Measurement of δ18O, δ17O, and 17O-excess in water by off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry.

Stable isotopes of water have long been used to improve understanding of the hydrological cycle, catchment hydrology, and polar climate. Recently, there has been increasing interest in measurement and use of the less-abundant (17)O isotope in addition to (2)H and (18)O. Off-axis integrated cavity output spectroscopy (OA-ICOS) is demonstrated for accurate and precise measurements δ(18)O, δ(17)O, and (17)O-excess in liquid water. OA-ICOS involves no sample conversion and has a small footprint, allowing measurements to be made by researchers collecting the samples. Repeated (514) high-throughput measurements of the international isotopic reference water standard Greenland Ice Sheet Precipitation (GISP) demonstrate the precision and accuracy of OA-ICOS: δ(18)OVSMOW-SLAP = -24.74 ± 0.07‰ (1σ) and δ(17)OVSMOW-SLAP = -13.12 ± 0.05‰ (1σ). For comparison, the International Atomic Energy Agency (IAEA) value for δ(18)OVSMOW-SLAP is -24.76 ± 0.09‰ (1σ) and an average of previously reported values for δ(17)OVSMOW-SLAP is -13.12 ± 0.06‰ (1σ). Multiple (26) high-precision measurements of GISP provide a (17)O-excessVSMOW-SLAP of 23 ± 10 per meg (1σ); an average of previously reported values for (17)O-excessVSMOW-SLAP is 22 ± 11 per meg (1σ). For all these OA-ICOS measurements, precision can be further enhanced by additional averaging. OA-ICOS measurements were compared with two independent isotope ratio mass spectrometry (IRMS) laboratories and shown to have comparable accuracy and precision as the current fluorination-IRMS techniques in δ(18)O, δ(17)O, and (17)O-excess. The ability to measure accurately δ(18)O, δ(17)O, and (17)O-excess in liquid water inexpensively and without sample conversion is expected to increase vastly the application of δ(17)O and (17)O-excess measurements for scientific understanding of the water cycle, atmospheric convection, and climate modeling among others.

[1]  J. Barth,et al.  Optimization of instrument setup and post‐run corrections for oxygen and hydrogen stable isotope measurements of water by isotope ratio infrared spectroscopy (IRIS) , 2012 .

[2]  Noah,et al.  Limnology and Oceanography. , 1961, Science.

[3]  E. Barkan,et al.  Diffusivity fractionations of H216O/H217O and H216O/ H218O in air and their implications for isotope hydrology , 2007 .

[4]  P. Baertschi Absolute18O content of standard mean ocean water , 1976 .

[5]  J. McDonnell,et al.  Isotope tracers in catchment hydrology , 1998 .

[6]  J. Jouzel,et al.  Glacial–interglacial changes in ocean surface conditions in the Southern Hemisphere , 1999, Nature.

[7]  B. M. A. A. Verstappen-Dumoulin,et al.  Doubly Labelled Water analysis: preparation, memory correction, calibration and quality assurance for δ2H and δ18O measurements over four orders of magnitudes. , 2013, Rapid communications in mass spectrometry : RCM.

[8]  S. Bony,et al.  Combined measurements of 17Oexcess and d-excess in African monsoon precipitation: Implications for evaluating convective parameterizations , 2010 .

[9]  Jeffrey J. McDonnell,et al.  High‐frequency field‐deployable isotope analyzer for hydrological applications , 2009 .

[10]  D. Yakir,et al.  The triple isotopic composition of oxygen in leaf water , 2006 .

[11]  J. Jouzel,et al.  Interannual variation of water isotopologues at Vostok indicates a contribution from stratospheric water vapor , 2013, Proceedings of the National Academy of Sciences.

[12]  J. Gat,et al.  Atmospheric water balance in the Amazon basin: An isotopic evapotranspiration model , 1991 .

[13]  Reference Sheet for International Measurement Standards , 2007 .

[14]  T. Brockwell,et al.  On-line high-precision stable hydrogen isotopic analyses on nanoliter water samples. , 2001, Analytical chemistry.

[15]  A. Schilt,et al.  Orbital and Millennial Antarctic Climate Variability over the Past 800,000 Years , 2007, Science.

[16]  D. W. Allan,et al.  Statistics of atomic frequency standards , 1966 .

[17]  E. Barkan,et al.  Variations of 17O/16O and 18O/16O in meteoric waters , 2010 .

[18]  A. Schauer,et al.  Measurement of SLAP2 and GISP δ17O and proposed VSMOW-SLAP normalization for δ17O and 17O(excess). , 2013, Rapid communications in mass spectrometry : RCM.

[19]  W. Dansgaard Stable isotopes in precipitation , 1964 .

[20]  Zhongfang Liu,et al.  Water balance model for mean annual hydrogen and oxygen isotope distributions in surface waters of the contiguous United States , 2011 .

[21]  L. Wassenaar,et al.  High-precision laser spectroscopy D/H and 18O/16O measurements of microliter natural water samples. , 2008, Analytical chemistry.

[22]  R. Clayton,et al.  Calibration of delta(17)O and delta(18)O of international measurement standards - VSMOW, VSMOW2, SLAP, and SLAP2. , 2010, Rapid communications in mass spectrometry : RCM.

[23]  N. Cozzarelli PNAS Early Edition. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[24]  G. Strauch,et al.  Isotopes in Environmental and Health Studies , 2006 .

[25]  Harro A. J. Meijer,et al.  The use of electrolysis for accurate delta O-17 and delta O-18 isotope measurements in water , 1998 .

[26]  E. Barkan,et al.  High precision measurements of 17O/16O and 18O/16O ratios in H2O. , 2005, Rapid communications in mass spectrometry : RCM.

[27]  J. B. Paul,et al.  Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopy , 2002 .

[28]  C. Pillinger,et al.  A technique for the determination of 18O/16O and 17O/16O isotopic ratios in water from small liquid and solid samples. , 2002, Analytical chemistry.

[29]  M. Gröning Improved water δ2H and δ18O calibration and calculation of measurement uncertainty using a simple software tool. , 2011, Rapid communications in mass spectrometry : RCM.