Investigation of the effect of rollbond evaporator design on the performance of direct expansion heat pump experimentally

Abstract In this study, the rollbond evaporator design which gives maximum coefficient of performance for the direct expansion solar assisted heat pump (DX-SAHP) water heater is investigated experimentally on the three separate heat pump systems due to the lack of studies on the effect of collector-evaporator design to the system performance. Three DX-SAHP systems are identical except collector-evaporator design. Aluminum is preferred for the evaporator material and R134a as the working fluid. Maximum COP value was obtained as 3.30 for System-1 while COP values for System-2 and System-3 were 3.14 and 2.42 respectively at the same conditions. An empirical correlation which gives the COP value of the System-1, which provides highest COP, with respect to the solar radiation and outdoor temperature of the system has been found using the experimental results obtained during the study. The correlation was found to be in good agreement with the average deviation of 9% with the experimental data.

[1]  Bin-Juine Huang,et al.  Performance analysis of a solar-assisted heat pump water heater , 2003 .

[2]  Mohammad Nurul Alam Hawlader,et al.  The performance of a solar assisted heat pump water heating system , 2001 .

[3]  Ruzhu Wang,et al.  Experimental performance analysis on a direct-expansion solar-assisted heat pump water heater , 2007 .

[4]  Ruzhu Wang,et al.  Experimental performance analysis and optimization of a direct expansion solar-assisted heat pump water heater , 2007 .

[5]  Sushil K. Chaturvedi,et al.  Analysis of a direct expansion solar assisted heat pump using different refrigerants , 2005 .

[6]  Mohammad Nurul Alam Hawlader,et al.  Performance of evaporator-collector and air collector in solar assisted heat pump dryer , 2008 .

[7]  Bin-Juine Huang,et al.  Long-term performance of solar-assisted heat pump water heater , 2004 .

[8]  K. F. Fong,et al.  Modeling and application of direct-expansion solar-assisted heat pump for water heating in subtropical Hong Kong , 2010 .

[9]  Bin-Juine Huang,et al.  Performance evaluation method of solar-assisted heat pump water heater , 2007 .

[10]  Bin-Juine Huang,et al.  Performance characteristics of integral type solar-assisted heat pump , 2001 .

[11]  J. Enaburekhan,et al.  Performance evaluation of a refrigerant-charged integrated solar water heater in northern Nigeria , 2009 .

[12]  Bin-Juine Huang,et al.  Integral-type solar-assisted heat pump water heater , 1999 .

[13]  S. Ito,et al.  PERFORMANCE OF A HEAT PUMP USING DIRECT EXPANSION SOLAR COLLECTORS 1 Paper presented at the ISES Sol , 1999 .