Vibration Analysis and Models of Adjacent Structures Controlled by Magnetorheological Dampers

This paper deals with the vibration analysis of adjacent structures controlled by a magnetorheological (MR) damper and with the discussion of a numerical procedure for identification and definition of a reliable finite element model. The paper describes an extensive experimental campaign investigating the dynamic response, through shaking table tests, of a tridimensional four-story structure and a two-story structure connected by an MR device. Several base excitations and intensity levels are considered. The structures were tested in nonconnected and connected configuration, with the MR damper operating in passive or semiactive mode. Moreover, the paper illustrates a procedure for the structural identification and the definition of a reliable numerical model valid for adjacent structures connected by MR dampers. The procedure is applied in the original nonconnected configuration, which represents a linear system, and then in the connected configuration, which represents a nonlinear system due to the MR damper. In the end, the updated finite element model is reliable and suitable for all the considered configurations and the mass, damping, and stiffness matrices are derived. The experimental and numerical responses are compared and the results confirm the effectiveness of the identification procedure and the validation of the finite element model.

[1]  M. De Angelis,et al.  A reduced order model for optimal design of 2-mdof adjacent structures connected by hysteretic dampers , 2007 .

[2]  Danilo Capecchi,et al.  Modal model identification of structures under unmeasured seismic excitations , 2005 .

[3]  R. S. Pappa,et al.  A comparative overview of modal testing and system identification for control of structures , 1988 .

[4]  P. G. Bakir,et al.  Sensitivity-based finite element model updating using constrained optimization with a trust region algorithm , 2007 .

[5]  W. Marsden I and J , 2012 .

[6]  Kevin Barraclough,et al.  I and i , 2001, BMJ : British Medical Journal.

[7]  Minh Q. Phan,et al.  Identification and Control of Mechanical Systems: Frontmatter , 2001 .

[8]  T. T. Soong,et al.  STRUCTURAL CONTROL: PAST, PRESENT, AND FUTURE , 1997 .

[9]  Danilo Capecchi,et al.  Modal Model Identification with Unknown Nonstationary Base Motion , 2004 .

[10]  Richard W. Longman,et al.  Identification of linear structural systems using earthquake‐induced vibration data , 1999 .

[11]  Kazuto Seto,et al.  Coupled Building Control Using Acceleration Feedback , 2003 .

[12]  Farhan Gandhi,et al.  Magnetorheological fluid damper feedback linearization control for helicopter rotor application , 2001 .

[13]  Ian F. C. Smith,et al.  System Identification through Model Composition and Stochastic Search , 2005 .

[14]  M. De Angelis,et al.  Shaking table experimentation on adjacent structures controlled by passive and semi-active MR dampers , 2013 .

[15]  Hengjia Zhu,et al.  Optimum connecting dampers to reduce the seismic responses of parallel structures , 2011 .

[16]  Maura Imbimbo,et al.  A Procedure to Identify the Modal and Physical Parameters of a Classically Damped System under Seismic Motions , 2012 .

[17]  Shirley J. Dyke,et al.  PHENOMENOLOGICAL MODEL FOR MAGNETORHEOLOGICAL DAMPERS , 1997 .

[18]  Hamid Reza Karimi,et al.  Semiactive-passive structural vibration control strategy for adjacent structures under seismic excitation , 2012, J. Frankl. Inst..

[19]  Nicholas D. Oliveto,et al.  Time domain identification of hybrid base isolation systems using free vibration tests , 2010 .

[20]  Minh Q. Phan,et al.  Identification and control of mechanical systems , 2001 .

[21]  Kung-Chun Lu,et al.  System identification of mid‐story isolation building using both ambient and earthquake response data , 2013 .

[22]  Yl L. Xu,et al.  Semiactive Seismic Response Control of Buildings with Podium Structure , 2005 .

[23]  Mohammad Noori,et al.  System Identification of Base-Isolated Building using Seismic Response Data , 2005 .

[24]  Yi-Qing Ni,et al.  State‐Derivative Feedback Control of Cable Vibration Using Semiactive Magnetorheological Dampers , 2005 .

[25]  J. David Carlson,et al.  Smart prosthetics based on magnetorheological fluids , 2001, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[26]  Yl L. Xu,et al.  Experimental Seismic Study of Adjacent Buildings with Fluid Dampers , 2003 .

[27]  M. De Angelis,et al.  Optimal passive control of adjacent structures interconnected with nonlinear hysteretic devices , 2007 .

[28]  R. Stephenson A and V , 1962, The British journal of ophthalmology.

[29]  S. M. Dumne,et al.  Seismic response analysis of adjacent buildings connected with MR dampers , 2010 .

[30]  莊哲男 Applied System Identification , 1994 .

[31]  Kazuto Seto,et al.  Optimal Design Strategy of Connected Control Method for Two Dynamically Similar Structures , 2007 .

[32]  R. S. Jangid,et al.  Seismic analysis of structures connected with friction dampers , 2006 .

[33]  Yi-Qing Ni,et al.  RANDOM SEISMIC RESPONSE ANALYSIS OF ADJACENT BUILDINGS COUPLED WITH NON-LINEAR HYSTERETIC DAMPERS , 2001 .

[34]  John E. Mottershead,et al.  Finite Element Model Updating in Structural Dynamics , 1995 .

[35]  Jm M. Ko,et al.  Experimental investigation of adjacent buildings connected by fluid damper , 1999 .

[36]  Erik A. Johnson,et al.  Semiactive Connected Control Method for Adjacent Multidegree-of-Freedom Buildings , 2007 .