Reliability Assessment of Protective Relays in Harmonic-Polluted Power Systems

Proliferation of distributed generations (DGs) and power-electronics-based loads is bringing about more harmonic-polluted power signals. While some failures may occur as a consequence of nonsinusoidal current or voltage waveforms, existing reliability models of protection relays have not taken the harmonic-related failures into consideration. This paper develops a comprehensive Markov reliability model to categorize the possible functional states of a component, say a transmission line, protected by a relay, operating in a harmonic-polluted environment. In order to make the proposed model practically tractable, it is further simplified in two ways, through merging the states of the same consequence. The first simplified model focuses on the power component reliability assessment; while the other is built for reliability analysis of a protection system. Calculation of transition rates and how the resultant model is mathematically evaluated are then discussed. Numerical analyses and outcomes are based on the real-world data taken from Canadian substations. Accordingly, the results and conclusions drawn in this paper would be interesting to both academia and industry. Moreover, the proposed reliability assessment methodology is readily applicable in scrutinizing the impacts of harmonic pollution on the protection devices of other power components.

[1]  George J. Anders,et al.  A new look at component maintenance practices and their effect on customer, station and system reliability , 2006 .

[2]  C. Singh,et al.  Protection System Reliability Modeling: Unreadiness Probability and Mean Duration of Undetected Faults , 1980, IEEE Transactions on Reliability.

[3]  A. Al-Shaalan Reliability Evaluation of Power Systems , 2019, Reliability and Maintenance - An Overview of Cases.

[4]  Saul Goldberg,et al.  The Effect of Harmonics on the Operating Points of Electromechanical Relays , 1985, IEEE Power Engineering Review.

[5]  C. Singh,et al.  A practical approach for integrated power system vulnerability analysis with protection failures , 2004, IEEE Transactions on Power Systems.

[6]  P. M. Anderson,et al.  An improved reliability model for redundant protective systems-Markov models , 1997 .

[7]  H. Seyedi,et al.  An extended Markov model to determine the reliability of protective system , 2006, 2006 IEEE Power India Conference.

[8]  C. Borges,et al.  Probabilistic Wind Farms Generation Model for Reliability Studies applied to Brazilian Sites , 2007, 2007 IEEE Power Engineering Society General Meeting.

[9]  Kai Jiang,et al.  New Models and Concepts for Power System Reliability Evaluation Including Protection System Failures , 2011, IEEE Transactions on Power Systems.

[10]  A.A. Girgis,et al.  Effect of voltage harmonics on the operation of solid state relays in industrial applications , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[11]  M Fotuhi-Firuzabad,et al.  New Considerations in Modern Protection System Quantitative Reliability Assessment , 2010, IEEE Transactions on Power Delivery.

[12]  R. Billinton,et al.  Determination of the Optimum Routine Test and Self-Checking Intervals in Protective Relaying Using a Reliability Model , 2002, IEEE Power Engineering Review.

[13]  J. Sadeh,et al.  Considering failure probability for back-up relay in determination of the optimum routine test interval in protective system using Markov model , 2009, 2009 IEEE Power & Energy Society General Meeting.

[14]  M.A.S. Masoum,et al.  Impact of harmonics on tripping time of overcurrent relays , 2007, 2007 Australasian Universities Power Engineering Conference.

[15]  S.E. Zocholl,et al.  Effect of waveform distortion on protective relays , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[16]  Wang Gang,et al.  Reliability analysis of digital relay , 2004 .

[17]  Juliane Freud,et al.  Reliability Evaluation Of Engineering Systems , 2016 .