Detection of nanomolar concentrations of copper(II) with a Tb-quinoline-2-one probe using luminescence quenching or luminescence decay time.
暂无分享,去创建一个
Niko Samec | Axel Duerkop | Aleksandra Lobnik | Matejka Turel | N. Samec | A. Duerkop | A. Lobnik | M. Turel | A. Yegorova | Yulia Scripinets | Alla Yegorova | Yulia Scripinets
[1] Junwei Di,et al. A novel spectrophotometric determination of trace copper based on charge transfer complex. , 2005, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.
[2] M. Akamine,et al. Determination of transition metal irons based on quenching of the rare earth luminescence , 2003 .
[3] Carol A. Fierke,et al. Cu+- and Cu2+-sensitive PEBBLE fluorescent nanosensors using DsRed as the recognition element , 2006 .
[4] M. Cann,et al. Design, synthesis and evaluation of ratiometric probes for hydrogencarbonate based on europium emission. , 2004, Organic & biomolecular chemistry.
[5] Frederick S. Richardson,et al. Terbium(III) and europium(III) ions as luminescent probes and stains for biomolecular systems , 1982 .
[6] G. Shen,et al. A highly selective fluorescent sensor for Cu2+ based on 2-(2′-hydroxyphenyl)benzoxazole in a poly(vinyl chloride) matrix , 2006 .
[7] D. B. Hibbert,et al. Sub-ppt detection limits for copper ions with Gly-Gly-His modified electrodes. , 2001, Chemical communications.
[8] E. Anslyn,et al. Catalytic signal amplification using a Heck reaction. An example in the fluorescence sensing of CuII. , 2004, Journal of the American Chemical Society.
[9] R. Cassella. Flow injection spectrophotometric determination of copper in petroleum refinery wastewaters , 2002 .
[10] Thorfinnur Gunnlaugsson,et al. The Selectivity of Reversible Oxy-Anion Binding in Aqueous Solution at a Chiral Europium and Terbium Center: Signaling of Carbonate Chelation by Changes in the Form and Circular Polarization of Luminescence Emission , 2000 .
[11] C. Delerue-Matos,et al. Automation of iron and copper determination in milks using FIA systems and colourimetric detection , 1998 .
[12] D. Pang,et al. Luminescent CdSe-ZnS quantum dots as selective Cu2+ probe , 2004 .
[13] D. Günther,et al. A novel polymeric membrane electrode for the potentiometric analysis of Cu2+ in drinking water , 2005 .
[14] J. Olmsted. Calorimetric determinations of absolute fluorescence quantum yields , 1979 .
[15] J. Ocana,et al. Fluorescence and terbium-sensitised luminescence determination of garenoxacin in human urine and serum. , 2004, Talanta.
[16] Marian Elbanowski,et al. The lanthanides as luminescent probes in investigations of biochemical systems , 1996 .
[17] G. Yahioglu,et al. Modern bioassays using metal chelates as luminescent probes. , 1996, Natural product reports.
[18] Henryk Szmacinski,et al. Fluorescence lifetime-based sensing and imaging. , 1995, Sensors and actuators. B, Chemical.
[19] V. Losev,et al. Low-Temperature Sorption–Luminescence Determination of Copper in Natural Water Using Silica Gel Chemically Modified with Mercapto Groups , 2002 .
[20] J. Moffett,et al. Distribution of dissolved species and suspended particulate copper in an intertidal ecosystem affected by copper mine tailings in Northern Chile , 2006 .
[21] B. Tang,et al. Highly luminescent water-soluble CdTe nanowires as fluorescent probe to detect copper(II). , 2005, Chemical communications.
[22] Chen Bo,et al. A new determining method of copper(II) ions at ng ml−1 levels based on quenching of the water-soluble nanocrystals fluorescence , 2005, Analytical and bioanalytical chemistry.
[23] George A. Reynolds,et al. New coumarin dyes with rigidized structure for flashlamp-pumped dye lasers , 1975 .
[24] Jin‐Ming Lin,et al. Simultaneous Determination of Copper(II) and Cobalt(II) by Ion Chromatography Coupled with Chemiluminescent Detection , 2003, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[25] O. Wolfbeis,et al. Fluorescence Quenching of the Europium Tetracycline Hydrogen Peroxide Complex by Copper (II) and other Metal Ions , 2005, Applied spectroscopy.
[26] M. A. Kessler,et al. Determination of copper at ng ml−1-levels based on quenching of the europium chelate luminescence , 1998 .
