Development of a 3D Semi-Automatic Measurement Protocol for Hand Anthropometric Measurement

Measurement protocols for hand anthropometry have been studied for ergonomic product design. The present study developed a 3D semi-automatic measurement protocol (3D-SAMP) which semi-automatically measures various hand dimensions using a 3D scanner. The 3D-SAMP was compared with the conventional direct measurement method (DMM) to examine its effectiveness. The 3D-SAMP consists of (1) fabricating a plaster cast of the hand, (2) placing landmarks on the plaster hand, (3) scanning the plaster hand with a 3D scanner, (4) identifying automatically the positions of the landmarks on the digital hand, and (5) extracting automatically hand anthropometric measurements (lengths, widths, thicknesses, and circumferences). An evaluation experiment conducted in the study found the 3D-SAMP preferred to the DMM in terms of reliability (the number of dimensions exceeding the variability criteria SD

[1]  Hye Seon Choe,et al.  The Database Development of 2-D Hands Measurement for Improving Fitness of gloves - focused on the ages from 18 to 64 of male & female adults - , 2004 .

[2]  Kwon Myoungsook,et al.  A Study on Establishment of Glove Size System and Hand Shape , 2005 .

[3]  John W. Garrett,et al.  ANTHROPOMETRY OF THE HANDS OF MALE AIR FORCE FLIGHT PERSONNEL , 1970 .

[4]  Ozgur Tosun,et al.  Method selection in craniofacial measurements: advantages and disadvantages of 3D digitization method. , 2009, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[5]  김진호,et al.  영상처리를 이용한 인체 간접 측정기술 개발연구 ( A Study on The Non-Contact Body Measurements Using Image Processing ) , 1989 .

[6]  David Hidson Development of a Standard Anthropometric Dimension set for Use in Computer-Aided Glove Design , 1991 .

[7]  Nicole M. Scott,et al.  Intraobserver error associated with measurements of the hand , 2005, American journal of human biology : the official journal of the Human Biology Council.

[8]  Yun-Ja Nam,et al.  Development of Three Dimensional Scanner for Anthropometric Measurement , 2001 .

[9]  Kathleen M Robinette,et al.  A Nine-Size System for Chemical Defense Gloves , 1986 .

[10]  Ji-Young Lim Classification of Hand Types for the Development of Glove Patterns , 2005 .

[11]  Alfons Juan-Císcar,et al.  The MORFO3D Foot Database , 2005, IbPRIA.

[12]  Zhizhong Li,et al.  Validation of a three-dimensional hand scanning and dimension extraction method with dimension data , 2008, Ergonomics.

[13]  Zhizhong Li,et al.  Error control and calibration in three-dimensional anthropometric measurement of the hand by laser scanning with glass support , 2007 .