Parameter identification and self-commissioning of AC permanent magnet machines - A review

Parameter identification of permanent magnet synchronous machines is a topic of utmost interest these days. The growing effort and investment in this field of research is largely due to the ever-expanding market share of these machines. The high-performance and efficient control of the drive depends on the accuracy with which the information about the machine connected to its terminals is available. The available identification methods are surveyed here and they are classified into offline and online strategies. Self-commissioning, in principle, is a subset of offline methods, yet it is treated separately for its importance in modern adjustable speed drives that tend to minimize the user intervention. Fully exploiting the power electronic converter and the computational power on-board a modern drive, the self-commissioning feature can be embedded in the start-up routine of the drive to estimate the parameters of the machine at hand. This paper presents a review of the parameter identification techniques and schemes investigated over the past few decades.

[1]  J.-P. Louis,et al.  Parameters estimation of permanent magnet synchronous machine without adding extra-signal as input excitation , 2004, 2004 IEEE International Symposium on Industrial Electronics.

[2]  Yonghua Cheng,et al.  Identification of PM synchronous machines in the frequency domain by broadband excitation , 2008, 2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion.

[3]  P. Pillay,et al.  Literature survey of permanent magnet AC motors and drives , 1989, Conference Record of the IEEE Industry Applications Society Annual Meeting,.

[4]  Radu Iustin Bojoi,et al.  Self-commissioning of interior permanent magnet synchronous motor drives with high-frequency current injection , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[5]  S. Hiti,et al.  Identification of machine parameters of a synchronous motor , 2003, IEEE Transactions on Industry Applications.

[6]  S. Ichikawa,et al.  Sensorless control for all types of synchronous motors using an on-line parameter identification , 2004, 30th Annual Conference of IEEE Industrial Electronics Society, 2004. IECON 2004.

[7]  Wootaik Lee,et al.  Experimental Estimation of Inductance for Interior Permanent Magnet Synchronous Machine Considering Temperature Distribution , 2013, IEEE Transactions on Magnetics.

[8]  Ed.C. Bortoni,et al.  A standstill frequency response method for large salient pole synchronous machines , 2004, IEEE Transactions on Energy Conversion.

[9]  Jeremi Regnier,et al.  On-line parameter estimation of PMSM in open loop and closed loop , 2009, 2009 IEEE International Conference on Industrial Technology.

[10]  Silverio Bolognani,et al.  Commissioning of Electromechanical Conversion Models for High Dynamic PMSM Drives , 2010, IEEE Transactions on Industrial Electronics.

[11]  M. Trlep,et al.  Evaluation of saturation and cross-magnetization effects in interior permanent magnet synchronous motor , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[12]  Shafiq Ahmed Odhano Self-Commissioning of AC Motor Drives , 2014 .

[13]  Gianmario Pellegrino,et al.  Experimental Identification of the Magnetic Model of Synchronous Machines , 2013, IEEE Transactions on Industry Applications.

[14]  Tine L. Vandoorn,et al.  Generation of Multisinusoidal Test Signals for the Identification of Synchronous-Machine Parameters by Using a Voltage-Source Inverter , 2010, IEEE Transactions on Industrial Electronics.

[15]  Bojan Štumberger,et al.  Determination of parameters of synchronous motor with permanent magnets from measurement of load conditions , 1997 .

[16]  K. Matsuse,et al.  Prediction of starting performance of PM motor by DC decay testing method , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[17]  David Uzel,et al.  Optimal control and identification of model parameters of traction interior permanent magnet synchronous motor drive , 2011, IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society.

[18]  M. A. Rahman,et al.  History of interior permanent magnet motors [History] , 2013, IEEE Industry Applications Magazine.

[19]  Seung-Ki Sul,et al.  Maximum Torque per Ampere (MTPA) Control of an IPM Machine Based on Signal Injection Considering Inductance Saturation , 2013, IEEE Transactions on Power Electronics.

[20]  Tomonobu Senjyu,et al.  Parameter identification for interior permanent-magnet synchronous motor , 2007, 2007 International Conference on Electrical Machines and Systems (ICEMS).

[21]  Torben Ole Andersen,et al.  Self-commissioning of permanent magnet synchronous machine drives using hybrid approach , 2014 .

[22]  B. Szabados,et al.  Dynamic motor parameter identification for high speed flux weakening operation of brushless permanent magnet synchronous machines , 1999 .

