Automatic Analysis of Composite Physical Signals Using Non-Negative Factorization and Information Criterion

In time-resolved spectroscopy, composite signal sequences representing energy transfer in fluorescence materials are measured, and the physical characteristics of the materials are analyzed. Each signal sequence is represented by a sum of non-negative signal components, which are expressed by model functions. For analyzing the physical characteristics of a measured signal sequence, the parameters of the model functions are estimated. Furthermore, in order to quantitatively analyze real measurement data and to reduce the risk of improper decisions, it is necessary to obtain the statistical characteristics from several sequences rather than just a single sequence. In the present paper, we propose an automatic method by which to analyze composite signals using non-negative factorization and an information criterion. The proposed method decomposes the composite signal sequences using non-negative factorization subjected to parametric base functions. The number of components (i.e., rank) is also estimated using Akaike's information criterion. Experiments using simulated and real data reveal that the proposed method automatically estimates the acceptable ranks and parameters.

[1]  N. Sugiura Further analysts of the data by akaike' s information criterion and the finite corrections , 1978 .

[2]  Måns Ehrenberg,et al.  Rotational brownian motion and fluorescence intensify fluctuations , 1974 .

[3]  Mark D. Plumbley Algorithms for nonnegative independent component analysis , 2003, IEEE Trans. Neural Networks.

[4]  H. Sebastian Seung,et al.  Learning the parts of objects by non-negative matrix factorization , 1999, Nature.

[5]  Takio Kurita,et al.  Automatic Factorization of Biological Signals Measured by Fluorescence Correlation Spectroscopy Using Non-negative Matrix Factorization , 2007, ICONIP.

[6]  Elisa Collado-Fregoso,et al.  Excited-state dynamics of nitrated push-pull molecules: the importance of the relative energy of the singlet and triplet manifolds. , 2009, The journal of physical chemistry. A.

[7]  Takio Kurita,et al.  Automatic factorization of biological signals by using Boltzmann non-negative matrix factorization , 2008, 2008 IEEE International Joint Conference on Neural Networks (IEEE World Congress on Computational Intelligence).

[8]  H. Akaike A new look at the statistical model identification , 1974 .

[9]  O. Krichevsky,et al.  Fluorescence correlation spectroscopy: the technique and its applications , 2002 .

[10]  Terrence J. Sejnowski,et al.  Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis , 2007, NeuroImage.

[11]  T. Markvart,et al.  Excitation energy transfer rate from Langmuir Blodgett (LB) dye monolayers to silicon: Effect of aggregate formation , 2010 .

[12]  H. Sebastian Seung,et al.  Algorithms for Non-negative Matrix Factorization , 2000, NIPS.

[13]  J. Rissanen Stochastic Complexity and Modeling , 1986 .

[14]  Hiroshi Kimura,et al.  Cytosolic chaperonin prevents polyglutamine toxicity with altering the aggregation state , 2006, Nature Cell Biology.

[15]  Pierre Comon,et al.  Independent component analysis, A new concept? , 1994, Signal Process..

[16]  Rajesh Langoju,et al.  Stochastic approach to data analysis in fluorescence correlation spectroscopy. , 2006, The journal of physical chemistry. A.

[17]  J. Rissanen A UNIVERSAL PRIOR FOR INTEGERS AND ESTIMATION BY MINIMUM DESCRIPTION LENGTH , 1983 .

[18]  Dennis E. Koppel,et al.  Statistical accuracy in fluorescence correlation spectroscopy , 1974 .

[19]  P. Paatero,et al.  Positive matrix factorization: A non-negative factor model with optimal utilization of error estimates of data values† , 1994 .

[20]  Karl Pearson F.R.S. LIII. On lines and planes of closest fit to systems of points in space , 1901 .

[21]  E. Elson,et al.  Fluorescence correlation spectroscopy. I. Conceptual basis and theory , 1974 .

[22]  Mamoru Tamura,et al.  Molecular dynamics of STAT3 on IL-6 signaling pathway in living cells. , 2004, Biochemical and biophysical research communications.

[23]  J. Shao Linear Model Selection by Cross-validation , 1993 .

[24]  H. Rigneault,et al.  Fluorescence correlation spectroscopy. , 2011, Methods in molecular biology.

[25]  R. Rigler,et al.  Fluorescence correlation spectroscopy , 2001 .

[26]  B. Wielgus-Kutrowska,et al.  The comparison of aggregation and folding of enhanced green fluorescent protein (EGFP) by spectroscopic studies , 2010 .