Low-temperature plasma sterilization has been experimentally demonstrated using surface-wave plasma excited by a 2.45 GHz microwave. With the spores of Bacillus stearothermophilus and Bacillus subtilis as biological indicators, we have carried out the plasma sterilization experiments by varying the irradiation period of oxygen plasma discharges. It was experimentally confirmed that the spores with a population of 1.5 ×106 were sterilized by irradiating them with oxygen plasma discharges generated with a microwave power of 700 W at a pressure of 60–80 mTorr for 3 min or longer. From the scanning electron microscopy (SEM) analysis of the spores, we found that the sterilized spores clearly had different sizes and shapes compared with those before the plasma irradiation. Furthermore, present experiments suggested that the changes of spore shapes were mainly attributed to the reactive interactions with oxygen radicals.
[1]
L. Yahia,et al.
Effect of gas composition on spore mortality and etching during low-pressure plasma sterilization.
,
2000,
Journal of biomedical materials research.
[2]
S. Block,et al.
Disinfection, sterilization, and preservation
,
1977
.
[3]
M. Nagatsu,et al.
Characteristics of Ultrahigh-Frequency Surface-Wave Plasmas Excited at 915 MHz
,
1999
.
[4]
M. Nagatsu,et al.
Mode identification of surface waves excited in a planar microwave discharge
,
1997
.
[5]
M. Nagatsu,et al.
Optical Emission and Microwave Field Intensity Measurements in Surface Wave-Excited Planar Plasma
,
1996
.