Distant energy transfer for artificial human implants

The powering of human implants via inductive coupling has been an object of interest for the past two decades. This paper discusses some of the issues concerning a distant energy link used for supplying artificial human implants, operating at the frequency of 13.56 MHz. A procedure for the design of an energy-receiving coil is given for general applications. A design procedure is also developed, with focus on coils used for supplying human implants. The correctness of the analysis of this later design procedure has been verified by experimental results. Measurements with a human tissue simulant also show little deviation from the predictions.

[1]  Bo-Hyung Cho,et al.  An energy transmission system for an artificial heart using leakage inductance compensation of transcutaneous transformer , 1996 .

[2]  Katsuya Hirachi,et al.  Characteristics of a novel energy transmission for a rechargeable cardiac pacemaker by using a resonant DC-DC converter , 1993, Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics.

[3]  Maysam Ghovanloo,et al.  Fully integrated power supply design for wireless biomedical implants , 2002, 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578).

[4]  Marian K. Kazimierczuk,et al.  Self-capacitance of inductors , 1997 .

[5]  Tayfun Akin,et al.  A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode , 1998, IEEE J. Solid State Circuits.

[6]  P. Lawson,et al.  Federal Communications Commission , 2004, Bell Labs Technical Journal.

[7]  Q. Balzano,et al.  Measurement of localized specific absorption rate (SAR) for contactless smartcard readers operating in the HF band , 1998 .

[8]  M. T. Thompson Inductance Calculation Techniques---Part II : Approximations and Handbook Methods , 1991 .

[9]  S. Pourmehdi,et al.  An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscle , 1998, IEEE Transactions on Biomedical Engineering.

[10]  Magdy F. Iskander,et al.  An Empirical Formula for Broad-Band SAR Calculations of Prolate Spheroidal Models of Humans and Animals , 1979 .

[11]  Wilfried Mokwa,et al.  Micro coils for improved power transfer in telemetry systems , 2002, 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578).

[12]  H. Matsuki,et al.  Flexible transcutaneous transformer for artificial heart system , 1990 .

[13]  S. Ramo,et al.  Fields and Waves in Communication Electronics , 1966 .