A one-degree-of-freedom spherical mechanism for human knee joint modelling

In-depth comprehension of human knee kinematics is necessary in prosthesis and orthosis design and in surgical planning but requires complex mathematical models. Models based on one-degree-of-freedom equivalent mechanisms have replicated well the passive relative motion between the femur and tibia, i.e. the knee joint motion in virtually unloaded conditions. In these mechanisms, fibres within the anterior and posterior cruciate and medial collateral ligaments were taken as isometric and anatomical articulating surfaces as rigid. A new one-degree-of-freedom mechanism is analysed in the present study, which includes isometric fibres within the two cruciates and a spherical pair at the pivot point of the nearly spherical motion as measured for this joint. Bounded optimization was applied to the mechanism to refine parameter first estimates from experimental measurements on four lower-limb specimens and to best-fit the experimental motion of these knees. Relevant results from computer simulations were compared with those from one previous equivalent mechanism, which proved to be very accurate in a former investigation. The spherical mechanism represented knee motion with good accuracy, despite its simple structure. With respect to the previous more complex mechanism, the less satisfactory results in terms of replication of natural motion were counterbalanced by a reduction of computational costs, by an improvement in numerical stability of the mathematical model, and by a reduction of the overall mechanical complexity of the mechanism. These advantages can make the new mechanism preferable to the previous ones in certain applications, such as the design of prostheses, orthoses, and exoskeletons, and musculoskeletal modelling of the lower limb.

[1]  A Leardini,et al.  Articular surface approximation in equivalent spatial parallel mechanism models of the human knee joint: An experiment-based assessment , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  Jaime Prat Pastor,et al.  Development of a hinge compatible with the kinematics of the knee joint , 2007, Prosthetics and orthotics international.

[3]  A. Leardini,et al.  Patellar tracking during total knee arthroplasty: an in vitro feasibility study , 2007, Knee Surgery, Sports Traumatology, Arthroscopy.

[4]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[5]  S Amiri,et al.  Mechanics of the passive knee joint. Part 2: Interaction between the ligaments and the articular surfaces in guiding the joint motion , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[6]  J O Galante,et al.  Model studies of the stiffness characteristics of the human knee joint. , 1983, Journal of biomechanics.

[7]  F. Fuss Anatomy of the cruciate ligaments and their function in extension and flexion of the human knee joint. , 1989, The American journal of anatomy.

[8]  P S Walker,et al.  Design forms of total knee replacement , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[9]  V. Pinskerova,et al.  Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee , 2000 .

[10]  A E Engin,et al.  Three-body segment dynamic model of the human knee. , 1993, Journal of biomechanical engineering.

[11]  V. Parenti-Castelli,et al.  A spatial mechanism with higher pairs for modelling the human knee joint. , 2003, Journal of biomechanical engineering.

[12]  Raffaele Di Gregorio,et al.  On the Modeling of Passive Motion of the Human Knee Joint by Means of Equivalent Planar and Spatial Parallel Mechanisms , 2004, Auton. Robots.

[13]  Nicola Sancisi,et al.  A 1-Dof parallel spherical wrist for the modelling of the knee passive motion , 2010 .

[14]  Victor Sholukha,et al.  Double-step registration of in vivo stereophotogrammetry with both in vitro 6-DOFs electrogoniometry and CT medical imaging. , 2006, Journal of biomechanics.

[15]  J. Apkarian,et al.  A three-dimensional kinematic and dynamic model of the lower limb. , 1989, Journal of biomechanics.

[16]  L. Blankevoort,et al.  The envelope of passive knee joint motion. , 1988, Journal of biomechanics.

[17]  J. O'Connor,et al.  The mechanics of the knee and prosthesis design. , 1978, The Journal of bone and joint surgery. British volume.

[18]  Vincenzo Parenti-Castelli,et al.  PARALLEL MECHANISMS APPLIED TO THE HUMAN KNEE PASSIVE MOTION SIMULATION , 2000 .

[19]  N E Akalan,et al.  Three-dimensional knee model: constrained by isometric ligament bundles and experimentally obtained tibio-femoral contacts. , 2008, Journal of biomechanics.

[20]  E. Abdel-Rahman,et al.  A two-dimensional dynamic anatomical model of the human knee joint. , 1993, Journal of biomechanical engineering.

[21]  M. Pandy,et al.  Muscle, ligament, and joint-contact forces at the knee during walking. , 2005, Medicine and science in sports and exercise.

[22]  John J. O'Connor,et al.  A three-dimensional geometric model of the knee for the study of joint forces in gait , 1997 .

[23]  F. Rannou,et al.  Role of bracing in the management of knee osteoarthritis , 2010, Current opinion in rheumatology.

[24]  Scott L. Delp,et al.  A Model of the Lower Limb for Analysis of Human Movement , 2010, Annals of Biomedical Engineering.

[25]  S Amiri,et al.  Mechanics of the passive knee joint. Part 1: The role of the tibial articular surfaces in guiding the passive motion , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[26]  J Wismans,et al.  A three-dimensional mathematical model of the knee-joint. , 1980, Journal of biomechanics.

[27]  P S Walker,et al.  Future directions in knee replacement , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[28]  H. Grootenboer,et al.  Articular contact in a three-dimensional model of the knee. , 1991, Journal of Biomechanics.

[29]  Wang Gui-hua,et al.  Data-processing and error analysis in vacuum gauge calibration , 2006 .

[30]  A A Amis,et al.  Knee joint motion: Description and measurement , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[31]  P S Walker,et al.  A new concept in guided motion total knee arthroplasty. , 2001, The Journal of arthroplasty.

[32]  Jennifer M Scarvell,et al.  Development of the concepts of knee kinematics. , 2003, Archives of physical medicine and rehabilitation.

[33]  A. Leardini,et al.  Review: Diarthrodial Joints-Kinematic Pairs, Mechanisms or Flexible Structures? , 1998, Computer methods in biomechanics and biomedical engineering.

[34]  J. S. Rovick,et al.  Relation between knee motion and ligament length patterns. , 1991, Clinical biomechanics.