Novel Dexterity Kit Concept Based on a Review of Hand Dexterity Literature

Dexterity is commonly defined by the quality of fine, voluntary movements used to manipulate objects during a specific task involving the movement of wrist, hands, arm, and fingers. Dexterity assessment kits are used to determine a person’s skilled task abilities through performance parameters such as speed, accuracy, and precision. This study proposes that one parameter that is as critical as the traditionally measured parameters is finger strength which could be measured as the amount of force or effort that a human hand exerts during object manipulation through fingers. In this paper, a detailed literature review was conducted of the traditional dexterity assessment methods and their kits used in the past. Thereafter, a novel dexterity kit has been proposed which incorporates measurement of finger strength data in addition to the traditional dexterity parameters during hand dexterity assessment. An experiment suggested that a significantly greater finger force is required for peg manipulation in the new test kit than in the traditional one.

[1]  Earl D. Sharp MAXIMUM TORQUE EXERTABLE ON KNOBS OF VARIOUS SIZES AND RIM SURFACES , 1962 .

[2]  J. Thornby,et al.  Measuring normal hand dexterity values in normal 3-, 4-, and 5-year-old children and their relationship with grip and pinch strength. , 2003, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[3]  Virgil Mathiowetz,et al.  Test-retest reliability of the Purdue Pegboard for persons with multiple sclerosis. , 2003, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[4]  Alaster Yoxall,et al.  Measure for Measure: Pack Performance versus Human Dexterity and Grip Strength , 2017 .

[5]  R. H. Jebsen,et al.  An objective and standardized test of hand function. , 1969, Archives of physical medicine and rehabilitation.

[6]  V. Mathiowetz,et al.  Adult norms for the Box and Block Test of manual dexterity. , 1985, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[7]  Monique A M Berger,et al.  Task specificity of finger dexterity tests. , 2009, Applied ergonomics.

[8]  Mark E. Williams,et al.  Manual ability as a marker of dependency in geriatric women. , 1982, Journal of chronic diseases.

[9]  A A Amis,et al.  Variation of finger forces in maximal isometric grasp tests on a range of cylinder diameters. , 1987, Journal of biomedical engineering.

[10]  E. Moberg,et al.  Objective methods for determining the functional value of sensibility in the hand. , 1958, The Journal of bone and joint surgery. British volume.

[11]  D. Aaron,et al.  Development of the Functional Dexterity Test (FDT): construction, validity, reliability, and normative data. , 2003, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[12]  Catherine L. Backman,et al.  Assessment of Hand Function: The Relationship between Pegboard Dexterity and Applied Dexterity , 1992 .

[13]  V. Mathiowetz,et al.  Adult Norms for the Nine Hole Peg Test of Finger Dexterity , 1985 .

[14]  J. Desrosiers,et al.  The Minnesota Manual Dexterity Test: Reliability, Validity and Reference Values Studies with Healthy Elderly People , 1997 .

[15]  E A FLEISHMAN,et al.  Testing for psychomotor abilities by means of apparatus tests. , 1953, Psychological bulletin.

[16]  I. Shimoyama,et al.  The finger-tapping test. A quantitative analysis. , 1990, Archives of neurology.

[17]  Gloria R. Gogola,et al.  Innovative evaluation of dexterity in pediatrics. , 2015, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[18]  Yong-Ku Kong,et al.  Optimal cylindrical handle diameter for grip force tasks , 2005 .