Quantum-limited FM-spectroscopy with a lead-salt diode laser

Ultrasensitive absorption spectroscopy of NO2 was performed with a tunable lead-salt diode laser (TDL) using a single-tone high-frequency modulation (FM) technique. With a detection bandwidth of 200 kHz, an optical density of 2.7 × 10−5 was detectable at SNR of 1. The detectable optical density could be further improved by reducing the detection bandwidth in agreement with the √Δf relationship, reaching 2.5 × 10−6 at a detection bandwidth of 1.56 kHz. Normalized to 1 Hz bandwidth, the demonstrated performance would then correspond to a detectable optical density of 5.9 × 10−8. This detection limit agrees well with the calculated “quantum limited” performance based on the measured laser power, modulation index, noise figure of the electronic components, and other parameters of the apparatus. These measurements and calculations show that by implementation of the FM technique, the sensitivity of the present TDL absorption spectrometers (TDLAS) can be improved by at least a factor of 10 and possibly even of 100. Such a sensitivity improvement would greatly extend the applicability of TDLAS for trace gas analysis, especially in atmospheric monitoring.

[1]  G. Sachse,et al.  Single-tone and two-tone AM-FM spectral calculations for tunable diode laser absorption spectroscopy. , 1987, Applied optics.

[2]  W Lenth,et al.  High-frequency-modulation spectroscopy with a lead-salt diode laser. , 1986, Optics letters.

[3]  G I Mackay,et al.  Tunable diode laser systems for measuring trace gases intropospheric air. , 1983, Environmental science & technology.

[4]  G. Bjorklund,et al.  Frequency-modulation spectroscopy: a new method for measuring weak absorptions and dispersions. , 1980, Optics letters.

[5]  M. Osiński,et al.  Linewidth broadening factor in semiconductor lasers--An overview , 1987 .

[6]  B. Hicks,et al.  Critique of methods to measure dry deposition workshop summary , 1980 .

[7]  W. Lenth,et al.  High frequency heterodyne spectroscopy with current-modulated diode lasers , 1984 .

[8]  B K Garside,et al.  Sensitivity limits of a tunable diode laser spectrometer, with application to the detection of NO(2) at the 100-ppt level. , 1980, Applied optics.

[9]  Glen W. Sachse,et al.  Fast‐response, high‐precision carbon monoxide sensor using a tunable diode laser absorption technique , 1987 .

[10]  W. Lenth,et al.  Sensitive detection of NO2 using high‐frequency heterodyne spectroscopy with a GaAlAs diode laser , 1985 .

[11]  J. A. Silver,et al.  Airborne measurements of humidity using a single-mode Pb-salt diode laser. , 1987, Applied optics.

[12]  J. A. Silver,et al.  Two-tone optical heterodyne spectroscopy using buried double heterostructure lead-salt diode lasers. , 1988, Applied optics.

[13]  J. Reid,et al.  High-sensitivity detection of trace gases using sweep integration and tunable diode lasers. , 1982, Applied optics.

[14]  D E Cooper,et al.  Frequency modulation spectroscopy with lead-salt diode lasers: a comparison of single-tone and two-tone techniques. , 1987, Applied optics.

[15]  H. Preier,et al.  Monitoring of gaseous pollutants by tunable diode lasers , 1987 .

[16]  W. Lenth,et al.  Optical heterodyne spectroscopy with frequency- and amplitude-modulated semiconductor lasers. , 1983, Optics letters.

[17]  Christopher R. Webster,et al.  Brewster-plate spoiler: a novel method for reducing the amplitude of interference fringes that limit tunable-laser absorption sensitivities , 1985 .

[18]  Yoshihisa Yamamoto,et al.  Direct frequency modulation in AlGaAs semiconductor lasers , 1982 .

[19]  C. Carlisle,et al.  High-sensitivity FM spectroscopy with a lead-salt diode laser. , 1988, Optics letters.