Calculation of conversion coefficients using Chinese adult reference phantoms for air submersion and ground contamination

The effective and organ equivalent dose coefficients have been widely used to provide assessment of doses received by adult members of the public and by workers exposed to environmental radiation from nuclear facilities under normal or accidental situations. Advancements in phantom types, weighting factors, decay data, etc, have led to the publication of newer results in this regard. This paper presents a new set of conversion coefficients for air submersion and ground contamination (with the use of Geant4) for photons from 15 keV to 10 MeV using the Chinese and International Commission on Radiological Protection (ICRP) adult reference male and female phantoms. The radiation fields, except for energy spectrum at low energies, were validated by the data obtained from the Monte Carlo code YURI. The effective dose coefficients of monoenergetic photons, obtained for the ICRP adult reference phantoms, agree well with recently published data for air submersion and ground contamination with a plane source at a depth of 0.5 g cm−2 in soil, but an average difference of 36.5% is observed for ground surface contamination with the abovementioned radiation field. The average differences in organ equivalent dose coefficients between the Chinese and the ICRP adult reference phantoms are within 6% for most organs, but noticeable differences of up to 70% or even higher are found at photon energies below 30 keV under air submersion. The effective dose coefficients obtained with the Chinese adult reference phantoms are greater than those of the ICRP adult reference phantoms above 30 keV and 0.5 MeV for ground contamination and air submersion, respectively; the average differences from the Chinese adult reference phantoms are about 3.6% and 0.4% in the whole energy range with maximum differences of 31.8% and 27.6% at 15 keV for air submersion and ground contamination respectively. These differences are attributed to anatomical discrepancies in overlying tissue mass of an individual organ and the body mass between the Chinese and the ICRP adult reference phantoms. These monoenergetic photon conversion coefficients are subsequently used to evaluate radionuclides with decay data from ICRP publication 107.

[1]  K. G. Veinot,et al.  Effective Dose Rate Coefficients for Immersions in Radioactive Air and Water , 2016, Radiation protection dosimetry.

[2]  K. G. Veinot,et al.  COMPARISON OF MONOENERGETIC PHOTON ORGAN DOSE RATE COEFFICIENTS FOR STYLIZED AND VOXEL PHANTOMS SUBMERGED IN AIR. , 2016, Radiation protection dosimetry.

[3]  Choonsik Lee,et al.  Age-dependent dose conversion coefficients for external exposure to radioactive cesium in soil , 2016 .

[4]  B. Askri Application of optimized geometry for the Monte Carlo simulation of a gamma-ray field in air created by sources distributed in the ground , 2015 .

[5]  G. Cho,et al.  External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting , 2013, Radiation protection dosimetry.

[6]  H. Schlattl,et al.  Organ doses from environmental exposures calculated using voxel phantoms of adults and children , 2012, Physics in medicine and biology.

[7]  H. Schlattl,et al.  Effective dose conversion coefficients for radionuclides exponentially distributed in the ground , 2012, Radiation and Environmental Biophysics.

[8]  N Petoussi-Henss,et al.  Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures , 2010, Annals of the ICRP.

[9]  Rui Qiu,et al.  An ICRP-based Chinese adult male voxel model and its absorbed dose for idealized photon exposures—the skeleton , 2009, Physics in medicine and biology.

[10]  Ren-wang Li,et al.  Organ dose conversion coefficients on an ICRP-based Chinese adult male voxel model from idealized external photons exposures , 2009, Physics in medicine and biology.

[11]  J. Valentin,et al.  Nuclear decay data for dosimetric calculations , 2009 .

[12]  Paul DeLuca,et al.  Realistic reference phantoms: An ICRP/ICRU joint effort , 2009, Annals of the ICRP.

[13]  R. Vetter ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection , 2008 .

[14]  Computation of conversion coefficients relating air Kerma to Hp(0.07,α), Hp(10,α), and for x‐ray narrow spectrum from 40 to 140 kV , 2004 .

[15]  A. Dell'Acqua,et al.  Geant4 - A simulation toolkit , 2003 .

[16]  Generic Models for Use in Assessing the Impact of Discharges of Radioactive Substances to the Environment , 2002, Kerntechnik.

[17]  K. Eckerman,et al.  Reference Man Models for Males and Females of Six Age Groups of Asian Populations , 1998 .

[18]  K. F. Eckerman,et al.  External exposure to radionuclides in air, water, and soil , 1996 .

[19]  Kimiaki Saito,et al.  Gamma Ray Fields in the Air Due to Sources in the Ground , 1995 .

[20]  Kimiaki Saito,et al.  Organ Doses as a Function of Body Weight for Environmental Gamma Rays , 1991 .

[21]  Kimiaki Saito,et al.  Organ Doses for Foetuses, Babies, Children and Adults from Environmental Gamma Rays , 1991 .

[22]  C. Wernli Development of a TL Dosemeter to Measure the New ICRU Dose Quantities H'(10) and H'(0.07) in Environmental Dosimetry , 1990 .

[23]  K. F. Eckerman,et al.  Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn , 1987 .

[24]  H. Paretzke,et al.  Effective Dose Equivalents for Photon Exposures from Plane Sources on the Ground , 1986 .

[25]  L. Koblinger,et al.  Calculations on the relationship between gamma source distributions in the soil and external doses. , 1985, The Science of the total environment.

[26]  Kimiaki Saito,et al.  Development of a Monte Carlo code for the calculation of gamma ray transport in the natural environment , 1985 .