Multiple-electrode radiofrequency ablations using Octopus® electrodes in an in vivo porcine liver model.

OBJECTIVES The objective of this study was to determine the in vivo efficacy of radiofrequency ablation (RFA) in porcine liver using Octopus® electrodes for creating a large coagulation compared with RFA using clustered electrodes. METHODS A total of 39 coagulations were created using a 200-W generator and clustered electrodes or Octopus electrodes during laparotomy in 19 pigs. Radiofrequency was applied to the livers using four protocols: (1) Group A-1, monopolar mode using a clustered electrode (n=11); (2) Group A-2, monopolar mode using an Octopus electrode (n=11); (3) Group B-1, consecutive monopolar mode using three, clustered electrodes (n=8); and (4) Group B-2, switching monopolar mode using two Octopus electrodes (n=9). The energy efficiency, shape, diameters (D) and volume (V) of the coagulation volume were compared in each of the two groups. RESULTS The mean maximum D and V of the coagulations in Group A-2 (4.7 cm and 33.1 cm(3), respectively) were significantly larger than those in Group A-1 (4.1 cm and 20.3 cm(3), respectively) (p<0.05). Furthermore, the mean minimum D, maximum D and V of the coagulations in Group B-2 were significantly larger than those in Group B-1, i.e. 5.3 vs 4.0 cm, 6.6 vs 4.9 cm and 66.9 vs 30.2 cm(3), respectively (p<0.05). The energy efficiencies were also significantly higher in Groups A-2 and B-2 than in Groups A-1 and B-1 (p<0.05). CONCLUSION The Octopus electrodes were more efficient for creating a large ablation zone than clustered electrodes, and the efficacy of RFA with Octopus electrodes can be amplified in the switching monopolar mode.

[1]  L Solbiati,et al.  Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: laboratory and clinical experience in liver metastases. , 1998, Radiology.

[2]  Philippe L Pereira,et al.  Multipolar radiofrequency ablation with internally cooled electrodes: experimental study in ex vivo bovine liver with mathematic modeling. , 2006, Radiology.

[3]  Steven A. Curley,et al.  Radiofrequency Ablation of Hepatocellular Cancer in 110 Patients With Cirrhosis , 2000, Annals of surgery.

[4]  F. Garbagnati,et al.  Percutaneous treatment of small hepatic tumors by an expandable RF needle electrode. , 1998, AJR. American journal of roentgenology.

[5]  Thomas Albrecht,et al.  Multipolar radiofrequency ablation of hepatic tumors: initial experience. , 2005, Radiology.

[6]  J. Joh,et al.  Recurrence and Treatment Pattern in Long-Term Survivors with Hepatocellular Carcinoma: A Comparison between Radiofrequency Ablation and Surgery as a First-line Treatment , 2010, World Journal of Surgery.

[7]  Dieter Haemmerich,et al.  Multiple probe radiofrequency ablation: pilot study in an animal model. , 2003, Journal of vascular and interventional radiology : JVIR.

[8]  J. McGahan,et al.  Radiofrequency ablation of the liver: current status. , 2001, AJR. American journal of roentgenology.

[9]  R W Günther,et al.  Multipolar radiofrequency ablation: first clinical results. , 2004, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[10]  L. Ellis,et al.  Radiofrequency Ablation of Unresectable Primary and Metastatic Hepatic Malignancies: Results in 123 Patients , 1999 .

[11]  Young Hun Choi,et al.  Switching Monopolar Radiofrequency Ablation Technique Using Multiple, Internally Cooled Electrodes and a Multichannel Generator: Ex Vivo and In Vivo Pilot Study , 2007, Investigative radiology.

[12]  T. de Baère,et al.  Radiofrequency ablation of the liver. , 2001, AJR. American journal of roentgenology.

[13]  Intraoperative radiofrequency ablation using a loop internally cooled-perfusion electrode: in vitro and in vivo experiments. , 2006, The Journal of surgical research.

[14]  G. Dodd,et al.  Radiofrequency thermal ablation: computer analysis of the size of the thermal injury created by overlapping ablations. , 2001, AJR. American journal of roentgenology.

[15]  Wei Yang,et al.  Large liver tumors: protocol for radiofrequency ablation and its clinical application in 110 patients--mathematic model, overlapping mode, and electrode placement process. , 2004, Radiology.

[16]  D. Haemmerich,et al.  Multiple applicator approaches for radiofrequency and microwave ablation , 2005, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[17]  Luigi Solbiati,et al.  Treatment of focal liver tumors with percutaneous radio-frequency ablation: complications encountered in a multicenter study. , 2003, Radiology.

[18]  A. Siriwardena,et al.  Radiofrequency ablation of liver tumours: systematic review. , 2004, The Lancet Oncology.

[19]  J. Webster,et al.  Large-volume radiofrequency ablation of ex vivo bovine liver with multiple cooled cluster electrodes. , 2005, Radiology.

[20]  Joon Koo Han,et al.  Multiple-Electrode Radiofrequency Ablation of In Vivo Porcine Liver: Comparative Studies of Consecutive Monopolar, Switching Monopolar Versus Multipolar Modes , 2007, Investigative radiology.

[21]  W R Lees,et al.  Minimally invasive treatment of malignant hepatic tumors: at the threshold of a major breakthrough. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.

[22]  Bin Li,et al.  Meta-analysis of radiofrequency ablation versus hepatic resection for small hepatocellular carcinoma , 2010, BMC gastroenterology.

[23]  A. Rowan Guide for the Care and Use of Laboratory Animals , 1979 .

[24]  Jae Young Lee,et al.  Hepatic Radiofrequency Ablation Using Multiple Probes: Ex Vivo and In Vivo Comparative Studies of Monopolar versus Multipolar Modes , 2006, Korean journal of radiology.