Critical Short Circuit Ratio Analysis on DFIG Wind Farm with Vector Power Control and Synchronized Control

The introduction of renewable energy sources into the AC grid can change and weaken the strength of the grid, which will in turn affect the stability and robustness of the doubly-fed induction generator (DFIG) wind farm. When integrated with weak grids, the DFIG wind turbine with vector power control often suffers from poor performance and robustness, while the DFIG wind turbine with synchronized control provides better stability. This paper investigates the critical short circuit ratios of DFIG wind turbine with vector power control and synchronized control, to analyze the stability boundary of the DFIG wind turbine. Frequency domain methods based on sensitivity and complementary sensitivity of transfer matrix are used to investigate the stability boundary conditions. The critical capacity of DFIG wind farm with conventional vector power control at a certain point of common coupling (PCC) is obtained and is further increased by employing synchronized control properly. The stability boundary is validated by electromagnetic transient simulation of an offshore wind farm connected to a real regional grid.

[1]  K.. De Brabandere,et al.  A Voltage and Frequency Droop Control Method for Parallel Inverters , 2007, IEEE Transactions on Power Electronics.

[2]  Ian Postlethwaite,et al.  Multivariable Feedback Control: Analysis and Design , 1996 .

[3]  Boon-Teck Ooi,et al.  Magnitude and frequency control of grid-connected doubly fed induction generator based on synchronised model for wind power generation , 2010 .

[4]  Dong Wang,et al.  Stability of DC-link voltage affected by phase-locked loop for DFIG-based wind turbine connected to a weak AC system , 2014, 2014 17th International Conference on Electrical Machines and Systems (ICEMS).

[5]  Xiao Yong,et al.  The problems and solutions for large-scale concentrated integration of wind power to partially weak regional power grid , 2009, 2009 International Conference on Sustainable Power Generation and Supply.

[6]  Innocent Kamwa,et al.  Robust design and coordination of multiple damping controllers using nonlinear constrained optimization , 1999 .

[7]  Jihun Kim,et al.  Hybrid Secondary Voltage Control combined with Large-Scale Wind Farms and Synchronous Generators , 2014 .

[8]  Dragan Jovcic,et al.  Stability of a Variable-Speed Permanent Magnet Wind Generator With Weak AC Grids , 2010, IEEE Transactions on Power Delivery.

[9]  Jul-Ki Seok,et al.  Hierarchical Voltage Control of a Wind Power Plant Using the Adaptive IQ-V Characteristic of a Doubly-Fed Induction Generator , 2015 .

[10]  Amin Hajizadeh,et al.  Effect of distribution system specifications on voltage stability in presence of wind distributed generation , 2011, 16th Electrical Power Distribution Conference.

[11]  Dong Peng,et al.  The impact of LVRT characteristic on the stability of Northwest China grid with large scale wind power , 2013 .

[12]  Hao Yuan,et al.  Synchronizing stability of DFIG-based wind turbines attached to weak AC grid , 2014, 2014 17th International Conference on Electrical Machines and Systems (ICEMS).

[13]  L. Y. Chen,et al.  The comparison of common control strategies in grid-connected double-fed wind generators , 2013, 2013 IEEE International Conference of IEEE Region 10 (TENCON 2013).

[14]  Roberto Cárdenas,et al.  Overview of control systems for the operation of DFIGs in wind energy applications , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[15]  Li Wang,et al.  Analysis of voltage variations and short-circuit ratios of a large-scale offshore wind farm connected to a practical power system , 2013, 2013 IEEE Power & Energy Society General Meeting.

[16]  I. Erlich,et al.  Response of DFG-based wind farms operating on weak grids to voltage sags , 2011, 2011 IEEE Power and Energy Society General Meeting.

[17]  Zehan LU,et al.  Small signal stability analysis of a synchronized control-based microgrid under multiple operating conditions , 2014 .

[18]  Liangzhong Yao,et al.  Novel Integration of DFIG-Based Wind Generators Within Microgrids , 2011, IEEE Transactions on Energy Conversion.

[19]  Rajiv K. Varma,et al.  SSR in Double-Cage Induction Generator-Based Wind Farm Connected to Series-Compensated Transmission Line , 2013, IEEE Transactions on Power Systems.

[20]  Lie Xu,et al.  VSC transmission model for analytical studies , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[21]  Lidong Zhang Modeling and Control of VSC-HVDC Links Connected to Weak AC Systems , 2010 .