A Bayesian View on Cryo-EM Structure Determination

Three-dimensional (3D) structure determination by single-particle analysis of cryo-electron microscopy (cryo-EM) images requires many parameters to be determined from extremely noisy data. This makes the method prone to overfitting, that is, when structures describe noise rather than signal, in particular near their resolution limit where noise levels are highest. Cryo-EM structures are typically filtered using ad hoc procedures to prevent overfitting, but the tuning of arbitrary parameters may lead to subjectivity in the results. I describe a Bayesian interpretation of cryo-EM structure determination, where smoothness in the reconstructed density is imposed through a Gaussian prior in the Fourier domain. The statistical framework dictates how data and prior knowledge should be combined, so that the optimal 3D linear filter is obtained without the need for arbitrariness and objective resolution estimates may be obtained. Application to experimental data indicates that the statistical approach yields more reliable structures than existing methods and is capable of detecting smaller classes in data sets that contain multiple different structures.

[1]  Navdeep Jaitly,et al.  A Bayesian method for 3D macromolecular structure inference using class average images from single particle electron microscopy , 2010, Bioinform..

[2]  Fred J. Sigworth,et al.  Structure of the BK potassium channel in a lipid membrane from electron cryomicroscopy , 2009, Nature.

[3]  G. Murshudov,et al.  Refinement of macromolecular structures by the maximum-likelihood method. , 1997, Acta crystallographica. Section D, Biological crystallography.

[4]  José María Carazo,et al.  Modeling experimental image formation for likelihood-based classification of electron microscopy data. , 2007, Structure.

[5]  David J. C. MacKay,et al.  Information Theory, Inference, and Learning Algorithms , 2004, IEEE Transactions on Information Theory.

[6]  R. Henderson,et al.  Optimal determination of particle orientation, absolute hand, and contrast loss in single-particle electron cryomicroscopy. , 2003, Journal of molecular biology.

[7]  Jose-Maria Carazo,et al.  An introduction to maximum-likelihood methods in cryo-EM. , 2010, Methods in enzymology.

[8]  Michael Nilges,et al.  Materials and Methods Som Text Figs. S1 to S6 References Movies S1 to S5 Inferential Structure Determination , 2022 .

[9]  Yao Cong,et al.  Single particle analysis at high resolution. , 2010, Methods in enzymology.

[10]  G. Bricogne Maximum entropy and the foundations of direct methods , 1984 .

[11]  J. Pipe,et al.  Sampling density compensation in MRI: Rationale and an iterative numerical solution , 1999, Magnetic resonance in medicine.

[12]  R Henderson,et al.  Electronic detectors for electron microscopy. , 2007, Current opinion in structural biology.

[13]  Pawel A Penczek,et al.  Three-dimensional spectral signal-to-noise ratio for a class of reconstruction algorithms. , 2002, Journal of structural biology.

[14]  N. Grigorieff,et al.  Noise bias in the refinement of structures derived from single particles. , 2004, Ultramicroscopy.

[15]  Dominika Elmlund,et al.  Ab initio structure determination from electron microscopic images of single molecules coexisting in different functional states. , 2010, Structure.

[16]  Nikolaus Grigorieff,et al.  Near-atomic resolution reconstructions of icosahedral viruses from electron cryo-microscopy. , 2011, Current opinion in structural biology.

[17]  Jitendra Malik,et al.  Automated multi-model reconstruction from single-particle electron microscopy data. , 2010, Journal of structural biology.

[18]  Gabriel C Lander,et al.  Automated cryoEM data acquisition and analysis of 284742 particles of GroEL. , 2006, Journal of structural biology.

[19]  Joachim Frank,et al.  Classification by bootstrapping in single particle methods , 2010, 2010 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[20]  J. Frank,et al.  Determination of signal-to-noise ratios and spectral SNRs in cryo-EM low-dose imaging of molecules. , 2009, Journal of structural biology.

[21]  Masafumi Yohda,et al.  ATP Binding Is Critical for the Conformational Change from an Open to Closed State in Archaeal Group II Chaperonin* , 2003, Journal of Biological Chemistry.

[22]  Conrad C. Huang,et al.  Visualizing density maps with UCSF Chimera. , 2007, Journal of structural biology.

[23]  Sjors H W Scheres,et al.  Visualizing molecular machines in action: Single-particle analysis with structural variability. , 2010, Advances in protein chemistry and structural biology.

[24]  Pawel A Penczek,et al.  Image restoration in cryo-electron microscopy. , 2010, Methods in enzymology.

[25]  W Chiu,et al.  EMAN: semiautomated software for high-resolution single-particle reconstructions. , 1999, Journal of structural biology.

[26]  José-Maria Carazo,et al.  The Fidelity of 3D Reconstructions from Incomplete Data and the Use of Restoration Methods , 1992 .

[27]  E. Orlova,et al.  Detection and separation of heterogeneity in molecular complexes by statistical analysis of their two-dimensional projections. , 2008, Journal of structural biology.

[28]  Yuhong Yang,et al.  Information Theory, Inference, and Learning Algorithms , 2005 .

[29]  R. Henderson Realizing the potential of electron cryo-microscopy , 2004, Quarterly Reviews of Biophysics.

[30]  D. Rubin,et al.  Maximum likelihood from incomplete data via the EM - algorithm plus discussions on the paper , 1977 .

[31]  G. Jensen Cryo-EM, Part A: sample preparation and data collection. Preface. , 2010 .

[32]  A T Brünger,et al.  Free R value: cross-validation in crystallography. , 1997, Methods in enzymology.

[33]  J M Carazo,et al.  XMIPP: a new generation of an open-source image processing package for electron microscopy. , 2004, Journal of structural biology.

[34]  J. Frank Three-Dimensional Electron Microscopy of Macromolecular Assemblies , 2006 .

[35]  N. Grigorieff,et al.  An adaptation of the Wiener filter suitable for analyzing images of isolated single particles. , 2011, Journal of structural biology.

[36]  Sjors H W Scheres,et al.  Classification of structural heterogeneity by maximum-likelihood methods. , 2010, Methods in enzymology.

[37]  N Grigorieff,et al.  Three-dimensional structure of bovine NADH:ubiquinone oxidoreductase (complex I) at 22 A in ice. , 1998, Journal of molecular biology.

[38]  Anchi Cheng,et al.  Automated molecular microscopy: the new Leginon system. , 2005, Journal of structural biology.

[39]  K. Nagayama,et al.  Phase plates for transmission electron microscopy. , 2010, Methods in enzymology.

[40]  José María Carazo,et al.  Image processing for electron microscopy single-particle analysis using XMIPP , 2008, Nature Protocols.

[41]  L. Norton-Wayne Computer Techniques for Image Processing in Electron Microscopy , 1979, Advances in Imaging and Electron Physics.

[42]  Nikolaus Grigorieff,et al.  FREALIGN: high-resolution refinement of single particle structures. , 2007, Journal of structural biology.