Adaptive multi-element synthetic aperture imaging with motion and phase aberration correction

Multi-element synthetic aperture techniques employing subaperture processing over successive firing steps can produce good image quality with simple front-end hardware but are susceptible to motion and phase aberration artifacts. We explore correlation processing using fully common spatial frequencies of overlapping subapertures to adapt beamforming for motion and phase aberrations. Signals derived from the subset of elements representing common spatial frequencies exhibit significantly higher correlation coefficients than those from signals computed using the entire subaperture. In addition, the correlation coefficient decreases linearly with subaperture separation for complete subaperture signals, but remains nearly constant with subaperture separation if only common spatial frequencies are used. Adaptive multi-element synthetic aperture imaging with correlation processing using fully common spatial frequencies is tested on experimental RF data acquired from a diffuse scattering phantom using a 3.5 MHz, 128-element transducer array. The results indicate that common spatial frequencies can be used efficiently for correlation processing to correct motion and phase aberration for adaptive multi-element synthetic aperture imaging.

[1]  J. Goodman Introduction to Fourier optics , 1969 .

[2]  Takuso Sato,et al.  Imaging through an inhomogeneous layer by least‐mean‐square error fitting , 1984 .

[3]  G. Kino,et al.  Real-Time Digital Image Reconstruction: A Description of Imaging Hardware and an Analysis of Quantization Errors , 1984, IEEE Transactions on Sonics and Ultrasonics.

[4]  R. F. Wagner,et al.  Fundamental correlation lengths of coherent speckle in medical ultrasonic images , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  S. W. Smith,et al.  Phase aberration correction in medical ultrasound using speckle brightness as a quality factor. , 1989, The Journal of the Acoustical Society of America.

[6]  D Rachlin Direct estimation of aberrating delays in pulse-echo imaging systems. , 1990, The Journal of the Acoustical Society of America.

[7]  Mehrdad Soumekh,et al.  Complex phase error and motion estimation in synthetic aperture radar imaging , 1991, Electronic Imaging.

[8]  Raoul Mallart,et al.  The van Cittert–Zernike theorem in pulse echo measurements , 1991 .

[9]  M. O'Donnell,et al.  Correlation-based aberration correction in the presence of inoperable elements , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  M. O'Donnell,et al.  Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  M. Fink,et al.  Time reversal of ultrasonic fields. I. Basic principles , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  G.E. Trahey,et al.  Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. I. Basic principles , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  G. Trahey,et al.  Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. II. Effects of and correction for motion , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  John A. Fawcett,et al.  Synthetic aperture processing for a towed array and a moving source , 1993 .

[15]  M. O'Donnell,et al.  A phase aberration correction method for ultrasound imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  M. O'Donnell,et al.  Influence of missing array elements on phase aberration correction for medical ultrasound , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  R C Waag,et al.  Correction of ultrasonic wavefront distortion using backpropagation and a reference waveform method for time-shift compensation. , 1994, The Journal of the Acoustical Society of America.

[18]  H. Ermert,et al.  Ultrasound synthetic aperture imaging: monostatic approach , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  B. S. Robinson,et al.  Synthetic focus imaging using partial datasets , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[20]  M. O'Donnell,et al.  Synthetic aperture imaging for small scale systems , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  K. Thomenius,et al.  Evolution of ultrasound beamformers , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[22]  Mustafa Karaman,et al.  Beam space processing for low-cost scanners , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[23]  R. Y. Chiao,et al.  Aperture formation on reduced-channel arrays using the transmit-receive apodization matrix , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[24]  Gregg E. Trahey,et al.  Improvement of signal correlation for adaptive imaging using the translating transmit aperture algorithm , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[25]  F.S. Foster,et al.  Optimizing the radiation pattern of sparse periodic two-dimensional arrays , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  M. O'Donnell,et al.  Motion estimation using common spatial frequencies in synthetic aperture imaging , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[27]  Pai-Chi Li,et al.  Optimizing the radiation pattern of sparse periodic linear arrays , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  B. Steinberg,et al.  Deaberration of incoherent wavefront distortion: An approach toward inverse filtering , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  M. O'Donnell,et al.  Synthetic phased arrays for intraluminal imaging of coronary arteries , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[30]  W. Walker,et al.  A speckle target adaptive imaging technique in the presence of distributed aberrations , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[31]  M. O'Donnell,et al.  Improved estimation of phase aberration profiles , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[32]  M. O'Donnell,et al.  Subaperture processing for ultrasonic imaging , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  M. Fink,et al.  Time Reversal of Ultrasonic Fields-Part I : Basic Principles , 2000 .