Optimization of eddy-current compensation☆

Abstract A comprehensive method for optimizing the preemphasis applied to pulsed gradients in NMR experiments in order to compensate induced eddy-current fields is presented. First, the eddy-current effects are measured without any compensation active. The eddy-current fields with spatial symmetries different from those of the pulsed gradient are also taken into account. Next, the measured response functions are analyzed with exponentially decaying terms. An exact solution of the required compensation is provided by numerical inversion of the response function using Laplace transformation. The calculated compensation terms are implemented in hardware. This yields a highly improved suppression of the eddy-current effects, including induced fields with spatial symmetries different from those of the switched gradient. The result is independent of the waveform or timing of the pulsed gradient and can compete with shielded gradient systems.

[1]  A finite element/Fourier expansion technique for the design of a pulsed radial gradient system for magnetic resonance imaging (MRI) , 1985 .

[2]  H C Charles,et al.  Human in vivo phosphate metabolite imaging with 31P NMR , 1988, Magnetic resonance in medicine.

[3]  S. Dønstrup,et al.  Magnetic field shimming by fourier analysis , 1988, Magnetic resonance in medicine.

[4]  R. Ordidge,et al.  Snap-shot magnetic resonance imaging at 0.1 T using double-screened gradients , 1988 .

[5]  G. Morrow,et al.  Superconducting magnets for magnetic resonance imaging applications , 1987 .

[6]  L. B. Nesbitt,et al.  Eddy‐Current Method for Measuring the Resistivity of Metals , 1959 .

[7]  P. Jehenson,et al.  Correction of distortions due to the pulsed magnetic field gradient‐induced shift in B0 field by postprocessing , 1989, Magnetic resonance in medicine.

[8]  D. Lindholm,et al.  Analysis of Resistivity Measurements by the Eddy Current Decay Method , 1968 .

[9]  W. Dannels,et al.  Exact temporal eddy current compensation in magnetic resonance imaging systems. , 1988, IEEE transactions on medical imaging.

[10]  P. Mansfield,et al.  Active magnetic screening of coils for static and time-dependent magnetic field generation in NMR imaging , 1986 .

[11]  Ronald N. Bracewell,et al.  The Fourier Transform and Its Applications , 1966 .

[12]  Society of magnetic resonance in medicine , 1990 .

[13]  R. L. Stoll The analysis of eddy currents , 1974 .

[14]  D. Doddrell,et al.  Water suppression with B0 field gradient homospoil pulses in high‐resolution NMR spectroscopy , 1989, Magnetic resonance in medicine.

[15]  R Turner,et al.  Real‐time movie imaging from a single cardiac cycle by NMR , 1987, Magnetic resonance in medicine.

[16]  G. Temple Static and Dynamic Electricity , 1940, Nature.

[17]  D. Hoult,et al.  Magnet field profiling: Analysis and correcting coil design , 1984, Magnetic resonance in medicine.

[18]  H. Buckmaster,et al.  The determination of absolute and relative B gradients using rapid-scan NMR. AL computational modeling evaluation , 1988 .

[19]  Roger J. Ordidge,et al.  THE CORRECTION OF TRANSIENT B0 FIELD SHIFTS FOLLOWING THE APPLICATION OF PULSED GRADIENTS BY PHASE CORRECTION IN THE TIME DOMAIN , 1986 .

[20]  P A Narayana,et al.  Reduction of pulsed gradient settling time in the superconducting magnet of a magnetic resonance instrument. , 1987, Medical physics.

[21]  P. V. van Zijl,et al.  High field localized proton spectroscopy in small volumes: greatly improved localization and shimming using shielded strong gradients , 1989, Magnetic resonance in medicine.

[22]  R Turner,et al.  Snapshot imaging at 0.5 t using echo‐planar techniques , 1989, Magnetic resonance in medicine.

[23]  R. Turner,et al.  Passive screening of switched magnetic field gradients , 1986 .

[24]  Paul Mansfield,et al.  LETTER TO THE EDITOR: Double active magnetic screening of coils in NMR , 1986 .

[25]  的崎 健 Society of Magnetic Resonance in Medicine の Second Annual Meeting への参加報告:とくにイメージングを中心として , 1983 .

[26]  J. Huisman The Netherlands , 1996, The Lancet.