On the use of multi-dimensional scaling and electromagnetic tracking in high dose rate brachytherapy

High dose rate brachytherapy affords a frequent reassurance of the precise dwell positions of the radiation source. The current investigation proposes a multi-dimensional scaling transformation of both data sets to estimate dwell positions without any external reference. Furthermore, the related distributions of dwell positions are characterized by uni-or bi-modal heavy-tailed distributions. The latter are well represented by α-stable distributions. The newly proposed data analysis provides dwell position deviations with high accuracy, and, furthermore, offers a convenient visualization of the actual shapes of the catheters which guide the radiation source during the treatment.

[1]  Christoph Bert,et al.  OC-0251: Electromagnetic tracking for error detection in interstitial brachytherapy , 2016 .

[2]  Ehsan Dehghan,et al.  Electromagnetic tracking for catheter reconstruction in ultrasound-guided high-dose-rate brachytherapy of the prostate. , 2014, Brachytherapy.

[3]  A. V. D. Vaart,et al.  Asymptotic Statistics: Frontmatter , 1998 .

[4]  Bradley Beeksma,et al.  Source tracking and quality assurance of high dose rate (HDR) brachytherapy , 2014 .

[5]  D. Buckle Bayesian Inference for Stable Distributions , 1995 .

[6]  J. Michael Fitzpatrick,et al.  Iterative solution for rigid-body point-based registration with anisotropic weighting , 2009, Medical Imaging.

[7]  C. Kirisits,et al.  Magnetic resonance image guided brachytherapy. , 2014, Seminars in radiation oncology.

[8]  Christoph Bert,et al.  Electromagnetic tracking (EMT) technology for improved treatment quality assurance in interstitial brachytherapy , 2017, Journal of applied clinical medical physics.

[9]  Richard Pötter,et al.  5-year results of accelerated partial breast irradiation using sole interstitial multicatheter brachytherapy versus whole-breast irradiation with boost after breast-conserving surgery for low-risk invasive and in-situ carcinoma of the female breast: a randomised, phase 3, non-inferiority trial , 2016, The Lancet.

[10]  S. Coles,et al.  An Introduction to Statistical Modeling of Extreme Values , 2001 .

[11]  Jun Zhou,et al.  Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: a preliminary performance study. , 2013, Medical physics.

[12]  Vibeke N. Hansen,et al.  Commissioning and implementation of a stereotactic conformal radiotherapy technique using a general‐purpose planning system , 2004, Journal of applied clinical medical physics.

[13]  Marco J. Lombardi Bayesian inference for α-stable distributions: A random walk MCMC approach , 2007 .

[14]  Jon A. Wellner,et al.  Weak Convergence and Empirical Processes: With Applications to Statistics , 1996 .

[15]  Wolfgang Birkfellner,et al.  Electromagnetic Tracking in Medicine—A Review of Technology, Validation, and Applications , 2014, IEEE Transactions on Medical Imaging.

[16]  P. Jursinic Quality assurance measurements for high‐dose‐rate brachytherapy without film , 2014, Journal of applied clinical medical physics.

[17]  Andrew D. Wiles,et al.  Improved Method for Point-Based Tracking , 2010, MICCAI.

[18]  Daniel A. Bassano,et al.  A dwell position verification method for high dose rate brachytherapy , 2004, Journal of applied clinical medical physics.

[19]  Andras Lasso,et al.  Measurement of electromagnetic tracking error in a navigated breast surgery setup , 2016, SPIE Medical Imaging.

[20]  Christoph Bert,et al.  Assessment of the Implant Geometry in Fractionated Interstitial HDR Breast Brachytherapy , 2016 .

[21]  Andriy Myronenko,et al.  Point Set Registration: Coherent Point Drift , 2009, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[22]  Diego P. Ruiz,et al.  Modelling with mixture of symmetric stable distributions using Gibbs sampling , 2010, Signal Process..

[23]  Robert A Cormack,et al.  A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization. , 2014, Medical physics.

[24]  Volodymyr V. Kindratenko,et al.  A survey of electromagnetic position tracker calibration techniques , 2005, Virtual Reality.

[25]  P. M. Hartigan,et al.  Computation of the Dip Statistic to Test for Unimodality , 1985 .

[26]  Jun Zhou,et al.  Review of advanced catheter technologies in radiation oncology brachytherapy procedures , 2015, Cancer management and research.

[27]  Diego P. Ruiz,et al.  Finite mixture of alpha Stable distributions , 2007 .

[28]  J. Hartigan,et al.  The Dip Test of Unimodality , 1985 .

[29]  Juan Manuel Górriz,et al.  Bayesian Segmentation of Magnetic Resonance Images Using the α-Stable Distribution , 2011, HAIS.

[30]  Christian M Langton,et al.  Accelerated Partial Breast Irradiation (APBI): A review of available techniques , 2010, Radiation oncology.

[31]  Christopher K. I. Williams On a Connection between Kernel PCA and Metric Multidimensional Scaling , 2004, Machine Learning.

[32]  Christoph Bert,et al.  Electromagnetic tracking for treatment verification in interstitial brachytherapy , 2016, Journal of contemporary brachytherapy.

[33]  Hugh F. Durrant-Whyte,et al.  Simultaneous localization and mapping: part I , 2006, IEEE Robotics & Automation Magazine.

[34]  Luc Beaulieu,et al.  Comparison of dose and catheter optimization algorithms in prostate high-dose-rate brachytherapy. , 2016, Brachytherapy.

[35]  Gabor Fichtinger,et al.  Simultaneous Electromagnetic Tracking and Calibration for Dynamic Field Distortion Compensation , 2016, IEEE Transactions on Biomedical Engineering.

[36]  Elmar Wolfgang Lang,et al.  Unsupervised feature extraction via kernel subspace techniques , 2011, Neurocomputing.