The development of mini pentameric STR loci for rapid analysis of forensic DNA samples on a microfluidic system

There is increasing interest in developing methods for portable DNA analysis in mass disasters and criminal identification. Currently most forensic STR DNA analysis is performed by CE; however, these instruments are not portable and require long sample run times. One potential solution is the development of microfluidic systems for DNA typing. Unfortunately, fairly long (ca. 20 cm) separation channels are usually required for the proper resolution of multiplexed STR loci used in human identification. Commercially available systems like the Agilent 2100 Bioanalyzer have a small footprint and utilize chips with shorter channels and reduced resolution. Such portable systems might be valuable for evidence screening in remote locations. However, due to their lower resolution, most standard 4 base STR loci and their inherent 2 base variants will not resolve on such systems. In this paper, we discuss the development of reduced length pentameric (5 base) STR amplicons. Pentameric STRs have fewer variant alleles and are easier to separate due to the wider spacing between alleles. By incorporating novel denaturing sieving polymers in a short microfluidic channel, we demonstrate efficient separations on these chips. Such an approach can serve as a useful tool for rapid microfluidic DNA typing.

[1]  Peng Liu,et al.  Integrated portable polymerase chain reaction-capillary electrophoresis microsystem for rapid forensic short tandem repeat typing. , 2007, Analytical chemistry.

[2]  Robert Burger,et al.  High‐speed analysis of multiplexed short tandem repeats with an electrophoretic microdevice , 2002, Electrophoresis.

[3]  A. Woolley,et al.  Ultra-high-speed DNA sequencing using capillary electrophoresis chips. , 1995, Analytical chemistry.

[4]  M. A. Northrup,et al.  Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device. , 1996, Analytical chemistry.

[5]  Champak Das,et al.  Effects of separation length and voltage on isoelectric focusing in a plastic microfluidic device , 2006, Electrophoresis.

[6]  R. Mathies,et al.  Integrated microfluidic systems for high-performance genetic analysis. , 2009, Trends in biotechnology.

[7]  Microdevice DNA forensics by the simple tandem repeat method. , 2006, Journal of chromatography. A.

[8]  Feng Xu,et al.  Polymer solutions and entropic‐based systems for double‐stranded DNA capillary electrophoresis and microchip electrophoresis , 2004, Electrophoresis.

[9]  Igor L. Medintz,et al.  Single-molecule DNA amplification and analysis in an integrated microfluidic device. , 2001, Analytical chemistry.

[10]  Jack A. M. Leunissen,et al.  Turning CFCs into salt. , 1996, Nucleic Acids Res..

[11]  R. Mathies,et al.  Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis. , 2001, Lab on a chip.

[12]  Richard A Mathies,et al.  Rapid and High‐Throughput Forensic Short Tandem Repeat Typing Using a 96‐Lane Microfabricated Capillary Array Electrophoresis Microdevice * , 2006, Journal of forensic sciences.

[13]  E. Levedakou,et al.  Characterization and validation studies of powerPlex 2.1, a nine-locus short tandem repeat (STR) multiplex system and penta D monoplex. , 2002, Journal of forensic sciences.

[14]  A. Barron,et al.  Polymeric matrices for DNA sequencing by capillary electrophoresis , 2000, Electrophoresis.

[15]  M. Scarpetta,et al.  Identification and characterization of variant alleles at CODIS STR loci. , 2005, Journal of forensic sciences.

[16]  Brian McKenna,et al.  A high‐performance multilane microdevice system designed for the DNA forensics laboratory , 2004, Electrophoresis.

[17]  Eric Buel,et al.  Forensic DNA typing by capillary electrophoresis using the ABI Prism 310 and 3100 genetic analyzers for STR analysis , 2004, Electrophoresis.

[18]  A. Barron,et al.  Influence of Polymer Concentration and Electric Field Experimental Study and Comparison with Theory , 1997 .

[19]  Lloyd M. Smith,et al.  Analysis of resolution in DNA sequencing by capillary gel electrophoresis , 1993 .

[20]  Yin Shen,et al.  The development of reduced size STR amplicons as tools for analysis of degraded DNA. , 2003, Journal of forensic sciences.

[21]  Peng Liu,et al.  Real-time forensic DNA analysis at a crime scene using a portable microchip analyzer. , 2008, Forensic science international. Genetics.

[22]  A. Woolley,et al.  High-speed DNA genotyping using microfabricated capillary array electrophoresis chips. , 1997, Analytical chemistry.

[23]  R A Mathies,et al.  Capillary electrophoresis chips with integrated electrochemical detection. , 1998, Analytical chemistry.

[24]  Benjamin E. Krenke,et al.  Validation of a 16-locus fluorescent multiplex system. , 2002, Journal of forensic sciences.

[25]  J. Butler,et al.  A study on the effects of degradation and template concentration on the amplification efficiency of the STR Miniplex primer sets. , 2004, Journal of forensic sciences.

[26]  B. McCord,et al.  The Application of Miniplex Primer Sets in the Analysis of Degraded DNA from Human Skeletal Remains * , 2006, Journal of forensic sciences.

[27]  J. Butler,et al.  Developmental Validation of Reduced‐Size STR Miniplex Primer Sets * , 2007, Journal of forensic sciences.

[28]  Eric Buel,et al.  Development of an Alu-based, real-time PCR method for quantitation of human DNA in forensic samples. , 2003, Journal of forensic sciences.

[29]  J. Butler,et al.  Mitochondrial DNA typing screens with control region and coding region SNPs. , 2005, Journal of forensic sciences.

[30]  A. Barron,et al.  DNA sequencing and genotyping in miniaturized electrophoresis systems , 2004, Electrophoresis.

[31]  L J Kricka,et al.  Evaluation of DNA fragment sizing and quantification by the agilent 2100 bioanalyzer. , 2000, Clinical chemistry.