Iodinated contrast media: effect of osmolarity and injection temperature on erythrocyte morphology in vitro

Background: Some side effects of intravenously injected iodinated contrast media are thought to be linked to the biological properties of the various agents and their effect on blood components. Purpose: To assess the effect of osmolarity and injection temperature of iodinated contrast media on erythrocyte (RBC) morphology in vitro. Material and Methods: Blood from 20 volunteers was incubated with three different contrast media (320 mg I/ml iso-osmolar iodixanol, 300 mg I/ml low-osmolar iopromide, 300 mg I/ml low-osmolar iopamidol) injected at 37°C, 43°C, and 48°C, and in two different volumes corresponding to the estimated concentration at the site of venous injection and after systemic distribution. After 10 min incubation, aliquots were removed for complete blood count analysis and blood smears. Two hematologists blindedly and independently reviewed all smears, and determined the grade of morphological RBC changes compared to a blank sample. Results: There was excellent (κ = 0.98) inter-reader correlation for grading RBC changes. At systemic concentration at 37°C, the grade of RBC changes was significantly (P<0.05) less in blood samples exposed to iso-osmolar iodixanol (mean 0.21) as compared to low-osmolar iopromide (mean 0.26) and low-osmolar iopamidol (mean 0.58). These differences became more significant at higher volumes, corresponding to concentrations at the site of injection and higher injection temperatures. Conclusion: In vitro, RBC morphology is less affected by iso-osmolar as compared to low-osmolar contrast media. These differences become more significant at higher injection temperatures that are proposed to improve flow dynamics for high-speed injection.

[1]  V. Lorusso,et al.  Effects of iodinated contrast media on endothelium: An in vitro study. , 2007, Toxicology in vitro : an international journal published in association with BIBRA.

[2]  J. Jakobsen Renal experience with Visipagne , 2006, European Radiology.

[3]  N. Pugh Haemodynamic and rheological effects of contrast media: the role of viscosity and osmolality , 2006, European Radiology.

[4]  P. Aspelin,et al.  Effects of iodinated contrast media on blood and endothelium , 2006, European Radiology.

[5]  S. Silverman,et al.  Universal use of nonionic iodinated contrast medium for CT: evaluation of safety in a large urban teaching hospital. , 2005, AJR. American journal of roentgenology.

[6]  R. Felix,et al.  Jodeinbringungsgeschwindigkeit verschieden konzentrierter Röntgenkontrastmittel bei schneller intravenöser Injektion , 2004 .

[7]  Kathryn E. McGoldrick,et al.  Nephrotoxic Effects in High-Risk Patients Undergoing Angiography , 2004 .

[8]  F. Knollmann,et al.  [Iodine delivery rate of different concentrations of iodine-containing contrast agents with rapid injection]. , 2004, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[9]  R. de Caterina,et al.  Vasomotor effects of iodinated contrast media: just side effects? , 2003, Current vascular pharmacology.

[10]  J. Ventre,et al.  Comparison of the effects of radiographic contrast media on dehydration and filterability of red blood cells from donors homozygous for hemoglobin A or hemoglobin S , 2001, American journal of hematology.

[11]  H. Thomsen,et al.  Adverse reactions to iodinated contrast media , 2001, European Radiology.

[12]  J. Muhlestein,et al.  Randomized trial of contrast media utilization in high-risk PTCA: the COURT trial. , 2000, Circulation.

[13]  A. Romano,et al.  Anaphylactoid and anaphylactic reactions to iodinated contrast material , 1999, Allergy.

[14]  J. Dufaux,et al.  Effects of Contrast Media on Blood Rheology: Comparison in Humans, Pigs, and Sheep , 1999, CardioVascular and Interventional Radiology.

[15]  Y. Katayama,et al.  Heat and pain sensations induced by arterial injection of low-osmolality contrast media: a comparison of patients' discomfort with ionic saline, nonionic glucose, and vasodilator nitrate. , 1996, Academic radiology.

[16]  K. Sakariassen,et al.  Effects of Ionic and Nonionic Contrast Media on Endothelium and on Arterial Thrombus Formation , 1996, Acta radiologica.

[17]  H. Schieffer,et al.  Influence of a Non-Ionic Radiography Contrast Medium on the Microcirculation , 1996, Acta radiologica.

[18]  J. Jakobsen Renal experience with Visipaque. , 1996, European radiology.

[19]  M. Knopp,et al.  [Effects of viscosity, cannula size and temperature in mechanical contrast media administration in CT and magnetic resonance tomography]. , 1995, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[20]  B. Bolstad,et al.  Main Results of the First Comparative Clinical Studies on Visipaque , 1995, Acta radiologica. Supplementum.

[21]  K. Dyrstad,et al.  Relationship between Viscosity and Determined Injection Pressure in Angiography Catheters for Common Roentgen Contrast Media , 1995, Acta radiologica. Supplementum.

[22]  A. Goodall,et al.  Profound Platelet Degranulation Is an Important Side Effect of Some Types of Contrast Media Used in Interventional Cardiology , 1993, Circulation.

[23]  D. Lerche,et al.  The effects of different ionic and non-ionic X-ray contrast media on the morphological and rheological properties of human red blood cells , 1992 .

[24]  M. Hardeman,et al.  The effect of low-osmolar ionic and nonionic contrast media on human blood viscosity, erythrocyte morphology, and aggregation behavior. , 1991, Investigative radiology.

[25]  G. Nash,et al.  Effect of dehydration on the viscoelastic behavior of red cells. , 1991, Blood cells.

[26]  C. Corot,et al.  Contrast media for angiography: physicochemical properties, pharmacokinetics and biocompatibility. , 1991, Clinical materials.

[27]  P. Aspelin,et al.  Effect of four non-ionic contrast media on red blood cells in vitro. I. Morphology. , 1987, Acta radiologica. Supplementum.

[28]  P. Aspelin,et al.  Effect of four non-ionic contrast media on red blood cells in vitro. III. Deformability. , 1987, Acta radiologica. Supplementum.

[29]  P. Dawson,et al.  Effect of contrast media on red cell filtrability and morphology. , 1983, The British journal of radiology.

[30]  F. Laerum Acute damage to human endothelial cells by brief exposure to contrast media in vitro. , 1983, Radiology.

[31]  P. Aspelin,et al.  Effect of Iohexol on Red Cell Deformability in Vitro , 1980, Acta radiologica. Supplementum.

[32]  P. Aspelin,et al.  Effect of iohexol on human erythrocytes. II. Red cell aggregation in vitro. , 1980, Acta radiologica. Supplementum.

[33]  P. Aspelin,et al.  Effect of iohexol on human erythrocytes. I. Changes of red cell morphology in vitro. , 1980, Acta radiologica. Supplementum.

[34]  P. Aspelin Effect of Ionic and Non-Ionic Contrast Media on Whole Blood Viscosity, Plasma Viscosity and Hematocrit in Vitro , 1978, Acta radiologica: diagnosis.

[35]  P. Aspelin Effect of Ionic and Non-Ionic Contrast Media on Morphology of Human Erythrocytes , 1978, Acta radiologica: diagnosis.

[36]  H. Chaplin,et al.  Changes in human red blood cells during in vitro exposure to several roentgenologic contrast media. , 1961, The American journal of roentgenology, radium therapy, and nuclear medicine.