[23]  Alberto Tenconi,et al.  Identification of the Magnetic Model of Permanent-Magnet Synchronous Machines Using DC-Biased Low-Frequency AC Signal Injection , 2015, IEEE Transactions on Industry Applications.

[24]  J. A. Walker,et al.  Simulation and Analysis of Magnetisation Characteristics of Interior Permanent Magnet Motors , 2005 .

[25]  Kan Liu,et al.  Position Offset-Based Parameter Estimation for Permanent Magnet Synchronous Machines Under Variable Speed Control , 2015, IEEE Transactions on Power Electronics.

[26]  Rastislav Pavlanin,et al.  VHFIM sensorless control of PMSM , 2010, 2010 IEEE International Symposium on Industrial Electronics.

[27]  M. Zigliotto,et al.  Estimation of the direct-axis inductance in PM synchronous motor drives at standstill , 2013, 2013 IEEE International Conference on Industrial Technology (ICIT).

[28]  Gorazd Štumberger,et al.  Magnetically nonlinear dynamic model of synchronous motor with permanent magnets , 2007 .

[29]  G. Friedrich,et al.  A cross saturation model for interior permanent magnet synchronous machine. Application to a starter-generator , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[30]  Ignazio Marongiu,et al.  Discrete-Time Parameter Identification of a Surface-Mounted Permanent Magnet Synchronous Machine , 2013, IEEE Transactions on Industrial Electronics.

[31]  Ching-Tsai Pan,et al.  Estimation of parameters of interior permanent magnet synchronous motors , 2002 .

[32]  Hong Li,et al.  The implementation of parameter identification in the control of permanent magnet synchronous motor , 2011, 2011 2nd International Conference on Artificial Intelligence, Management Science and Electronic Commerce (AIMSEC).

[33]  Wei Fan,et al.  Adaptive parameter identification based on dead-time compensation for Permanent Magnet Synchronous Machines for the 2011 11th international conference on control, automation and systems (ICCAS 2011) , 2011, 2011 11th International Conference on Control, Automation and Systems.

[34]  Wang Weihua,et al.  Research on predictive control for PMSM based on online parameter identification , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.

[35]  Ali Keyhani,et al.  Estimation of permanent magnet motor parameters , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[36]  N. Bianchi,et al.  Magnetic models of saturated interior permanent magnet motors based on finite element analysis , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[37]  M.F. Rahman,et al.  A Comparative Analysis of Two Test Methods of Measuring$d$- and$q$-Axes Inductances of Interior Permanent-Magnet Machine , 2006, IEEE Transactions on Magnetics.

[38]  Juan A. Tapia,et al.  Design Principles of Permanent Magnet Synchronous Machines for Parallel Hybrid or Traction Applications , 2013, IEEE Transactions on Industrial Electronics.

[39]  Thomas M. Jahns,et al.  Interior Permanent-Magnet Synchronous Motors for Adjustable-Speed Drives , 1986, IEEE Transactions on Industry Applications.

[40]  Iqbal Husain,et al.  Online Parameter Estimation and Adaptive Control of Permanent-Magnet Synchronous Machines , 2010, IEEE Transactions on Industrial Electronics.

[41]  K. Krischan,et al.  A self-commissioning method for permanent magnet dc-motor drives , 2007, 2007 European Conference on Power Electronics and Applications.

[42]  G. Pellegrino,et al.  Direct Flux Field-Oriented Control of IPM Drives With Variable DC Link in the Field-Weakening Region , 2009, IEEE Transactions on Industry Applications.

[43]  Silverio Bolognani,et al.  On-line parameter commissioning in sensorless PMSM drives , 1997, ISIE '97 Proceeding of the IEEE International Symposium on Industrial Electronics.

[44]  H.A. Toliyat,et al.  Online Parameter Estimation of Permanent-Magnet Assisted Synchronous Reluctance Motor , 2007, IEEE Transactions on Industry Applications.

[45]  G. Pellegrino,et al.  Unified Direct-Flux Vector Control for AC Motor Drives , 2011, IEEE Transactions on Industry Applications.

[46]  A. Brune,et al.  Modelling and FE parameter identification of permanent magnet synchronous machines in consideration of spatial harmonics , 2010, The XIX International Conference on Electrical Machines - ICEM 2010.

