Practical methods for retrace error correction in nonnull aspheric testing.

Nonnull test is often adopted for aspheric testing. But due to its violation of null condition, the testing rays will follow different paths from the reference and aberrations from the interferometer will not cancel out, leading to widely difference between the obtained surface figure and that of the real, which is called the Retrace-error accordingly. In this paper, retrace error of nonnull aspheric testing is analyzed in detail with conclusions that retrace error has much to do with the aperture, F number and surface shape error of the aspheric under test. Correcting methods are proposed according to the manner of the retrace errors. Both computer simulation and experimental results show that the proposed methods can correct the retrace error effectively. The analysis and proposed correction methods bring much to the application of nonnull aspheric testing.

[1]  J. C. Wyant,et al.  Rough surface interferometry at 10.6 microm. , 1980, Applied optics.

[2]  Dong Liu,et al.  Study on testing larger asphericity in non-null interferometer , 2007, SPIE/COS Photonics Asia.

[3]  D Malacara,et al.  Design of lenses to project the image of a pupil in optical testing interferometers. , 1995, Applied optics.

[4]  Thomas Blümel,et al.  Interferometric asphere testing in a spherical test setup , 2005, SPIE Optical Systems Design.

[5]  Dong Liu,et al.  The wavefront aberration analysis and testing accuracy evaluation for the large aberration aspheric system based on the best fit sphere , 2007, SPIE/COS Photonics Asia.

[6]  Takanori Yazawa,et al.  Radial shearing interferometer for in-process measurement of diamond turning , 2000 .

[7]  John E Greivenkamp,et al.  Design of a nonnull interferometer for aspheric wave fronts. , 2004, Applied optics.

[8]  Neil Gardner,et al.  Retrace error evaluation on a figure-measuring interferometer , 2005, SPIE Optics + Photonics.

[9]  Dong Liu,et al.  Real time diagnosis of transient pulse laser with high repetition by radial shearing interferometer. , 2007, Applied optics.

[10]  Dong Liu,et al.  Measurement of transient near-infrared laser pulse wavefront with high precision by radial shearing interferometer , 2007 .

[11]  Abe Offner,et al.  A Null Corrector for Paraboloidal Mirrors , 1963 .

[12]  D T Moore,et al.  Interference imaging for aspheric surface testing. , 2000, Applied optics.

[13]  Feenix Y Pan,et al.  Efficient testing of segmented aspherical mirrors by use of a reference plate and computer-generated holograms. II. Case study, error analysis, and experimental validation. , 2004, Applied optics.

[14]  Dong Liu,et al.  System optimization of radial shearing interferometer for aspheric testing , 2007, SPIE/COS Photonics Asia.

[15]  John J. Sullivan,et al.  Design of partial nulls for testing of fast aspheric surfaces , 2007, SPIE Optical Engineering + Applications.

[16]  Joseph M. Geary,et al.  Retrace error: a case study , 1992, Optics & Photonics.