Resonance frequency of four-terminal-pair air-dielectric capacitance standards and closing the metrological impedance triangle

A new technique for determining the resonance frequency (f0) of four-terminal-pair air-dielectric capacitance standards is discussed. The resonance frequency is determined by measuring four parameters of the capacitance standards over a range of frequencies near f0. These parameters are the two-terminal-pair impedance coefficients as defined in an impedance matrix. From a knowledge of the four-terminal-pair resonance frequency of the standards it is possible to calculate their frequency dependence for f f0 using a simple electrical model. For air-dielectric capacitance standards it is also possible to determine their dissipation factor from the −3 dB width of the measured resonance curve. Ultimately, the validity of the technique described here would need to be verified by establishing closure of a proposed 'metrological impedance triangle' (MIT). This would involve measuring the frequency dependence of a four-terminal-pair air-dielectric capacitance and a calculable resistance standard in a 10:1 bridge between a range of frequencies, for example 1.592 kHz and 1.592 MHz. The same standards are then compared in a quadrature bridge operating at the upper frequency of 1.592 MHz to enable closure of the MIT. Accurate closure of the MIT would be an important test for the validity of a number of high-frequency techniques and calculations for the first time.

[1]  S. A. Awan,et al.  Evaluation of coaxial bridge systems for accurate determination of the SI Farad from the DC quantum Hall effect , 2003 .

[2]  Yicheng Wang Frequency dependence of capacitance standards , 2003 .

[3]  Luca Callegaro,et al.  Four-terminal-pair impedances and scattering parameters , 2003 .

[4]  M. Liess A description of properties and errors of simple and stacked sensors , 2003 .

[5]  Shakil A. Awan,et al.  A new four terminal-pair bridge for traceable impedance measurements at frequencies up to 1 MHz , 2001, IEEE Trans. Instrum. Meas..

[6]  B. P. Kibble,et al.  Controlling ac losses in quantum Hall effect devices , 2000 .

[7]  S. A. Awan,et al.  Calibration of IVDs at frequencies up to 1 MHz by permuting capacitors , 2000 .

[8]  K. Suzuki,et al.  A new universal calibration method for four-terminal-pair admittance standards , 1990, Conference on Precision Electromagnetic Measurements.

[9]  Raymond Nelson Jones,et al.  Evaluation of Three-Terminal and Four-Terminal Pair Capacitorsat High Frequencies | NIST , 1980 .

[10]  B. Inglis Frequency Dependence of Electrode Surface Effects in Parallel-Plate Capacitors , 1975, IEEE Transactions on Instrumentation and Measurement.

[11]  Wim De Waele,et al.  Optical measurement of target displacement and velocity in bird strike simulation experiments , 2003 .

[12]  G. H. Rayner,et al.  Coaxial Ac Bridges , 1984 .

[13]  R. D. Cutkosky Four-terminal-pair networks as precision admittance and impedance standards , 1964, IEEE Transactions on Communication and Electronics.