[27] E. Diamandis,et al. Time-resolved detection of lanthanide luminescence for ultrasensitive bioanalytical assays. , 1995, Journal of photochemistry and photobiology. B, Biology.
[28] R. Alfano,et al. Effect of soap on the fluorescent lifetime and quantum yield of rhodamine 6G in water , 1973 .
[29] M. Miró,et al. Application of flowing stream techniques to water analysis Part III. Metal ions: alkaline and alkaline-earth metals, elemental and harmful transition metals, and multielemental analysis. , 2004, Talanta.
[30] Dietmar Kieslinger,et al. Luminescence lifetime-based sensing: new materials, new devices , 1997 .
[31] R. Leblanc,et al. Peptide-coated CdS quantum dots for the optical detection of copper(II) and silver(I). , 2003, Chemical communications.
[32] M. Richter,et al. Determining copper ions in water using electrochemiluminescence , 2001 .
[33] L. Capitán-Vallvey,et al. Fluorescence resonance energy transfer disposable sensor for copper(II) , 2006 .
[34] A. Minelli. BIO , 2009, Evolution & Development.
[35] Opto-electrochemical planar wave-guide sensor for copper (II) ion. , 2002, Journal of biochemical and biophysical methods.
[36] A. W. Czarnik,et al. A LONG-WAVELENGTH FLUORESCENT CHEMODOSIMETER SELECTIVE FOR CU(II) ION IN WATER , 1997 .
[37] A. Townshend. Metals and their Compounds in the Environment. Occurrence, Analysis and Biological Relevance , 1993 .
[38] J. Lin,et al. Chemiluminescence investigation of NH(2)OH-fluorescein-Cu(2+) system and its application to copper analysis in serum. , 1995, Talanta.
[39] S. Lis,et al. Energy transfer in solution of lanthanide complexes , 2002 .
[40] A. Almeida,et al. Automatic flow system for the sequential determination of copper in serum and urine by flame atomic absorption spectrometry , 2006 .
[41] S. Kolev,et al. Determination of copper in natural waters by batch and oscillating flow injection stripping potentiometry , 1996 .
[42] Ivana Murković Steinberg,et al. Characterisation of an optical sensor membrane based on the metal ion indicator Pyrocatechol Violet , 2003 .
[43] H. Sharghi,et al. Copper(II)-selective fluorimetric bulk optode membrane based on a 1-hydroxy-9,10-anthraquinone derivative having two propenyl arms as a neutral fluorogenic ionophore. , 2006, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.
[44] M. Anke,et al. Elements and their compounds in the environment , 2004 .
[45] J. Kovács,et al. Catalytic hydrolysis of esters of 2-hydroxypyridine derivatives for Cu2+ detection. , 2008, Inorganic chemistry.
[46] T. Werner,et al. Highly selective optical sensing of copper(II) ions based on fluorescence quenching of immobilised Lucifer Yellow , 2002 .
[47] F. Mancin,et al. Exploiting the Self-Assembly Strategy for the Design of Selective Cu(II) Ion Chemosensors. , 1999, Angewandte Chemie.
[48] P. Jaque,et al. Flow Injection Method for Preconcentration and Polarographic Determination of Copper in Water , 2000 .
[49] Hui-Hui Zeng,et al. Real-time determination of picomolar free Cu(II) in seawater using a fluorescence-based fiber optic biosensor. , 2003, Analytical chemistry.
[50] Zhihong Lin,et al. A europium-ion-based luminescent sensing probe for hydrogen peroxide. , 2002, Angewandte Chemie.
[51] R. Cassella,et al. Synthesis and application of a functionalized resin for flow injection/F AAS copper determination in waters. , 2005, Talanta.
[52] M. Gholivand,et al. Characterization of an optical copper sensor based on N,N'-bis(salycilidene)-1,2-phenylenediamine , 2005 .
[53] J. Lakowicz. Principles of fluorescence spectroscopy , 1983 .
[54] J. Buffle,et al. Speciation of Cu(II) with a flow-through permeation liquid membrane: discrimination between free copper, labile and inert Cu(II) complexes, under natural water conditions. , 2008, The Analyst.
[55] Raoul Kopelman,et al. DsRed as a highly sensitive, selective, and reversible fluorescence-based biosensor for both Cu(+) and Cu(2+) ions. , 2006, Biosensors & bioelectronics.
[56] Sonja Draxler,et al. Luminescence decay-time-based optical sensors: principles and problems , 1993 .