High-Tech Hip Implant for Wireless Temperature Measurements In Vivo

When walking long distances, hip prostheses heat up due to friction. The influence of articulating materials and lubricating properties of synovia on the final temperatures, as well as any potential biological consequences, are unknown. Such knowledge is essential for optimizing implant materials, identifying patients who are possibly at risk of implant loosening, and proving the concepts of current joint simulators. An instrumented hip implant with telemetric data transfer was developed to measure the implant temperatures in vivo. A clinical study with 100 patients is planned to measure the implant temperatures for different combinations of head and cup materials during walking. This study will answer the question of whether patients with synovia with poor lubricating properties may be at risk for thermally induced bone necrosis and subsequent implant failure. The study will also deliver the different friction properties of various implant materials and prove the significance of wear simulator tests. A clinically successful titanium hip endoprosthesis was modified to house the electronics inside its hollow neck. The electronics are powered by an external induction coil fixed around the joint. A temperature sensor inside the implant triggers a timer circuit, which produces an inductive pulse train with temperature-dependent intervals. This signal is detected by a giant magnetoresistive sensor fixed near the external energy coil. The implant temperature is measured with an accuracy of 0.1°C in a range between 20°C and 58°C and at a sampling rate of 2–10 Hz. This rate could be considerably increased for measuring other data, such as implant strain or vibration. The employed technique of transmitting data from inside of a closed titanium implant by low frequency magnetic pulses eliminates the need to use an electrical feedthrough and an antenna outside of the implant. It enables the design of mechanically safe and simple instrumented implants.

[1]  Paulo R Fernandes,et al.  Computational hip joint simulator for wear and heat generation. , 2007, Journal of biomechanics.

[2]  Ken Kumagai,et al.  Cellular strategies for enhancement of fracture repair. , 2008, The Journal of bone and joint surgery. American volume.

[3]  M Semlitsch,et al.  Metal-On-Metal Articulation for Artificial Hip Joints: Laboratory Study and Clinical Results , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[4]  D. Swann,et al.  The lubricating activity of human synovial fluids. , 1984, Arthritis and rheumatism.

[5]  Antonius Rohlmann,et al.  Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants , 2007, IEEE Transactions on Biomedical Engineering.

[6]  P S Walker,et al.  Telemetry of forces from proximal femoral replacements and relevance to fixation. , 1997, Journal of biomechanics.

[7]  S. Affatato,et al.  Thermomechanical analysis of ultra-high molecular weight polyethylene-metal hip prostheses , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  D. Resnick,et al.  Hip joint fluid: detection and distribution at MR imaging and US with cadaveric correlation. , 1998, Radiology.

[9]  M. Naruszewicz,et al.  Propionate reduces the cytokine-induced VCAM-1 and ICAM-1 expression by inhibiting nuclear factor-kappa B (NF-kappaB) activation. , 2009, Journal of physiology and pharmacology : an official journal of the Polish Physiological Society.

[10]  N Verdonschot,et al.  Frictional heating of total hip implants. Part 1: measurements in patients. , 2001, Journal of biomechanics.

[11]  G Bergmann,et al.  Four-channel telemetry system for in vivo measurement of hip joint forces. , 1991, Journal of biomedical engineering.

[12]  J. Crisco,et al.  Comparison of two methods for calculating the frictional properties of articular cartilage using a simple pendulum and intact mouse knee joints. , 2009, Journal of biomechanics.

[13]  G. Wiśniewska,et al.  Experimental research on the possibilities of maintaining thermal conditions within the limits of the physiological conditions during intraoral preparation of dental implants. , 2009, Journal of physiology and pharmacology : an official journal of the Polish Physiological Society.

[14]  V. Ribitsch,et al.  [Viscosity of synovial fluid and possible artificial lubricants (author's transl)]. , 1980, Acta medica Austriaca.

[15]  Christian Moss,et al.  Integration of a telemetric system within an intramedullary nail for monitoring of the fracture healing progress , 2010, 2010 3rd International Symposium on Applied Sciences in Biomedical and Communication Technologies (ISABEL 2010).

[16]  Kimimitsu Oda,et al.  Influence of heat stress to matrix on bone formation. , 2009, Clinical oral implants research.

[17]  Wolf-Joachim Fischer,et al.  Integration of a wireless lock-in measurement of hip prosthesis vibrations for loosening detection , 2009 .

[18]  Zhongmin Jin,et al.  Friction of total hip replacements with different bearings and loading conditions. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.

[19]  J. Kärrholm The Swedish Hip Arthroplasty Register (www.shpr.se) , 2010, Acta orthopaedica.

[20]  H. Chikama [The role of protein and hyaluronic acid in the synovial fluid in animal joint lubrication]. , 1985, Nihon Seikeigeka Gakkai zasshi.

[21]  A H Burstein,et al.  Telemetering in vivo loads from nail plate implants. , 1982, Journal of biomechanics.

[22]  A. Moritz,et al.  Studies of Thermal Injury: II. The Relative Importance of Time and Surface Temperature in the Causation of Cutaneous Burns. , 1947, The American journal of pathology.

[23]  H. Mckellop,et al.  Effect of protein lubrication on the wear properties of materials for prosthetic joints. , 1999, Journal of biomedical materials research.

[24]  H. Mckellop,et al.  Frictional heating of bearing materials tested in a hip joint wear simulator , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[25]  E Schneider,et al.  Loads acting in an intramedullary nail during fracture healing in the human femur. , 2001, Journal of biomechanics.

[26]  J. Bryant,et al.  Rheological properties of synovial fluids. , 2007, Biorheology.

[27]  N Verdonschot,et al.  Frictional heating of total hip implants. Part 2: finite element study. , 2001, Journal of biomechanics.

[28]  J. Pritchett Heat Generated by Knee Prostheses , 2006, Clinical orthopaedics and related research.

[29]  A Rohlmann,et al.  Hip endoprosthesis for in vivo measurement of joint force and temperature. , 1999, Journal of biomechanics.

[30]  Robertw . Mann,et al.  Experimental temperature rise in human hip joint in vitro in simulated walking , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[31]  A Unsworth,et al.  A five-station hip joint simulator , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[32]  A Rohlmann,et al.  Multichannel strain gauge telemetry for orthopaedic implants. , 1988, Journal of biomechanics.

[33]  P. Branemark,et al.  Heat shock-induced necrosis and apoptosis in osteoblasts. , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[34]  S. Asbell,et al.  Effects of hyperthermia on bone. II. Heating of bone in vivo and stimulation of bone growth. , 1993, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[35]  Shu Chien,et al.  Heat shock‐induced necrosis and apoptosis in osteoblasts , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[36]  Zhongmin Jin,et al.  Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position. , 2008, The Journal of bone and joint surgery. American volume.

[37]  Robert Puers,et al.  A telemetry system for the detection of hip prosthesis loosening by vibration analysis , 2000 .