Cardiac output and blood pressure during active and passive standing.

The present study compared the haemodynamic pattern of active and passive standing. We used non-invasive techniques with beat-to-beat evaluation of blood pressure, heart rate and stroke volume. Seven healthy subjects, aged 24-41 (mean 30) years were examined. Finger blood pressure was continuously recorded by volume clamp technique (Finapres), and simultaneous beat-to-beat beat stroke volume was obtained, using an ultrasound Doppler technique, from the product of the valvular area and the aortic flow velocity time integral in the ascending aorta from the suprasternal notch. Measurements were performed at rest, during active standing and following passive tilt (60 degrees). Active standing caused a transient but greater reduction of blood pressure and a higher increase of heart rate than passive tilt during the first 30s (delta mean blood pressure: -39 +/- 10 vs. -16 +/- 7 mmHg, delta heart rate: 35 +/- 8 vs. 12 +/- 7 beats m-1 (active standing vs. passive tilt; P < 0.01). There was a significantly larger increase in cardiac output during active standing (37 +/- 24 vs. 0 +/- 15%, P < 0.01) and a more marked decrease in total peripheral resistance (-58 +/- 11 vs. -16 +/- 17%, P < 0.01). A precipitous rise in intra-abdominal pressure (43 +/- 22 mmHg) could be observed upon rising only in active standing. This was interpreted as an indication of translocation of blood to the thorax. There was no significant difference in haemodynamic changes during the later stage of standing (1-7 min) between both manoeuvres. These results suggest that active standing causes a marked blood pressure reduction in the initial phase which seems to reflect systemic vasodilatation caused by activation of cardiopulmonary baroreflexes, probably due to a rapid shift of blood from the splanchnic vessels in addition to the shift from muscular vessels associated with abdominal and calf muscle contraction. Moreover, the ultrasound Doppler technique was found to be a more adequate method for rapid beat-to-beat evaluation of cardiac output during orthostatic manoeuvres.

[1]  R. F. Rushmer The nature of intraperitoneal and intrarectal pressures. , 1946, The American journal of physiology.

[2]  R. Gardner,et al.  Clinical Comparison of Pressure‐Pulse and Indicator‐Dilution Cardiac Output Determination , 1980, Circulation.

[3]  A. J. Dunning,et al.  Mechanisms of initial blood pressure response to postural change. , 1984, Clinical science.

[4]  G. Reiss,et al.  Scanning tunneling microscopy on rough surfaces‐quantitative image analysis , 1991 .

[5]  B. Wranne,et al.  Cardiac output determined by ultrasound-Doppler: clinical applications. , 1990, Clinical physiology.

[6]  M. Nordin,et al.  Intra-abdominal pressure measurements using a wireless radio pressure pill and two wire connected pressure transducers: a comparison. , 1984, Scandinavian journal of rehabilitation medicine.

[7]  H. Tanaka,et al.  Circulatory responses in children with unexplained syncope evaluated by continuous non‐invasive finger blood pressure monitoring , 1994, Acta paediatrica.

[8]  J. R. Ledsome,et al.  The effects of distension of the pulmonary vein—atrial junctions upon peripheral vascular resistance , 1970, The Journal of physiology.

[9]  J. V. van Lieshout,et al.  Spectrum of orthostatic disorders: classification based on an analysis of the short-term circulatory response upon standing. , 1991, Clinical science.

[10]  H. Tanaka,et al.  Effect of temperature on finger artery pressure evaluated by volume clamp technique. , 1993, Clinical physiology.

[11]  M. Borres,et al.  Blood pressure responses in Japanese and Swedish children in the supine and standing position. , 1994, European heart journal.

[12]  J. Mitchell,et al.  Effects of partial neuromuscular blockade on sympathetic nerve responses to static exercise in humans. , 1989, Circulation research.

[13]  S. Bevegård Studies on the regulation of the circulation in man. With special reference to the stroke volume and the effect of muscular work, body position and artificially induced variations of the heart rate. , 1962, Acta physiologica Scandinavica. Supplementum.

[14]  S Simonsen,et al.  Determination of cardiac output by Doppler echocardiography. , 1984, British heart journal.

[15]  D. Clement,et al.  Influence of Muscle Afferents on Cutaneous and Muscle Vessels in the Dog , 1974 .

[16]  R. Hainsworth Reflexes from the heart. , 1991, Physiological reviews.

[17]  E. Greene,et al.  Comparison of noninvasive pulsed Doppler and Fick measurements of stroke volume in cardiac patients. , 1984, American heart journal.

[18]  E. Bennett,et al.  Validation of a Doppler technique for beat-to-beat measurement of cardiac output. , 1985, Clinical science.

[19]  H Ihlen,et al.  Cardiac stroke volume during exercise measured by Doppler echocardiography: comparison with the thermodilution technique and evaluation of reproducibility. , 1987, British heart journal.

[20]  U. Scherrer,et al.  Relation Between Sympathetic Outflow and Vascular Resistance in the Calf During Perturbations in Central Venous Pressure: Evidence for Cardiopulmonary Afferent Regulation of Calf Vascular Resistance in Humans , 1989, Circulation research.

[21]  J T Shepherd,et al.  Reaction in man of resistance and capacity vessels in forearm and hand to leg exercise. , 1966, Journal of applied physiology.