Solid-State Microelectrodes for Flow-Cell Analysis Based on Planar Back-Side Contact Transducers

This paper presents an overview of the studies carried out in the recent years in our laboratory, on the construction of different solid-state microelectrodes for flow-cell analysis. The microelectrodes were based on planar transducers made from a printed circuit board and manufactured as back-side contact structures, which facilitate their mounting in a flow-cell. Performances of the polymeric membrane ion-selective: coated-wire microelectrodes and microsensors with a polyHEMA layer containing internal electrolyte are compared. Conducting polymer – polypyrrole doped with ester of sulfosuccinic acid – was added to the PVC membranes to develop all-solid-state microelectrodes without internal electrolyte solution, exhibiting good potential stability in time. Finally, all-solid-state reference microelectrodes based on back-side contact transducers are prepared and examined. These structures were applied as reference electrodes in flow-cell measurements with potassium-selective planar microelectrodes.

[1]  Isao Karube,et al.  Microfabricated Liquid Junction Ag/AgCl Reference Electrode and Its Application to a One-Chip Potentiometric Sensor , 1999 .

[2]  H. J. James,et al.  Coated wire ion-selective electrodes. , 1971, Analytical chemistry.

[3]  A. Ivaska,et al.  Characterization of a single-piece all-solid-state lithium-selective electrode based on soluble conducting polyaniline , 1999 .

[4]  D. Pijanowska,et al.  Design of miniaturized nitrite sensors based on silicon structure with back-side contacts , 2002 .

[5]  R. E. Gyurcsányi,et al.  Microfabricated ISEs: critical comparison of inherently conducting polymer and hydrogel based inner contacts. , 2004, Talanta.

[6]  A. Lewenstam,et al.  Junction-less reference electrode for potentiometric measurements obtained by buffering pH in a conducting polymer matrix. , 2005, The Analyst.

[7]  U. Schnakenberg,et al.  Miniaturized ion-selective chip electrode for sensor application. , 1997, Analytical chemistry.

[8]  A. Dybko,et al.  Miniaturized back-side contact transducer for potentiometric sensors , 2003 .

[9]  A. Dybko,et al.  Planar potentiometric sensors based on Au and Ag microelectrodes and conducting polymers for flow-cell analysis , 2005 .

[10]  Michael R. Neuman,et al.  Microfabricated sensor arrays sensitive to pH and K+ for ionic distribution measurements in the beating heart , 1995 .

[11]  H. Freiser,et al.  Ion-Selective Electrodes in Analytical Chemistry , 1980 .

[12]  A. Michalska,et al.  All-solid-state planar miniature ion-selective chloride electrode , 2002 .

[13]  A. Michalska,et al.  All-Solid-State Potentiometric Sensors for Potassium and Sodium Based on Poly(pyrrole) Solid Contact , 1997 .

[14]  M. Chudy,et al.  Nitrate-selective chemically modified field effect transistors for flow-cell applications , 2000 .

[15]  Dermot Diamond,et al.  Evaluation of miniaturised solid state reference electrodes on a silicon based component , 1997 .

[16]  Johan Bobacka,et al.  Potentiometric Ion Sensors Based on Conducting Polymers , 2003 .

[17]  J. Bobacka Conducting Polymer‐Based Solid‐State Ion‐Selective Electrodes , 2006 .

[18]  M. Chudy,et al.  Novel head for testing and measurement of chemical microsensors , 2001 .

[19]  Anthony Turner,et al.  Solvent-resistant carbon electrodes screen printed onto plastic for use in biosensors , 1997 .

[20]  A. Michalska,et al.  Optimizing the analytical performance and construction of ion-selective electrodes with conducting polymer-based ion-to-electron transducers , 2005, Analytical and bioanalytical chemistry.

[21]  Zbigniew Brzozka,et al.  Technological aspects of potentiometric BSC-type microsensor fabrication , 2001, Optoelectronic and Electronic Sensors.

[22]  N. Ito,et al.  Development of a micro-planar Ag/AgCl quasi-reference electrode with long-term stability for an amperometric glucose sensor , 2002 .

[23]  Isao Karube,et al.  Micromachined liquid-junction Ag/AgCl reference electrode , 1998 .

[24]  K. Jang,et al.  High molecular weight soluble polypyrrole , 2001 .

[25]  Microfabrication technology of flexible membrane based sensors for in vivo applications , 1995 .

[26]  Artur Dybko,et al.  All-solid-state miniaturised planar reference electrodes based on ionic liquids , 2006 .

[27]  Johan Bobacka,et al.  Single-piece all-solid-state ion-selective electrode , 1995 .

[28]  E. Bakker Hydrophobic Membranes as Liquid Junction-Free Reference Electrodes , 1999 .

[29]  A. Dybko,et al.  Miniaturised all-solid-state potentiometric ion sensors based on PVC-membranes containing conducting polymers , 2004 .

[30]  Robert Koncki,et al.  Screen-printed reference electrodes for potentiometric measurements , 2004 .

[31]  Coated wire ion-selective electrodes and their application to environmental problems , 1987 .

[32]  Michael J. Schöning,et al.  New concepts of miniaturised reference electrodes in silicon technology for potentiometric sensor systems , 2004 .

[33]  Ernö Pretsch,et al.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics. , 1997, Chemical reviews.