performance of pulsating heat pipe with alcohols and surfactant solutions , 2018 .

[8]  Zhang Xiaohui,et al.  Experimental investigation of a solar collector integrated with a pulsating heat pipe and a compound parabolic concentrator , 2017 .

[9]  Li Jia,et al.  Investigation on thermal design of a rack with the pulsating heat pipe for cooling CPUs , 2017 .

[10]  Emad Sadeghinezhad,et al.  Effect of nitrogen-doped graphene nanofluid on the thermal performance of the grooved copper heat pipe , 2016 .

[11]  Cui Xiaoyu,et al.  A study of the heat transfer performance of a pulsating heat pipe with ethanol-based mixtures , 2016 .

[12]  R. Naik,et al.  Theoretical Studies on the Application of Pulsating Heat Pipe in Vapour Compression Refrigeration System , 2014 .

[13]  S. Rittidech,et al.  Internal flow patterns on heat transfer characteristics of a closed-loop oscillating heat-pipe with check valves using ethanol and a silver nano-ethanol mixture , 2010 .

[14]  Li Yan,et al.  Experimental research on heat transfer of pulsating heat pipe , 2008 .

[15]  Pradit Terdtoon,et al.  Thermal performance of horizontal closed-loop oscillating heat pipes , 2008 .

[16]  Yuwen Zhang,et al.  Advances and Unsolved Issues in Pulsating Heat Pipes , 2008 .

[17]  Jinliang Xu,et al.  Start-up and steady thermal oscillation of a pulsating heat pipe , 2005 .

[18]  Manfred Groll,et al.  Understanding operational regimes of closed loop pulsating heat pipes: an experimental study , 2003 .

[19]  Shi Mingheng,et al.  Experimental Study on Start-up Performance of Closed Loop Pulsating Heat Pipe , 2011 .