Detection of nanomolar concentrations of copper(II) with a Tb-quinoline-2-one probe using luminescence quenching or luminescence decay time.

We present a time-resolved (gated) luminescence-based method for determination of Cu2+ ions in microtiterplate format in the nanomolar concentration range using the novel long-lived terbium-[1-methyl-4-hydroxy-3-(N-2-ethyl-5-aminothiadiazolyl-)-carbamoyl-quinoline-2-one] (TbL) complex. The probe works best in Tb:L = 1:2 stoichiometry at neutral pH. The dynamic range is from 10 to 300 nmol L(-1) of Cu2+ and the limit of detection is 4.3 nmol L(-1). This is the lowest limit of detection achieved so far for luminescent lanthanide-based probes for copper. It is shown that gating can efficiently suppress intense, short decaying background fluorescence e.g. that of Rhodamine 6G. The assay can be performed by measurement of luminescence decay time, as well. Stern-Volmer studies indicate that static quenching dominates over dynamic quenching. TbL2 was tested for the effect of some relevant interferents and the assay was applied to the determination of copper in tap water samples. The results achieved were in good agreement with those of a reference method.

[1]  Junwei Di,et al.  A novel spectrophotometric determination of trace copper based on charge transfer complex. , 2005, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[2]  M. Akamine,et al.  Determination of transition metal irons based on quenching of the rare earth luminescence , 2003 .

[3]  Carol A. Fierke,et al.  Cu+- and Cu2+-sensitive PEBBLE fluorescent nanosensors using DsRed as the recognition element , 2006 .

[4]  M. Cann,et al.  Design, synthesis and evaluation of ratiometric probes for hydrogencarbonate based on europium emission. , 2004, Organic & biomolecular chemistry.

[5]  Frederick S. Richardson,et al.  Terbium(III) and europium(III) ions as luminescent probes and stains for biomolecular systems , 1982 .

[6]  G. Shen,et al.  A highly selective fluorescent sensor for Cu2+ based on 2-(2′-hydroxyphenyl)benzoxazole in a poly(vinyl chloride) matrix , 2006 .

[7]  D. B. Hibbert,et al.  Sub-ppt detection limits for copper ions with Gly-Gly-His modified electrodes. , 2001, Chemical communications.

[8]  E. Anslyn,et al.  Catalytic signal amplification using a Heck reaction. An example in the fluorescence sensing of CuII. , 2004, Journal of the American Chemical Society.

[9]  R. Cassella Flow injection spectrophotometric determination of copper in petroleum refinery wastewaters , 2002 .

[10]  Thorfinnur Gunnlaugsson,et al.  The Selectivity of Reversible Oxy-Anion Binding in Aqueous Solution at a Chiral Europium and Terbium Center: Signaling of Carbonate Chelation by Changes in the Form and Circular Polarization of Luminescence Emission , 2000 .

[11]  C. Delerue-Matos,et al.  Automation of iron and copper determination in milks using FIA systems and colourimetric detection , 1998 .

[12]  D. Pang,et al.  Luminescent CdSe-ZnS quantum dots as selective Cu2+ probe , 2004 .

[13]  D. Günther,et al.  A novel polymeric membrane electrode for the potentiometric analysis of Cu2+ in drinking water , 2005 .

[14]  J. Olmsted Calorimetric determinations of absolute fluorescence quantum yields , 1979 .

[15]  J. Ocana,et al.  Fluorescence and terbium-sensitised luminescence determination of garenoxacin in human urine and serum. , 2004, Talanta.

[16]  Marian Elbanowski,et al.  The lanthanides as luminescent probes in investigations of biochemical systems , 1996 .

[17]  G. Yahioglu,et al.  Modern bioassays using metal chelates as luminescent probes. , 1996, Natural product reports.

[18]  Henryk Szmacinski,et al.  Fluorescence lifetime-based sensing and imaging. , 1995, Sensors and actuators. B, Chemical.

[19]  V. Losev,et al.  Low-Temperature Sorption–Luminescence Determination of Copper in Natural Water Using Silica Gel Chemically Modified with Mercapto Groups , 2002 .

[20]  J. Moffett,et al.  Distribution of dissolved species and suspended particulate copper in an intertidal ecosystem affected by copper mine tailings in Northern Chile , 2006 .

[21]  B. Tang,et al.  Highly luminescent water-soluble CdTe nanowires as fluorescent probe to detect copper(II). , 2005, Chemical communications.

[22]  Chen Bo,et al.  A new determining method of copper(II) ions at ng ml−1 levels based on quenching of the water-soluble nanocrystals fluorescence , 2005, Analytical and bioanalytical chemistry.

[23]  George A. Reynolds,et al.  New coumarin dyes with rigidized structure for flashlamp-pumped dye lasers , 1975 .