[47]  J. Soulard,et al.  Inductance Calculations of Permanent-Magnet Synchronous Machines Including Flux Change and Self- and Cross-Saturations , 2008, IEEE Transactions on Magnetics.

[48]  Thomas M. Jahns,et al.  Magnetic Model Self-Identification for PM Synchronous Machine Drives , 2015, IEEE Transactions on Industry Applications.

[49]  Jin Xu,et al.  Self-Commissioning of Permanent Magnet Synchronous Machine Drives at Standstill Considering Inverter Nonlinearities , 2014, IEEE Transactions on Power Electronics.

[50]  Y. Takeda,et al.  Mechanical Sensorless Drives of IPMSM With Online Parameter Identification , 2005, IEEE Transactions on Industry Applications.

[51]  Andrea Cavagnino,et al.  Axial flux interior PM synchronous motor: parameters identification and steady-state performance measurements , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[52]  Jing Zhang,et al.  Influence of Nonideal Voltage Measurement on Parameter Estimation in Permanent-Magnet Synchronous Machines , 2012, IEEE Transactions on Industrial Electronics.

[53]  Tomonobu Senjyu,et al.  Self-Commissioning for Surface-Mounted Permanent Magnet Synchronous Motors , 2001 .

[54]  Yasser Gaber,et al.  Sensorless control drive of permanent magnet motor based on a simple on-line parameter identification scheme , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[55]  D. Howe,et al.  Calculation of d- and q-axis inductances of PM brushless ac machines accounting for skew , 2005, IEEE Transactions on Magnetics.

[56]  Jacek F. Gieras,et al.  Calculation of synchronous reactances of small permanent-magnet alternating-current motors: comparison of analytical approach and finite element method with measurements , 1998 .

[57]  Xi Xiao,et al.  Dynamic Permanent Magnet Flux Estimation of Permanent Magnet Synchronous Machines , 2010, IEEE Transactions on Applied Superconductivity.

[58]  Olivier Bachelier,et al.  A simplified least squares identification of permanent magnet synchronous motor parameters at standstill , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[59]  Nejila Parspour,et al.  Torque Ripple Minimization Using Online Estimation of the Stator Resistances With Consideration of Magnetic Saturation , 2014, IEEE Transactions on Industrial Electronics.

[60]  E. G. Strangas,et al.  A simplified characterization method including saturation effects for permanent magnet Machines , 2012, 2012 XXth International Conference on Electrical Machines.

[61]  A. Tessarolo Accurate Computation of Multiphase Synchronous Machine Inductances Based on Winding Function Theory , 2012, IEEE Transactions on Energy Conversion.

[62]  C. Mademlis,et al.  On Considering Magnetic Saturation with Maximum Torque to Current Control in Interior Permanent Magnet Synchronous Motor Drives , 2001, IEEE Power Engineering Review.

[63]  Zion Tsz Ho Tse,et al.  Investigating safety issues related to Electric Vehicle wireless charging technology , 2014, 2014 IEEE Transportation Electrification Conference and Expo (ITEC).

[64]  Jeong-Jong Lee,et al.  An improved AC standstill method for testing inductances of interior PM synchronous motor considering cross-magnetizing effect , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[65]  M.A. Jabbar,et al.  Determination of Parameters for Internal Permanent Magnet Synchronous Motors , 2005, IEEE International Conference on Electric Machines and Drives, 2005..

[66]  Hans-Peter Nee,et al.  Determination of d and q reactances of permanent-magnet synchronous motors without measurements of the rotor position , 2000 .

[67]  Y Inoue,et al.  Performance Improvement of Sensorless IPMSM Drives in a Low-Speed Region Using Online Parameter Identification , 2011, IEEE Transactions on Industry Applications.

[68]  R. Krishnan,et al.  Fast estimation and compensation of rotor flux linkage in permanent magnet synchronous machines , 1999, ISIE '99. Proceedings of the IEEE International Symposium on Industrial Electronics (Cat. No.99TH8465).

[69]  Yuting Gao,et al.  Review of off-line synchronous inductance measurement method for permanent magnet synchronous machines , 2014, 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific).

[70]  Shinji Doki,et al.  Sensorless control of permanent-magnet synchronous motors using online parameter identification based on system identification theory , 2006, IEEE Transactions on Industrial Electronics.

[71]  K. J. Binns,et al.  Estimation of parameters and performance of rare-earth permanent-magnet motors avoiding measurement of load angle , 1991 .