A novel instrument for studying the flow behaviour of erythrocytes through microchannels simulating human blood capillaries.

A novel instrument has been developed to study the microrheology of erythrocytes as they flow through channels of dimensions similar to human blood capillaries. The channels are produced in silicon substrates using microengineering technology. Accurately defined, physiological driving pressures and temperatures are employed whilst precise, real-time image processing allows individual cells to be monitored continuously during their transit. The instrument characterises each cell in a sample of ca. 1000 in terms of its volume and flow velocity profile during its transit through a channel. The unique representation of the data in volume/velocity space provides new insight into the microrheological behaviour of blood. The image processing and subsequent data analysis enable the system to reject anomalous events such as multiple cell transits, thereby ensuring integrity of the resulting data. By employing an array of microfluidic flow channels we can integrate a number of different but precise and highly reproducible channel sizes and geometries within one array, thereby allowing multiple, concurrent isobaric measurements on one sample. As an illustration of the performance of the system, volume/velocity data sets recorded in a microfluidic device incorporating multiple channels of 100 microns length and individual widths ranging between 3.0 and 4.0 microns are presented.

[1]  W. Reinhart The influence of iron deficiency on erythrocyte deformability , 1992, British journal of haematology.

[2]  L J Kricka,et al.  Manipulation and flow of biological fluids in straight channels micromachined in silicon. , 1994, Clinical chemistry.

[3]  T C Fisher,et al.  Pulse shape analysis of RBC micropore flow via new software for the cell transit analyser (CTA). , 1992, Biorheology.

[4]  G. Nash,et al.  Micropipette methods for analysing blood cell rheology and their application to clinical research , 1993 .

[5]  P. Kaye,et al.  A silicon micromachined device for use in blood cell deformability studies , 1995, IEEE Transactions on Biomedical Engineering.

[6]  S. Chien,et al.  Evaluation of red blood cell filterability test: influences of pore size, hematocrit level, and flow rate. , 1984, Journal of Laboratory and Clinical Medicine.

[7]  H. Ohki,et al.  Optically accessible microchannels formed in a single-crystal silicon substrate for studies of blood rheology. , 1992, Microvascular research.

[8]  T. Secomb,et al.  Motion of red blood cells in capillaries with variable cross-sections. , 1996, Journal of biomechanical engineering.

[9]  Y Kikuchi,et al.  Microchannels made on silicon wafer for measurement of flow properties of blood cells , 1989 .

[10]  S. Persson,et al.  Studies on red cell filterability: Significance of buffer media , 1991 .

[11]  G. Nash Filterability of blood cells: methods and clinical applications. , 1990, Biorheology.

[12]  G. Cokelet,et al.  Fabrication of in vitro microvascular blood flow systems by photolithography. , 1993, Microvascular research.

[13]  F. Jung,et al.  A new device for the routine measurement of erythrocyte deformability. , 1984, Biorheology. Supplement : the official journal of the International Society of Biorheology.

[14]  H. Schmid-schönbein,et al.  The single erythrocyte rigidometer (SER) as a reference for RBC deformability. , 1982, Biorheology.