Combustion and NOx emission characteristics of a retrofitted down-fired 660 MWe utility boiler at different loads
暂无分享,去创建一个
Zhichao Chen | Qunyi Zhu | Zhengqi Li | Zhengqi Li | Zhichao Chen | Qunyi Zhu | Feng Ren | Guangkui Liu | Feng Ren | Guangkui Liu
[1] V. I. Kouprianov,et al. Optimization of excess air for the improvement of environmental performance of a 150 MW boiler fired with Thai lignite , 2003 .
[2] Shien Hui,et al. NOx emission and thermal efficiency of a 300 MWe utility boiler retrofitted by air staging , 2009 .
[3] Jie Zhang,et al. Influence of vent air valve opening on combustion characteristics of a down-fired pulverized-coal 300 MWe utility boiler , 2007 .
[4] J. L. T. Azevedo,et al. Measurements of gas species, temperature, and char burnout in a low-no x pulverized-coal-fired utility boiler , 2003 .
[5] Zengying Liang,et al. The energy consumption and environmental impacts of SCR technology in China , 2011 .
[6] S. Rui,et al. Experimental study of the combustion efficiency and formation of NOx in an industrial pulverized coal combustor , 2004 .
[7] Zhengqi Li,et al. Influence of the Down-Draft Secondary Air on the Furnace Aerodynamic Characteristics of a Down-Fired Boiler , 2009 .
[8] Ds De,et al. Measurement of flame temperature with a multi-element thermocouple - reply , 1982 .
[9] Z. Ge,et al. Combustion Characteristics and NO x Emissions of Two Kinds of Swirl Burners in a 300-MWe Wall-Fired Pulverized-Coal Utility Boiler , 2008 .
[10] J. L. T. Azevedo,et al. Combustion Characteristics of a Front-Wall-Fired Pulverized-Coal 300 MWe Utility Boiler , 1997 .
[11] Zhichao Chen,et al. Improved NOx emissions and combustion characteristics for a retrofitted down-fired 300-MWe utility boiler. , 2010, Environmental science & technology.
[12] M. S. Hegde,et al. Catalysis for NOx abatement , 2009 .
[13] Zhichao Chen,et al. Influence of declivitous secondary air on combustion characteristics of a down-fired 300-MWe utility boiler , 2010 .
[14] Zhengqi Li,et al. Experimental Investigations into Gas/Particle Flows in a Down-Fired Boiler: Influence of the Vent Air Ratio , 2010 .
[15] Zhichao Chen,et al. Influence of the overfire air ratio on the NO(x) emission and combustion characteristics of a down-fired 300-MW(e) utility boiler. , 2010, Environmental science & technology.
[16] Pauli Dernjatin,et al. Reducing the minimum load and NOx emissions for lignite-fired boiler by applying a stable-flame concept , 2003 .
[17] Zhao Chen,et al. Influence of oil-atomized air on flow and combustion characteristics in a 300 MWe down-fired boiler , 2009 .
[18] Zhichao Chen,et al. Measurement of gas species, temperatures, char burnout, and wall heat fluxes in a 200-MWe lignite-fired boiler at different loads , 2010 .
[19] J. Azevedo,et al. EXPERIMENTAL CHARACTERIZATION OF AN INDUSTRIAL PULVERIZED COAL-FIRED FURNACE UNDER DEEP STAGING CONDITIONS , 2007 .
[20] Pd Sunavala,et al. Measurement of flame temperature with a multi-element thermocouple , 1982 .
[21] Zhichao Chen,et al. Influence of the adjustable vane position on the flow and combustion characteristics of a down-fired pulverized-coal 300 MWe utility boiler , 2008 .