Development of a force-reflecting robotic platform for cardiac catheter navigation.

Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway.

[1]  Laura Cercenelli,et al.  Initial Experience With a Telerobotic System to Remotely Navigate and Automatically Reposition Standard Steerable EP Catheters , 2007, ASAIO journal.

[2]  Farrokh Janabi-Sharifi,et al.  Robot-assisted catheter manipulation for intracardiac navigation , 2009, International Journal of Computer Assisted Radiology and Surgery.

[3]  Rajnikant V. Patel,et al.  Autonomous Image-Guided Robot-Assisted Active Catheter Insertion , 2008, IEEE Transactions on Robotics.

[4]  Rajnikant V. Patel,et al.  Robot-assisted Active Catheter Insertion: Algorithms and Experiments , 2009, Int. J. Robotics Res..

[5]  F. Morady Radio-frequency ablation as treatment for cardiac arrhythmias. , 1999, The New England journal of medicine.

[6]  Maria Drangova,et al.  Design and Performance Evaluation of a Remote Catheter Navigation System , 2009, IEEE Transactions on Biomedical Engineering.

[7]  P. Novak Effectiveness of catheter ablation versus antiarrhythmic drug therapy for atrial fibrillation , 2009, Current opinion in cardiology.

[8]  L. Epstein,et al.  Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms. , 1994, Circulation.

[9]  S. Ernst,et al.  Initial Experience With Remote Catheter Ablation Using a Novel Magnetic Navigation System: Magnetic Remote Catheter Ablation , 2004, Circulation.

[10]  Todd J Cohen,et al.  Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics. , 2008, The Journal of invasive cardiology.