A Passive Islanding Detection Technique for Grid-Connected Photovoltaic Inverters

One of the problem associated with grid connected distribution generator is islanding, which occurs when a disconnected distribution generator is energized unintentionally. If islanding is not detected quickly it could pose a serious threat to the distribution generator and to the personnel working. The islanding methods that are available use system parameter to distinguish between islanding and non-islanding condition. This paper presents a passive islanding detection method based on the difference of ripple content of voltage at the point of common coupling during non-islanding and islanding period. Islanding is detected whenever the ripple content of the voltage at point of common coupling breaches the set threshold level for fixed period of time. This method distinguishes the islanding condition from the other grid disturbances efficiently and detects whenever an islanding occurs. The various islanding and non-islanding condition were simulated to test the working of this method. It was inferred that the proposed method did not exhibit any non-detection zone and was able to detect all types of islanding cases within 300ms of the allowed delay time.Theoretical analysis and simulation results are presented to validate the proposed method.

[1]  Zhe Chen,et al.  Review of islanding detection methods for distributed generation , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[2]  Haritza Camblong,et al.  Survey on microgrids: Unplanned islanding and related inverter control techniques , 2011 .

[3]  Reza Noroozian,et al.  Anti-Islanding Scheme for Synchronous DG Units Based on Tufts–Kumaresan Signal Estimation Method , 2013, IEEE Transactions on Power Delivery.

[4]  N.W. Miller,et al.  Distributed generation islanding-implications on power system dynamic performance , 2002, IEEE Power Engineering Society Summer Meeting,.

[5]  Rami J. Haddad,et al.  Voltage Ripple-Based Passive Islanding Detection Technique for Grid-Connected Photovoltaic Inverters , 2016, IEEE Power and Energy Technology Systems Journal.

[6]  Ehab F. El-Saadany,et al.  Islanding detection of grid connected distributed generators using TLS-ESPRIT , 2007 .

[7]  Linfeng Zhang,et al.  Energy management in a microgrid with distributed energy resources , 2014 .

[8]  Zhengming Zhao,et al.  Grid-connected photovoltaic power systems: Technical and potential problems—A review , 2010 .

[9]  Ajeet Rohatgi,et al.  Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones , 2000 .

[10]  Shyh-Jier Huang,et al.  Enhancement of islanding-detection of distributed generation systems via wavelet transform-based approaches , 2008 .

[11]  Hurng-Liahng Jou,et al.  Active islanding detection method for inverter-based distribution generation power system , 2012 .

[12]  S. Samantaray,et al.  Wavelet Singular Entropy-Based Islanding Detection in Distributed Generation , 2013, IEEE Transactions on Power Delivery.

[13]  M. Karrari,et al.  Application of Duffing Oscillators for Passive Islanding Detection of Inverter-Based Distributed Generation Units , 2012, IEEE Transactions on Power Delivery.

[14]  W. Bower,et al.  Evaluation of Islanding Detection Methods for Utility-Interactive Inverters in Photovoltaic Systems , 2002 .