Leak Size, Detectability and Test Conditions in Pressurized Pipe Systems
暂无分享,去创建一个
Bryan W. Karney | Silvia Meniconi | Bruno Brunone | Christian Massari | Marco Ferrante | M. Ferrante | B. Karney | C. Massari | B. Brunone | S. Meniconi
[1] Silvia Meniconi,et al. Leak-edge detection , 2009 .
[2] Yeou-Koung Tung,et al. Essential system response information for transient-based leak detection methods , 2010 .
[3] M. Larson,et al. Leak Detection through Hydraulic Transient Analysis , 1992 .
[4] Rolf Isermann. Leak detection of pipelines , 2011 .
[5] James A. Liggett,et al. LEAKS IN PIPE NETWORKS , 1992 .
[6] Silvia Meniconi,et al. Water-hammer pressure waves interaction at cross-section changes in series in viscoelastic pipes , 2012 .
[7] Marco Ferrante,et al. Experimental Investigation of the Effects of Pipe Material on the Leak Head-Discharge Relationship , 2012 .
[8] Silvia Meniconi,et al. Portable pressure wave‐maker for leak detection and pipe system characterization , 2008 .
[9] Angus R. Simpson,et al. Leak Detection and Calibration Using Transients and Genetic Algorithms , 2000 .
[10] Pratyusha Bhimavarapu. Leak detection and calibration using transients and genetic algorithms , 2011 .
[11] Lennart Jönsson,et al. Leak detection in single pipelines using hydraulic transients – experimental and field studies, , 2006 .
[12] J. E. van Zyl,et al. An experimental investigation into the pressure - leakage relationship of some failed water pipes , 2007 .
[13] Angus R. Simpson,et al. LEAK DETECTION IN PIPELINES USING THE DAMPING OF FLUID TRANSIENTS , 2002 .
[14] J. Liggett,et al. Inverse Transient Analysis in Pipe Networks , 1994 .
[15] Zoran Kapelan,et al. Incorporation of prior information on parameters in inverse transient analysis for leak detection and roughness calibration , 2004 .
[16] Angus R. Simpson,et al. Experimental verification of the frequency response method for pipeline leak detection , 2006 .
[17] Wieslaw J. Staszewski,et al. Comparative study of instantaneous frequency based methods for leak detection in pipeline networks , 2012 .
[18] Helena M. Ramos,et al. Case Studies of Leak Detection and Location in Water Pipe Systems by Inverse Transient Analysis , 2010 .
[19] Bryan W. Karney,et al. A selective literature review of transient-based leak detection methods , 2009 .
[20] Bruno Brunone,et al. Transient Test-Based Technique for Leak Detection in Outfall Pipes , 1999 .
[21] M. Ferrante,et al. Transient hydrodynamics of in-line valves in viscoelastic pressurized pipes: long-period analysis , 2012 .
[22] Zoran S. Kapelan,et al. A hybrid inverse transient model for leakage detection and roughness calibration in pipe networks , 2003 .
[23] Kinshuk Dudeja,et al. Frequency Domain Analysis for Detecting Pipeline Leaks , 2015 .
[24] Bryan W. Karney,et al. Energy and Costs of Leaky Pipes: Toward Comprehensive Picture , 2002 .
[25] Angus R. Simpson,et al. Single-Event Leak Detection in Pipeline Using First Three Resonant Responses , 2013 .
[26] Silvia Meniconi,et al. Wavelets for the Analysis of Transient Pressure Signals for Leak Detection , 2007 .
[27] Helena M. Ramos,et al. Pressure Control for Leakage Minimisation in Water Distribution Systems Management , 2006 .
[28] Hong-Ye Gao,et al. Wavelet analysis [for signal processing] , 1996 .
[29] Silvia Meniconi,et al. Is the leak head–discharge relationship in polyethylene pipes a bijective function? , 2012 .
[30] Witness Mpesha,et al. Leak detection in pipes by frequency response method using a step excitation , 2001 .
[31] Silvia Meniconi,et al. Numerical and experimental investigation of leaks in viscoelastic pressurized pipe flow , 2012 .
[32] M F Lambert,et al. Leak location in single pipelines using transient reflections , 2007 .
[33] M. Ferrante,et al. Detecting leaks in pressurised pipes by means of transients , 2001 .
[34] Silvia Meniconi,et al. Leak detection in branched pipe systems coupling wavelet analysis and a Lagrangian model. , 2009 .
[35] Silvia Meniconi,et al. Diagnosis of Pipe Systems by means of a Stochastic Successive Linear Estimator , 2013, Water Resources Management.
[36] Chyr Pyng Liou,et al. Pipeline Leak Detection by Impulse Response Extraction , 1998 .
[37] Luisa Fernanda Ribeiro Reis,et al. Leak detection by inverse transient analysis in an experimental PVC pipe system , 2011 .
[38] J. C. P. Liou,et al. Leak Detection—Transient Flow Simulation Approaches , 1995 .
[39] Sandra Lucia da Cruz,et al. Pressure wave behaviour and leak detection in pipelines , 1996 .
[40] Bruno Brunone,et al. Pipe system diagnosis and leak detection by unsteady-state tests. 1. Harmonic analysis , 2003 .
[41] M. Chaudhry,et al. Leak detection in pipes by frequency response method using a step excitation , 2001 .
[42] Ali Haghighi,et al. Leak detection in pipelines by inverse backward transient analysis , 2009 .
[43] J. Liggett,et al. Experimental Observation and Analysis of Inverse Transients for Pipeline Leak Detection , 2007 .
[44] B. Karney,et al. Wavelet processing of transient signals for pipeline leak location and quantification , 2016 .
[45] Sanghyun Kim. Extensive Development of Leak Detection Algorithm by Impulse Response Method , 2005 .
[46] Thomas M. Walski,et al. Modeling leakage reduction through pressure control , 2006 .
[47] Angus R. Simpson,et al. Leak location in pipelines using the impulse response function , 2007 .
[48] Zoran Kapelan,et al. A review of methods for leakage management in pipe networks , 2010 .
[49] Silvia Meniconi,et al. Experimental Evidence of Hysteresis in the Head-Discharge Relationship for a Leak in a Polyethylene Pipe , 2011 .
[50] Pedro J. Lee,et al. Leak detection in complex series pipelines by using the system frequency response method , 2011 .