[24]  Jin‐Ming Lin,et al.  Simultaneous Determination of Copper(II) and Cobalt(II) by Ion Chromatography Coupled with Chemiluminescent Detection , 2003, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[25]  O. Wolfbeis,et al.  Fluorescence Quenching of the Europium Tetracycline Hydrogen Peroxide Complex by Copper (II) and other Metal Ions , 2005, Applied spectroscopy.

[26]  M. A. Kessler,et al.  Determination of copper at ng ml−1-levels based on quenching of the europium chelate luminescence , 1998 .

[27]  E. Diamandis,et al.  Time-resolved detection of lanthanide luminescence for ultrasensitive bioanalytical assays. , 1995, Journal of photochemistry and photobiology. B, Biology.

[28]  R. Alfano,et al.  Effect of soap on the fluorescent lifetime and quantum yield of rhodamine 6G in water , 1973 .

[29]  M. Miró,et al.  Application of flowing stream techniques to water analysis Part III. Metal ions: alkaline and alkaline-earth metals, elemental and harmful transition metals, and multielemental analysis. , 2004, Talanta.

[30]  Dietmar Kieslinger,et al.  Luminescence lifetime-based sensing: new materials, new devices , 1997 .

[31]  R. Leblanc,et al.  Peptide-coated CdS quantum dots for the optical detection of copper(II) and silver(I). , 2003, Chemical communications.

[32]  M. Richter,et al.  Determining copper ions in water using electrochemiluminescence , 2001 .

[33]  L. Capitán-Vallvey,et al.  Fluorescence resonance energy transfer disposable sensor for copper(II) , 2006 .

[34]  A. Minelli BIO , 2009, Evolution & Development.

[35]  Opto-electrochemical planar wave-guide sensor for copper (II) ion. , 2002, Journal of biochemical and biophysical methods.

[36]  A. W. Czarnik,et al.  A LONG-WAVELENGTH FLUORESCENT CHEMODOSIMETER SELECTIVE FOR CU(II) ION IN WATER , 1997 .

[37]  A. Townshend Metals and their Compounds in the Environment. Occurrence, Analysis and Biological Relevance , 1993 .

[38]  J. Lin,et al.  Chemiluminescence investigation of NH(2)OH-fluorescein-Cu(2+) system and its application to copper analysis in serum. , 1995, Talanta.

[39]  S. Lis,et al.  Energy transfer in solution of lanthanide complexes , 2002 .

[40]  A. Almeida,et al.  Automatic flow system for the sequential determination of copper in serum and urine by flame atomic absorption spectrometry , 2006 .

[41]  S. Kolev,et al.  Determination of copper in natural waters by batch and oscillating flow injection stripping potentiometry , 1996 .

[42]  Ivana Murković Steinberg,et al.  Characterisation of an optical sensor membrane based on the metal ion indicator Pyrocatechol Violet , 2003 .

[43]  H. Sharghi,et al.  Copper(II)-selective fluorimetric bulk optode membrane based on a 1-hydroxy-9,10-anthraquinone derivative having two propenyl arms as a neutral fluorogenic ionophore. , 2006, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[44]  M. Anke,et al.  Elements and their compounds in the environment , 2004 .

[45]  J. Kovács,et al.  Catalytic hydrolysis of esters of 2-hydroxypyridine derivatives for Cu2+ detection. , 2008, Inorganic chemistry.

[46]  T. Werner,et al.  Highly selective optical sensing of copper(II) ions based on fluorescence quenching of immobilised Lucifer Yellow , 2002 .

[47]  F. Mancin,et al.  Exploiting the Self-Assembly Strategy for the Design of Selective Cu(II) Ion Chemosensors. , 1999, Angewandte Chemie.

[48]  P. Jaque,et al.  Flow Injection Method for Preconcentration and Polarographic Determination of Copper in Water , 2000 .

[49]  Hui-Hui Zeng,et al.  Real-time determination of picomolar free Cu(II) in seawater using a fluorescence-based fiber optic biosensor. , 2003, Analytical chemistry.

[50]  Zhihong Lin,et al.  A europium-ion-based luminescent sensing probe for hydrogen peroxide. , 2002, Angewandte Chemie.

[51]  R. Cassella,et al.  Synthesis and application of a functionalized resin for flow injection/F AAS copper determination in waters. , 2005, Talanta.

[52]  M. Gholivand,et al.  Characterization of an optical copper sensor based on N,N'-bis(salycilidene)-1,2-phenylenediamine , 2005 .

[53]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[54]  J. Buffle,et al.  Speciation of Cu(II) with a flow-through permeation liquid membrane: discrimination between free copper, labile and inert Cu(II) complexes, under natural water conditions. , 2008, The Analyst.

[55]  Raoul Kopelman,et al.  DsRed as a highly sensitive, selective, and reversible fluorescence-based biosensor for both Cu(+) and Cu(2+) ions. , 2006, Biosensors & bioelectronics.

[56]  Sonja Draxler,et al.  Luminescence decay-time-based optical sensors: principles and problems , 1993 .