A New Noninvasive System for Clinical Pulse Wave Velocity Assessment: The Athos Device

This paper presents a low cost, noninvasive, clinical-grade Pulse Wave Velocity evaluation device. The proposed system relies on a simultaneous acquisition of femoral and carotid pulse waves to improve estimation accuracy and correctness. The sensors used are two high precision MEMS force sensors, encapsulated in two ergonomic probes, and connected to the main unit. Data are then wirelessly transmitted to a standard laptop, where a dedicated graphical user interface (GUI) runs for analysis and recording. Besides the interface, the Athos system provides a Matlab algorithm to process the signals quickly and achieve a reliable PWV assessment. To better compare the results at the end of each analysis, a detailed report is generated, including all the relevant examination information (subject data, mean PTT, and obtained PWV). A pre-clinical study was conducted to validate the system by realizing several Pulse Wave Velocity measurements on ten heterogeneous healthy subjects of different ages. The collected results were then compared with those measured by a well-established and largely more expensive clinical device (SphygmoCor).

[1]  J. Cohn,et al.  Noninvasive pulse wave analysis for the early detection of vascular disease. , 1995, Hypertension.

[2]  Vasiliki Bikia,et al.  Noninvasive Cardiac Output and Central Systolic Pressure From Cuff-Pressure and Pulse Wave Velocity , 2019, IEEE Journal of Biomedical and Health Informatics.

[3]  J. Gallacher,et al.  An Analysis of Prospective Risk Factors for Aortic Stiffness in Men: 20-Year Follow-Up From the Caerphilly Prospective Study , 2010, Hypertension.

[4]  F. Veglio,et al.  Current assessment of pulse wave velocity: comprehensive review of validation studies. , 2019, Journal of hypertension.

[5]  J. Carroll,et al.  Determination of pulse wave velocities with computerized algorithms. , 1991, American heart journal.

[6]  R. Townsend,et al.  Large-Artery Stiffness in Health and Disease: JACC State-of-the-Art Review. , 2019, Journal of the American College of Cardiology.

[7]  J. Filipovský,et al.  Expert consensus document on the measurement of aortic stiffness in daily practice using carotid-femoral pulse wave velocity. , 2012, Journal of hypertension.

[8]  Bradley S. Fleenor,et al.  Arterial Stiffness , 2019, SpringerBriefs in Physiology.

[9]  S. Millasseau,et al.  Comparison of the Complior Analyse device with Sphygmocor and Complior SP for pulse wave velocity and central pressure assessment , 2014, Journal of hypertension.

[10]  Mohanasankar Sivaprakasam,et al.  Arterial Blood Pressure Estimation From Local Pulse Wave Velocity Using Dual-Element Photoplethysmograph Probe , 2018, IEEE Transactions on Instrumentation and Measurement.

[11]  Francesco Rundo,et al.  Live Demonstration of Portable Systems based on Silicon Sensors for the monitoring of Physiological Parameters of Driver Drowsiness and Pulse Wave Velocity , 2018, 2018 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[12]  Thomas Kahan,et al.  2018 ESC/ESH Guidelines for the management of arterial hypertension. , 2018, European heart journal.

[13]  M. Butlin,et al.  Large Artery Stiffness Assessment Using SphygmoCor Technology , 2016, Pulse.

[14]  P. M. Nabeel,et al.  Local Pulse Wave Velocity: Theory, Methods, Advancements, and Clinical Applications , 2020, IEEE Reviews in Biomedical Engineering.

[15]  Ettore Ambrosioni,et al.  ESH/ESC guidelines for the management of arterial hypertension: how to implement in daily clinical practice , 2004 .

[16]  Paolo Salvi,et al.  Validation of a new non-invasive portable tonometer for determining arterial pressure wave and pulse wave velocity: the PulsePen device , 2004, Journal of hypertension.

[17]  E. Achten,et al.  Carotid to femoral pulse wave velocity: a comparison of real travelled aortic path lengths determined by MRI and superficial measurements , 2011, Journal of hypertension.

[18]  H. Struijker‐Boudier,et al.  Current Perspectives on Arterial Stiffness and Pulse Pressure in Hypertension and Cardiovascular Diseases , 2003, Circulation.

[19]  L. Wurfel Mcdonald S Blood Flow In Arteries Theoretical Experimental And Clinical Principles , 2016 .

[20]  Jennifer Taylor,et al.  2013 ESH/ESC guidelines for the management of arterial hypertension. , 2013, European heart journal.

[21]  C. Hayward,et al.  Noninvasive determination of age-related changes in the human arterial pulse. , 1989, Circulation.

[22]  N. Ranganathan,et al.  The Art and Science of Cardiac Physical Examination: With Heart Sounds and Pulse Wave Forms on CD , 2006 .

[23]  S. R. Rao,et al.  Assessment of Carotid Arterial Stiffness in Community Settings With ARTSENS® , 2021, IEEE Journal of Translational Engineering in Health and Medicine.

[24]  Carlos Correia,et al.  Novel Methods for Pulse Wave Velocity Measurement , 2015, Journal of Medical and Biological Engineering.

[25]  Siegfried Wassertheurer,et al.  Noninvasive determination of carotid–femoral pulse wave velocity depends critically on assessment of travel distance: a comparison with invasive measurement , 2009, Journal of hypertension.

[26]  J. Pipe,et al.  Direct magnetic resonance determination of aortic distensibility in essential hypertension: relation to age, abdominal visceral fat, and in situ intracellular free magnesium. , 1996, Hypertension.

[27]  Olivier Chételat,et al.  Chest Pulse-Wave Velocity: A Novel Approach to Assess Arterial Stiffness , 2011, IEEE Transactions on Biomedical Engineering.

[28]  P. Segers,et al.  Brief Review on How to Measure Arterial Stiffness in Humans. , 2019, Arteriosclerosis, thrombosis, and vascular biology.

[29]  Thomas M Grist,et al.  Review of MRI-based measurements of pulse wave velocity: a biomarker of arterial stiffness. , 2014, Cardiovascular diagnosis and therapy.